In a large-scale radiation event, thousands may be exposed to unknown amounts of radiation, some of which may be life-threatening without immediate attention. In such situations, a method to quickly and reliably estimate dose would help medical responders triage victims to receive life-saving care. We developed such a method using electron paramagnetic resonance (EPR) to make in vivo measurements of the maxillary incisors.
View Article and Find Full Text PDFRadiat Prot Dosimetry
December 2016
Testing and verification are an integral part of any cycle to design, manufacture and improve a novel device intended for use in humans. In the case of testing Dartmouth's electron paramagnetic resonance (EPR) in vivo tooth dosimetry device, in vitro studies are needed throughout its development to test its performance, i.e.
View Article and Find Full Text PDFPlanning and preparation for a large-scale nuclear event would be advanced by assessing the applicability of potentially available bio-dosimetry methods. Using an updated comparative framework the performance of six bio-dosimetry methods was compared for five different population sizes (100-1,000,000) and two rates for initiating processing of the marker (15 or 15,000 people per hour) with four additional time windows. These updated factors are extrinsic to the bio-dosimetry methods themselves but have direct effects on each method's ability to begin processing individuals and the size of the population that can be accommodated.
View Article and Find Full Text PDFIn order to meet the potential need for emergency large-scale retrospective radiation biodosimetry following an accident or attack, we have developed instrumentation and methodology for in vivo electron paramagnetic resonance spectroscopy to quantify concentrations of radiation-induced radicals within intact teeth. This technique has several very desirable characteristics for triage, including independence from confounding biologic factors, a non-invasive measurement procedure, the capability to make measurements at any time after the event, suitability for use by non-expert operators at the site of an event, and the ability to provide immediate estimates of individual doses. Throughout development there has been a particular focus on the need for a deployable system, including instrumental requirements for transport and field use, the need for high throughput, and use by minimally trained operators.
View Article and Find Full Text PDFBACKGROUND: To prepare for a possible major radiation disaster involving large numbers of potentially exposed people, it is important to be able to rapidly and accurately triage people for treatment or not, factoring in the likely conditions and available resources. To date, planners have had to create guidelines for triage based on methods for estimating dose that are clinically available and which use evidence extrapolated from unrelated conditions. Current guidelines consequently focus on measuring clinical symptoms (e.
View Article and Find Full Text PDFPurpose: The ability to estimate individual exposures to radiation following a large attack or incident has been identified as a necessity for rational and effective emergency medical response. In vivo electron paramagnetic resonance (EPR) spectroscopy of tooth enamel has been developed to meet this need.
Materials And Methods: A novel transportable EPR spectrometer, developed to facilitate tooth dosimetry in an emergency response setting, was used to measure upper incisors in a model system, in unirradiated subjects, and in patients who had received total body doses of 2 Gy.
A catastrophic event such as a nuclear device detonation in a major U.S. city would cause a mass casualty with millions affected.
View Article and Find Full Text PDFThere is growing awareness of the need for methodologies that can be used retrospectively to provide the biodosimetry needed to carry out screening and triage immediately after an event in which large numbers of people have potentially received clinically significant doses of ionizing radiation. The general approach to developing such methodologies has been a technology centric one, often ignoring the system integrations considerations that are key to their effective use. In this study an integrative approach for the evaluation and development of a physical biodosimetry technology was applied based on in vivo electron paramagnetic resonance (EPR) dosimetry.
View Article and Find Full Text PDFFew natural disasters or intentional acts of war or terrorism have the potential for such severe impact upon a population and infrastructure as the intentional detonation of a nuclear device within a major U.S. city.
View Article and Find Full Text PDFRecognition is growing regarding the possibility that terrorism or large-scale accidents could result in potential radiation exposure of hundreds of thousands of people and that the present guidelines for evaluation after such an event are seriously deficient. Therefore, there is a great and urgent need for after-the-fact biodosimetric methods to estimate radiation dose. To accomplish this goal, the dose estimates must be at the individual level, timely, accurate, and plausibly obtained in large-scale disasters.
View Article and Find Full Text PDF