Background: Preprocedural computed tomography planning improves procedural safety and efficacy of transcatheter aortic valve implantation (TAVI). However, contemporary imaging modalities do not account for device-host interactions.
Aims: This study evaluates the value of preprocedural computer simulation with FEops HEARTguide on overall device success in patients with challenging anatomies undergoing TAVI with a contemporary self-expanding supra-annular transcatheter heart valve.
Cardiovasc Revasc Med
December 2023
Background/purpose: This prospective, open-label, single-arm study evaluated transcatheter aortic valve replacement (TAVR) in patients with severe aortic stenosis with ACURATE Prime XL, an iteration of the ACURATE neo2 device designed with improved radial force and adaptations for compatibility with a larger annulus diameter (≥ 26.5 mm and ≤ 29 mm based on pre-procedure diagnostic imaging).
Methods: The composite primary device success endpoint was based on Valve Academic Research Consortium (VARC)-2 criteria.
Background: Most approaches to the creation of an interatrial shunt require placement of a permanent implant to maintain patency.
Objectives: The goal of this study was to investigate the safety and efficacy of a no-implant interatrial shunt for patients with heart failure with preserved ejection fraction (HFpEF) and heart failure with mildly reduced ejection fraction (HFmrEF).
Methods: This was a multicenter, uncontrolled study of patients with HFpEF/HFmrEF and NYHA functional class ≥II, ejection fraction >40%, and pulmonary capillary wedge pressure (PCWP) during supine exercise ≥25 mm Hg with PCWP-to-right atrial gradient ≥5 mm Hg.
Background: Transcatheter aortic valve replacement (TAVR) is increasingly being used to treat younger, lower-risk patients with bicuspid aortic valve (BAV). Patient-specific computer simulation may identify patients at risk for developing paravalvular regurgitation (PVR) and major conduction disturbance. Only limited prospective experience of this technology exist.
View Article and Find Full Text PDFSubclinical leaflet thrombosis (LT) may occur following surgical and transcatheter aortic valve replacement. Computed tomography (CT) has become an established imaging modality to diagnose subclinical LT following bioprosthetic aortic valve replacement. Even so, there is a limited (but growing) experience in utilizing CT imaging for this indication.
View Article and Find Full Text PDFBackground: Transcatheter aortic-valve replacement (TAVR) for the treatment of aortic stenosis can lead to embolization of debris. Capture of debris by devices that provide cerebral embolic protection (CEP) may reduce the risk of stroke.
Methods: We randomly assigned patients with aortic stenosis in a 1:1 ratio to undergo transfemoral TAVR with CEP (CEP group) or without CEP (control group).
Background: Quantitative flow ratio (QFR) may be used to assess the functional significance of coronary lesions. Only limited validation exists for this technology in the setting of severe aortic stenosis.
Methods: A prospective study was performed on patients who were being considered for transcatheter aortic valve implantation.
Background: Patient-specific computer simulation may predict the development of conduction disturbance following transcatheter aortic valve replacement (TAVR). Validation of the computer simulations with current-generation devices has not been undertaken.
Methods: A retrospective study was performed on patients who had undergone TAVR with a current-generation self-expanding transcatheter heart valve (THV).
Background: Countries who suffered large COVID-19 outbreaks reported a decrease in acute coronary syndrome (ACS) presentations and percutaneous coronary intervention (PCI). The impact of the pandemic in countries like Australia, with relatively small outbreaks yet significant social restrictions, is relatively unknown. There is also limited and conflicting data regarding the impact on clinical outcomes, symptom-to-door time (STDT) and door-to-balloon time (DTBT).
View Article and Find Full Text PDFBackground: Instantaneous wave-free ratio (iFR) can reliably assess the physiological significance of coronary artery disease (CAD). Previous studies have demonstrated its interchangeability with other non-hyperaemic pressure ratios (NHPR), but there is no data exploring whether this association is maintained in patients with severe aortic stenosis (AS).
Methods: Forty-two patients (67 lesions) with severe AS were recruited and underwent invasive pressure-wire assessment.
Objective: To determine the association between prosthesis geometry with leaflet thrombosis (LT).
