The PediBooster external cardiac compression device is a minimally invasive, non-blood contacting Biventricular Assist Device (BiVAD) intended for pediatric use. It is being developed as a palliative therapy for acute Postcardiotomy Shock (PCS). The PediBooster extracardiac wrap is pneumatically actuated to circumferentially compress the heart, providing co-pulsation support.
View Article and Find Full Text PDFMinimally invasive techniques have been described recently for liver resections. We have developed a surgical approach to liver resection that combines the benefits of minimally invasive surgery with the safety of open liver resection. We have applied this hybrid approach to selected cases, and we feel that it can be adopted by most hepatobiliary surgeons, even those with minimal or no laparoscopic experience.
View Article and Find Full Text PDFObjective: We present the largest, most comprehensive, single center experience to date of minimally invasive liver resection (MILR).
Summary Background Data: Despite anecdotal reports of MILR, few large single center reports have examined these procedures by comparing them to their open counterparts.
Methods: Three hundred MILR were performed between July 2001 and November 2006 at our center for both benign and malignant conditions.
In this retrospective study, the implant course and outcome of patients with ventricular assist devices (VADs) transferred from outlying "spoke" hospitals and converted nonsurgically to a device designed for ambulation at tertiary care "hub" hospitals are evaluated. Factors affecting the crucial decision to transfer and to convert devices have not previously been characterized. Data from 50 patients at 26 US hub institutions were voluntarily submitted to a VAD data registry at ABIOMED, between December 2003 and December 2005.
View Article and Find Full Text PDFThe AbioCor implantable replacement heart provides continuous hydraulic pressure data that are used for control purposes. The magnitude of the end systolic pressure spikes are compared to a preset threshold and used for controlling motor speeds to maintain a full stroke on every beat. Portions of the diastolic pressures of the left and the right side are averaged and can be used for left-right balance control.
View Article and Find Full Text PDFIn patients hospitalized with decompensated life-threatening heart failure, the impact of newer pharmacologic therapies and mechanical circulatory support has not yet been realized, except for those who are bridged to cardiac transplantation. For long-term support of transplant-ineligible patients who have severe biventricular failure that is refractory to optimized pharmacologic therapy, replacement of the natural heart with a totally implantable mechanical replacement heart, capable of producing blood flow of up to 8 to 10 L/min, may become the most well tolerated and effective treatment. This article summarizes the current status of the first generation implantable replacement heart (AbioCor trade mark, ABIOMED.
View Article and Find Full Text PDFBackground And Objectives: Concentrated protein solutions can be used as thermally polymerized solders in laser welding. Solders supplemented with biologically active chemicals may provide in situ drug delivery for localized therapeutics. These studies characterize a serum albumin (SA) solder containing heparin, designed to reduce microvascular thrombosis rates.
View Article and Find Full Text PDFA magnetically suspended centrifugal blood pump intended for application as a long-term implantable ventricular assist device has been built and tested. The rotor is freely suspended in the blood by magnetic and hydrostatic restoring forces. This design obviates the need for bearings and shaft seals, and eliminates the problems of reliability and thrombogenicity associated with them.
View Article and Find Full Text PDF