IEEE Trans Radiat Plasma Med Sci
September 2023
The HyPET project proposes a hybrid dedicated TOF-PET for prostate imaging, with pixelated detector blocks in the front layer and monolithic blocks in the back layer. In this work, four detector configurations have been experimentally evaluated for the rear detector layer. The detector configuration consists of LYSO monolithic blocks with the same size (25.
View Article and Find Full Text PDFBiomedical research has long relied on small-animal studies to elucidate disease process and develop new medical treatments. The introduction of in vivo functional imaging technology, such as PET, has allowed investigators to peer inside their subjects and follow disease progression longitudinally as well as improve understanding of normal biological processes. Recent developments in CRISPR, immuno-PET, and high-resolution in vivo imaging have only increased the importance of small-animal, or preclinical, PET imaging.
View Article and Find Full Text PDFProviding method descriptions that are more detailed than currently available in typical peer reviewed journals has been identified as an actionable area for improvement. In the biochemical and cell biology space, this need has been met through the creation of new journals focused on detailed protocols and materials sourcing. However, this format is not well suited for capturing instrument validation, detailed imaging protocols, and extensive statistical analysis.
View Article and Find Full Text PDFDiscov Oncol
September 2022
Background: Patients undergoing chemoradiation and immune checkpoint inhibitor (ICI) therapy for locally advanced non-small cell lung cancer (NSCLC) experience pulmonary toxicity at higher rates than historical reports. Identifying biomarkers beyond conventional clinical factors and radiation dosimetry is especially relevant in the modern cancer immunotherapy era. We investigated the role of novel functional lung radiomics, relative to functional lung dosimetry and clinical characteristics, for pneumonitis risk stratification in locally advanced NSCLC.
View Article and Find Full Text PDFPurpose: We sought to examine the prognostic value of fluorodeoxyglucose-positron emission tomography (PET) imaging during chemoradiation for unresectable non-small cell lung cancer for survival and hypothesized that tumor PET response is correlated with peripheral T-cell function.
Methods And Materials: Forty-five patients with American Joint Committee on Cancer version 7 stage IIB-IIIB non-small cell lung cancer enrolled in a phase II trial and received platinum-doublet chemotherapy concurrent with 6 weeks of radiation (NCT02773238). Fluorodeoxyglucose-PET was performed before treatment start and after 24 Gy of radiation (week 3).
IEEE Trans Radiat Plasma Med Sci
April 2022
Purpose: We characterize the performance of a dualsided position-sensitive sparse sensor (DS-PS3) array detector for positron emission tomography (PET). The DS-PS3 detector is designed as a high performance, cost effective PET detector for organ-specific imaging systems (e.g.
View Article and Find Full Text PDFPurpose Of The Report: We evaluated the reliability of 18F-FDG PET imaging biomarkers to classify early response status across observers, scanners, and reconstruction algorithms in support of biologically adaptive radiation therapy for locally advanced non-small cell lung cancer.
Patients And Methods: Thirty-one patients with unresectable locally advanced non-small cell lung cancer were prospectively enrolled on a phase 2 trial (NCT02773238) and underwent 18F-FDG PET on GE Discovery STE (DSTE) or GE Discovery MI (DMI) PET/CT systems at baseline and during the third week external beam radiation therapy regimens. All PET scans were reconstructed using OSEM; GE-DMI scans were also reconstructed with BSREM-TOF (block sequential regularized expectation maximization reconstruction algorithm incorporating time of flight).
Glypican-3 (GPC3) is a tumor associated antigen expressed by hepatocellular carcinoma (HCC) cells. This preclinical study evaluated the efficacy of a theranostic platform using a GPC3-targeting antibody αGPC3 conjugated to zirconium-89 (Zr) and yttrium-90 (Y) to identify, treat, and assess treatment response in a murine model of HCC. A murine orthotopic xenograft model of HCC was generated.