Background: Leaflet thrombosis following transcatheter aortic valve replacement (TAVR) is a recognised entity. The association between prosthesis geometry with LT is unclear but maybe a potential modifiable factor in its prevention.
Background: Patient-specific computer simulation may predict the development of paravalvular regurgitation (PVR) after transcatheter aortic valve replacement (TAVR). We hypothesised that patient-specific computer simulation might identify patients at risk for long-term adverse outcomes after TAVR.
Methods: A multi-centre retrospective study was performed on patients with symptomatic severe aortic stenosis who had undergone TAVR with a self-expanding transcatheter heart valve (THV).
Background: Hypo-attenuated leaflet thickening (HALT) may occur following transcatheter aortic valve replacement (TAVR), however, it remains unclear if HALT is a predictor of haemodynamic valve deterioration (HVD).
Aim: To determine the impact of HALT on the occurrence of HVD.
Methods: We prospectively evaluated 186 patients for the presence of HALT at a median of 6 weeks following TAVR (Interquartile-range [IQR] 4-12 weeks).
Transcatheter aortic valve implantation (TAVI) is increasingly being used to treat younger, lower-risk patients, many of whom have bicuspid aortic valve (BAV). As TAVI begins to enter these younger patient cohorts, it is critical that clinical outcomes from TAVI in BAV are matched to those achieved by surgery. Therefore, the identification of patients who, on an anatomical basis, may not be suitable for TAVI, would be desirable.
View Article and Find Full Text PDFBackground: Patients with severe aortic stenosis (AS) exhibit systemic endothelial dysfunction, which can be associated with myocardial ischaemia in absence of obstructive coronary disease. Transcatheter aortic valve replacement (TAVR) is used to treat severe AS in patients with high or prohibitive surgical risk. However, it remains unknown whether endothelial function recovers post-TAVR.
View Article and Find Full Text PDFBackground: The clinical predictors and sequelae of leaflet thrombosis (LT) following transcatheter aortic valve replacement (TAVR) is still unclear. Therefore, our aim was to determine the clinical predictors and sequelae at mid-term follow-up of computed tomography (CT)-defined LT following TAVR.
Methods And Results: We performed a prospective evaluation with a 320-multislice CT following TAVR for the presence of LT, defined as hypo-attenuated leaflet thickening (HALT).
Background/purpose: Coronary artery disease (CAD) is common in patients undergoing transcatheter aortic valve replacement (TAVR), although its prognostic significance is questionable. Significant CAD stratified using SYNTAX score (SS) has been associated with greater mortality, yet it is unknown whether the functional impact of CAD also impacts outcomes in this cohort. DILEMMA score (DS) is a validated angiographic functional scoring tool that correlates with fractional flow reserve and instantaneous wave-free ratio.
View Article and Find Full Text PDFSevere aortic stenosis induces abnormalities in central aortic pressure, with consequent impaired organ and tissue perfusion. Relief of aortic stenosis by transcatheter aortic valve replacement (TAVR) is associated with both a short- and long-term hypertensive response. Counterintuitively, patients who are long-term normotensive post-TAVR have a worsened prognosis compared with patients with hypertension, yet the underlying mechanisms are not understood.
View Article and Find Full Text PDFBackground: Bioresorbable scaffolds (BRS) are a novel technology in coronary intervention. However, recent trials demonstrate higher rates of device failure compared to contemporary drug-eluting stents. This study sought to utilise a clinical quality registry to assess the medium-term safety of the Abbott Absorb BRS (Abbott Vascular, Santa Clara, CA, USA), in an Australian context.
View Article and Find Full Text PDFObjectives: This study proposes a physiologic assessment of left ventricular outflow tract obstruction (LVOTO) that accommodates changes in systolic flow and accounts for the dynamic neo-left ventricular outflow tract (LVOT).
Background: Patients considered for transcatheter mitral valve replacement trials often screen-fail because of the perceived risk of LVOTO. In the Intrepid Global Pilot Study, assumed risk of LVOTO was based on computed tomography estimates of the neo-LVOT area computed at end-systole.