Purpose: The purpose of this study was to document the improved accuracy of the pencil beam redefinition algorithm (PBRA) compared to the pencil beam algorithm (PBA) for bolus electron conformal therapy using cylindrical patient phantoms based on patient computed tomography (CT) scans of retromolar trigone and nose cancer.
Methods: PBRA and PBA electron dose calculations were compared with measured dose in retromolar trigone and nose phantoms both with and without bolus. For the bolus treatment plans, a radiation oncologist outlined a planning target volume (PTV) on the central axis slice of the CT scan for each phantom.
Background And Purpose: To investigate combining unmodulated electron beams with intensity-modulated radiation therapy to improve dose distributions for superficial head and neck cancers, and to compare mixed beam plans with helical tomotherapy.
Materials And Methods: Mixed beam and helical tomotherapy dose plans were developed for two patients with parotid gland tumors and two patients with nasal cavity tumors. Mixed beam plans consisted of various weightings of a enface electron beam and IMRT, which was optimized after calculation of the electron dose to compensate for heterogeneity in the electron dose distribution within the target volume.
Helical tomotherapy plans using a combination of pitch and jaw width settings were developed for 3 patients previously treated for head and neck cancer. Three jaw widths (5, 2.5, and 1 cm) and 4 pitches (0.
View Article and Find Full Text PDFThis study assessed the potential of using megavoltage CT (MVCT) images taken with high density skin collimation in place for electron beam treatment planning. MVCT images were taken using the TomoTherapy Hi-Art system (TomoTherapy Inc., Madison, WI), and the CT numbers were converted to density by calibrating the Hi-Art system using an electron density phantom.
View Article and Find Full Text PDFPurpose: To investigate helical tomotherapy (HT) intensity-modulated radiotherapy (IMRT) as a postoperative treatment for parotid gland tumors.
Methods And Materials: Helical tomotherapy plans were developed for 4 patients previously treated with segmental multileaf collimator (SMLC) IMRT. A primary planning target volume (PTV64) and two secondary PTVs (PTV60, PTV54) were defined.
The purpose of the present study is to demonstrate that the use of an electron applicator with energy-dependent source-to-collimator distances (SCDs) will significantly improve the dose homogeneity for abutted electron fields in segmented-field electron conformal therapy (ECT). Multiple Coulomb scattering theory was used to calculate and study the P(80-20) penumbra width of off-axis dose profiles as a function of air gap and depth. Collimating insert locations with air gaps (collimator-to-isocenter distance) of 5.
View Article and Find Full Text PDF