View Article and Find Full Text PDFWe investigated the sensitivity of regional tumor response prediction to variability in voxel clustering techniques, imaging features, and machine learning algorithms in 25 patients with locally advanced non-small cell lung cancer (LA-NSCLC) enrolled on the FLARE-RT clinical trial. Metabolic tumor volumes (MTV) from pre-chemoradiation (PETpre) and mid-chemoradiation fluorodeoxyglucose-positron emission tomography (FDG PET) images (PETmid) were subdivided into K-means or hierarchical voxel clusters by standardized uptake values (SUV) and 3D-positions. MTV cluster separability was evaluated by CH index, and morphologic changes were captured by Dice similarity and centroid Euclidean distance.
View Article and Find Full Text PDFSmall animal research is an essential tool in studying both pharmaceutical biodistribution and disease progression over time. Furthermore, through the rapid development ofimaging technology over the last few decades, small animal imaging (also referred to as preclinical imaging) has become a mainstay for all fields of biologic research and a center point for most preclinical cancer research. Preclinical imaging modalities include optical, MRI and MRS, microCT, small animal PET, ultrasound, and photoacoustic, each with their individual strengths.
View Article and Find Full Text PDFPurpose: Currently, single-photon emission computed tomography (SPECT)/computed tomography (CT) lung phantoms are commonly constructed using polystyrene beads and interstitial radioactive water. However, this approach often results in a phantom with a density (typically -640 HU) that is considerably higher than that of healthy lung (-750 to -850 HU) or diseased lung (-900 to -950 HU). Furthermore, the polystyrene and water phantoms are often quite heterogeneous in both density and activity concentration, especially when reused.
View Article and Find Full Text PDFPurpose: External-beam radiation is the single most effective therapy for localized lymphoma. However, toxicity limits its use for multifocal disease. We evaluated CD45 as a therapeutic target for an antibody-radionuclide conjugate (ARC) for the treatment of lymphoma based on its ubiquitous expression, infrequent antigen loss or blockade, and the ability to target minimal disease based on panhematopoietic expression.
View Article and Find Full Text PDFObjective: The effect of functional lung avoidance planning on radiation dose-dependent changes in regional lung perfusion is unknown. We characterized dose-perfusion response on longitudinal perfusion single photon emission computed tomography (SPECT)/CT in two cohorts of lung cancer patients treated with and without functional lung avoidance techniques.
Methods: The study included 28 primary lung cancer patients: 20 from interventional (NCT02773238) (FLARE-RT) and eight from observational (NCT01982123) (LUNG-RT) clinical trials.
Purpose: Prediction of spatially variant response to cancer therapies can inform risk-adaptive management within precision oncology. We developed the "Voxel Forecast" multiscale regression framework for predicting spatially variant tumor response to chemoradiotherapy on fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) imaging.
Experimental Design: Twenty-five patients with locally advanced non-small cell lung cancer, enrolled on the FLARE-RT phase II trial (NCT02773238), underwent FDG PET/CT imaging prior to (PETpre) and during week 3 (PETmid) of concurrent chemoradiotherapy.
IEEE Biomed Circuits Syst Conf
October 2017
A current-mode interface chip for Silicon Photomultiplier (SiPM) array based positron emission tomography (PET) imaging front-ends is described. The circuit uses a high-speed current amplifier with a low input impedance, to minimize signal loss at the SiPM amplifier interface. To reduce the impact of dark noise, a novel high-speed threshold detection/comparator circuit is used to remove unwanted noise events.
View Article and Find Full Text PDFRecognizing the different mechanisms and imaging appearance of extraskeletal Tc-99m methylene diphosphonate uptake enhances the diagnostic value of bone scan interpretation. In this article, we present a pictorial review of the different mechanisms of extraskeletal Tc-99m methylene diphosphonate uptake on bone scintigraphy including neoplastic, inflammatory, ischemic, traumatic, excretory, and iatrogenic. We also illustrate through case examples the added value of correlation with cross-sectional and single photon emission computed tomography and computed tomography imaging in localizing and characterizing challenging cases of extraskeletal uptake.
