Objective: To report the midterm clinical outcomes from the GORE® EXCLUDER® Conformable AAA Endoprosthesis system (EXCC) pivotal regulatory trial in the United States (U.S.).
View Article and Find Full Text PDFObjective: To report the investigational device exemption study 1-year clinical outcomes of the high neck angulation (HNA) substudy of the GORE EXCLUDER Conformable AAA Endoprosthesis (EXCC) for treatment of infrarenal abdominal aortic aneurysms (AAAs).
Methods: This study is a prospective, multicenter clinical trial conducted in the United States and included core laboratory assessment of imaging and independent event adjudication. Anatomical criteria for enrollment in the HNA substudy included infrarenal aortic neck angulation >60° and ≤90° with aortic neck length ≥10 mm.
We describe a case of an abdominal aortic aneurysm (AAA) and angulated proximal neck treated with a Gore Excluder conformable endoprosthesis and show relevant technical pitfalls in the deployment of the graft main body. An 82-year-old man presented with a 71-mm asymptomatic AAA with an angulated infrarenal proximal neck (75°) and was referred to our unit. The patient was treated with a 26-mm Gore Excluder conformable device, which was deployed slightly above the renal arteries after precatheterization of the lowest renal artery.
View Article and Find Full Text PDFJ Vasc Surg Cases Innov Tech
September 2023
A 72-year-old man receiving anticoagulation therapy for chronic bilateral deep vein thromboses presented with acute right leg swelling. Right-sided imaging showed deep femoral vein thrombosis, chronic partial femoral vein thrombosis, and 4.8-cm distal external iliac vein dilation with possible right iliac vein stenosis.
View Article and Find Full Text PDFJ Vasc Surg Cases Innov Tech
September 2023
Background: Transcarotid artery revascularization (TCAR) with reverse-flow neuroprotection has emerged as an alternative to transfemoral carotid artery stenting and carotid endarterectomy. However, it requires fluoroscopic guidance, exposing the patient and surgeon to radiation. Although fusion-guided endovascular aneurysm repair has been demonstrated to significantly decrease this radiation risk, not much is known about similar outcomes for TCAR.
View Article and Find Full Text PDFA 61-year-old man presented with a 5.8-cm abdominal aortic aneurysm with bilateral pelvic kidneys incidentally discovered by computed tomography angiography. Given the complex anatomy, an open approach was favored over an endovascular approach to address the aneurysm and preserve renal function.
View Article and Find Full Text PDFJ Vasc Surg Cases Innov Tech
December 2022
A lower extremity venous aneurysm is an uncommon vascular disease known to increase a patient's risk of pulmonary embolism. Although most will be popliteal venous aneurysms, crural aneurysms have been rarely documented. We have presented a rare case of a soleal venous aneurysm in a patient with a history of pulmonary embolism.
View Article and Find Full Text PDFBackground: Endovascular intervention has become the first-line treatment of patients with abdominal aortic aneurysms (AAAs) or aortoiliac occlusive disease (AIOD). However, open abdominal aortic repair remains a valuable treatment option for patients who are younger, those with unfavorable anatomy, and patients for whom endovascular intervention has failed. The cohort of patients undergoing open repair has become highly selected; nevertheless, updated outcomes or patient selection recommendations have been unavailable.
View Article and Find Full Text PDFJ Vasc Surg Cases Innov Tech
September 2022
A 61-year-old woman with May-Thurner anatomy status post recent hysterectomy was found to have two iliac vein aneurysms on postoperative magnetic resonance imaging. Transfemoral venography showed the venous aneurysms received retrograde flow from the left internal iliac vein and the left common iliac vein (CIV) was compressed by the right common iliac artery. Both aneurysms were coil embolized and a left CIV stent was placed.
View Article and Find Full Text PDFBackground: The use of warfarin for anticoagulation in thromboembolic disease has been the mainstay of treatment. Direct oral anticoagulants (DOACs) have demonstrated equivalent anticoagulant effects, without increased bleeding risks or need for frequent monitoring. However, the role of DOACs remains unclear in the setting of replacing warfarin for high-risk peripheral artery disease (PAD) interventions.