View Article and Find Full Text PDFPurpose: A semiquantitative assessment of hepatic reticuloendothelial system function using colloidal particles scintigraphy has been proposed previously as a surrogate for liver function evaluation. In this article, we present an updated method for the overall assessment of technetium-99m (Tc)-sulfur colloid (SC) biodistribution that combines information from planar and attenuation-corrected Tc-SC single-photon emission computed tomography (SPECT) images. The imaging protocol described here was developed as an easy-to-implement method to assess overall and regional liver function changes associated with chronic liver disease.
View Article and Find Full Text PDFPurpose: Nonsmall cell lung cancer (NSCLC) patient radiation therapy (RT) is planned without consideration of spatial heterogeneity in lung function or tumor response. We assessed the dosimetric and clinical feasibility of functional lung avoidance and response-adaptive escalation (FLARE) RT to reduce dose to [ Tc]MAA-SPECT/CT perfused lung while redistributing an escalated boost dose within [ F]FDG-PET/CT-defined biological target volumes (BTV).
Methods: Eight stage IIB-IIIB NSCLC patients underwent FDG-PET/CT and MAA-SPECT/CT treatment planning scans.
Purpose: To design and apply a framework for predicting symptomatic radiation pneumonitis in patients undergoing thoracic radiation, using both pretreatment anatomic and perfused lung dose-volume parameters.
Materials And Methods: Radiation treatment planning CT scans were coregistered with pretreatment [Tc]MAA perfusion SPECT/CT scans of 20 patients who underwent definitive thoracic radiation. Clinical radiation pneumonitis was defined as grade ≥ 2 (CTCAE v4 grading system).
Background: The purpose of this study was twofold: to evaluate the quantitative stability of a SPECT/CT gamma camera over time and to determine if daily flood acquisitions can reliably serve as calibration factors for quantitative SPECT. Using a cylindrical water phantom filled with measured amounts of (99m)Tc, factors were calculated to convert counts/cc to activity/cps. Measurements were made over an 18-month period.
View Article and Find Full Text PDFBackground: Assessment of liver function is critical in hepatocellular carcinoma (HCC) patient management. We evaluated parameters of [(99m)Tc] sulfur colloid (SC) SPECT/CT liver uptake for association with clinical measures of liver function and outcome in HCC patients.
Methods: Thirty patients with HCC and variable Child-Turcotte-Pugh scores (CTP A5-C10) underwent [(99m)Tc]SC SPECT/CT scans for radiotherapy planning.
Digital silicon photomultiplers (dSiPMs) have potential in the advancement of PET detectors. Their advantages include decreased dark counts through selective microcell activation, fast timing, and flexibility configuring event triggering and collection. Further improvements in PET image resolution are possible when photon depth of interaction (DOI) is available, as this reduces parallax error caused by mispositioning events at the peripheral field of view.
View Article and Find Full Text PDFBackground: A feasibility study was done to assess the capability of digital silicon photomultipliers to measure the Cherenkov luminescence emitted by a β source. Cherenkov luminescence imaging (CLI) is possible with a charge coupled device (CCD) based technology, but a stand-alone technique for quantitative activity measurements based on Cherenkov luminescence has not yet been developed. Silicon photomultipliers (SiPMs) are photon counting devices with a fast impulse response and can potentially be used to quantify β-emitting radiotracer distributions by CLI.
View Article and Find Full Text PDFThis study sought to discover which atherosclerotic plaque components co-localize with enhanced [(18)F]-fluorodeoxyglucose (FDG) uptake in carotid positron emission tomography (PET) images. Although in vivo PET currently lacks the resolution, high-resolution ex vivo FDG-microPET with histology validation of excised carotid plaque might accomplish this goal. Thirteen patients were injected with FDG before carotid endarterectomy.
View Article and Find Full Text PDF