View Article and Find Full Text PDFBackground: Endovascular aneurysm repair (EVAR) has become the preferred treatment of abdominal aortic aneurysms (AAAs). Recent studies have demonstrated that cases of EVAR failure repair and subsequent open conversion have increased. The aim of the present study was to evaluate the national trend of annual cases and assess the 30-day outcomes of conversion to open repair after failed EVAR compared with primary open repair.
View Article and Find Full Text PDFObjective: To report the 1-year clinical outcomes from the GORE EXCLUDER Conformable AAA Endoprosthesis system in the US regulatory trial.
Methods: The study is a prospective, multicenter, investigational device exemption clinical trial at 31 US sites with core laboratory assessment of imaging and independent event adjudication. The primary safety (incidence of major adverse events at 30 days) and effectiveness end points (successful aneurysm treatment at 1 year) were assessed in a cohort of patients with abdominal aortic aneurysms (AAAs).
J Vasc Surg Cases Innov Tech
June 2022
An 87-year-old woman with grade IIIb follicular lymphoma treated with rituximab had presented with nausea, emesis, and chest pain of 1 day duration. She was found to have a contained abdominal aortic rupture secondary to follicular lymphoma invasion. She safely and successfully underwent emergent endovascular aortic repair.
View Article and Find Full Text PDFThere is no consensus on the best treatment modality for acute distal embolization complications during endovascular interventions for peripheral arterial diseases. We report on 3 patients who underwent mechanical embolectomy using a distal embolic protection device (EPD). All patients showed angiographic evidence of distal embolism, which occurred during lower extremity limb salvage endovascular procedures.
View Article and Find Full Text PDFIntroduction: Central venous obstruction (CVO) often arises among hemodialysis patients with upper extremity access due to a varying number of risk factors. While the true incidence of CVO in hemodialysis patients is unknown, it been reported in the range of 20%-40% in dialysis patients undergoing venograms. In the non-hemodialysis population, chronic central vein obstruction has a compensatory mechanism comprised of numerous collaterals along the chest wall, neck, and mediastinum.
View Article and Find Full Text PDFSurgical treatment of acute DeBakey type I aortic dissection does not address the entire aorta, which can leave anatomically complex residual aortic dissection in the aortic arch and descending aorta. Open repair has been the standard treatment for this pathology. When the lesions are located in the aortic arch, re-do total arch replacement needs to be performed.
View Article and Find Full Text PDFJ Vasc Surg Cases Innov Tech
December 2020
Coronavirus disease 2019 (COVID-19) is an infectious disease typically manifested as a respiratory infection with a range of symptoms from a mild viral illness to a severe acute respiratory syndrome with multiorgan failure and death. We report a case of a young man presenting with compartment syndrome secondary to COVID-19 viral myositis, with a protracted hospital course further complicated by extensive venous and arterial thrombosis. As the coronavirus pandemic evolves, our understanding of the virus continues to improve; however, a host of unanswered questions remain about atypical presentation and management and treatment options.
View Article and Find Full Text PDFThe impact of the coronavirus disease 2019 (COVID-19) pandemic in New York City (NYC) is dramatic. COVID-19 cases surged, hospitals expanded to meet capacity, and NYC remains the global epicenter of this pandemic. During this unprecedented time, a young woman with known Marfan syndrome presented with an acute complicated type B aortic dissection to our Aortic Center.
View Article and Find Full Text PDFWe report a patient who presented with acute abdominal pain during the COVID-19 pandemic. His work-up revealed rupture of a 5.8 cm abdominal aortic aneurysm.
View Article and Find Full Text PDFObjective: The objective of this study was to evaluate the efficacy of treating type II endoleaks (T2Ls) after aortic endovascular repair with image guidance translumbar puncture using intraoperative cone beam computed tomography with preprocedure computed tomography angiography fusion in hybrid operating rooms.
Methods: Twenty-six consecutive T2L patients in three different institutions were treated between March 2015 and September 2017 by direct translumbar puncture of the abdominal aortic aneurysm (AAA) sac after previous endovascular aortic repair. All patients were treated at a single setting in a cardiovascular hybrid operating room with a workstation featuring needle trajectory planning and guidance software.
Purpose: Percutaneous endovenous iliac stenting has emerged as a new modality in the treatment of advanced chronic venous insufficiency with outflow obstruction. However, the effect of this intervention on the quality of life remains unclear. We examined the impact of iliac venous stenting for outflow obstruction as compared to conservative medical management on the quality of life in severe chronic venous insufficiency patients.