Hypertrophic scarring is a common complication in severely burned patients who undergo autologous skin grafting. Meshed skin grafts tend to contract during wound healing, increasing the risk of pathological scarring. Although various technologies have been used to study cellular contraction, current methods for measuring contractile forces at the tissue level are limited and do not replicate the complexity of native tissues.
View Article and Find Full Text PDFInnovative therapies combining gene-corrected stem cells and the production of bioengineered tissues to treat epidermolysis bullosa are emerging. However, quantitative tests to measure the adhesion forces between two highly viscoelastic substrates such as those found in bilayered bioengineered skin are needed and are still lacking. The objective of this study was to develop a mechanical test to measure the dermal-epidermal adhesion strength of our bilayered tissue-engineered skin substitute (TES) produced with the self-assembly method.
View Article and Find Full Text PDFThere is a clinical need for tissue-engineered small-diameter (<6 mm) vascular grafts since clinical applications are halted by the limited suitability of autologous or synthetic grafts. This study uses the self-assembly approach to produce a fibroblast-derived decellularized vascular scaffold (FDVS) that can be available off-the-shelf. Briefly, extracellular matrix scaffolds were produced using human dermal fibroblasts sheets rolled around a mandrel, maintained in culture to allow for the formation of cohesive and three-dimensional tubular constructs, and decellularized by immersion in deionized water.
View Article and Find Full Text PDFAs time to final coverage is the essence for better survival outcome in severely burned patients, we have continuously strived to reduce the duration for the preparation of our bilayered self-assembled skin substitutes (SASS). These SASS produced in vitro by the self-assembly approach have a structure and functionality very similar to native skin. Recently, we have shown that a decellularized dermal matrix preproduced by the self-assembly approach could be used as a template to further obtain self-assembled skin substitute using a decellularized dermal template (SASS-DM) in vitro.
View Article and Find Full Text PDFThere is a clinical need for skin substitutes to replace full-thickness skin loss. Our group has developed a bilayered skin substitute produced from the patient's own fibroblasts and keratinocytes referred to as Self-Assembled Skin Substitute (SASS). After cell isolation and expansion, the current time required to produce SASS is 45 days.
View Article and Find Full Text PDFIn the clinical and pharmacological fields, there is a need for the production of tissue-engineered small-diameter blood vessels. We have demonstrated previously that the extracellular matrix (ECM) produced by fibroblasts can be used as a scaffold to support three-dimensional (3D) growth of another cell type. Thus, a resistant tissue-engineered vascular media can be produced when such scaffolds are used to culture smooth muscle cells (SMCs).
View Article and Find Full Text PDFOur bilayered self-assembled skin substitutes (SASS) are skin substitutes showing a structure and functionality very similar to native human skin. These constructs are used, in life-threatening burn wounds, as permanent autologous grafts for the treatment of such affected patients even though their production is exacting. We thus intended to shorten their current production time to improve their clinical applicability.
View Article and Find Full Text PDFConventional approaches for toxicity evaluation of drugs and chemicals, such as animal tests, can be impractical due to the large experimental scale and the immunological differences between species. Organ-on-a-chip models have recently been recognized as a prominent alternative to conventional toxicity tests aiming to simulate the human in vivo physiology. This review focuses on the organ-on-a-chip applications for high-throughput screening of candidate drugs against toxicity, with a particular emphasis on bone-marrow-on-a-chip.
View Article and Find Full Text PDFThere is an ongoing clinical need for tissue-engineered small-diameter (<6mm) vascular grafts since clinical applications are restricted by the limited availability of autologous living grafts or the lack of suitability of synthetic grafts. The present study uses our self-assembly approach to produce a fibroblast-derived decellularized vascular scaffold that can then be available off-the-shelf. Briefly, scaffolds were produced using human dermal fibroblasts sheets rolled around a mandrel, maintained in culture to allow for the formation of cohesive and three-dimensional tubular constructs, and then decellularized by immersion in deionized water.
View Article and Find Full Text PDFThe aortic heart valve is constantly subjected to pulsatile flow and pressure gradients which, associated with cardiovascular risk factors and abnormal hemodynamics (i.e. altered wall shear stress), can cause stenosis and calcification of the leaflets and result in valve malfunction and impaired circulation.
View Article and Find Full Text PDFDelivery of therapeutic agents via the pulmonary route has gained significant attention over the past few decades because this route of administration offers multiple advantages over traditional routes that include localized action, non-invasive nature and favorable lung-to-plasma ratio. However, assessment of post administration behavior of inhaled pharmaceuticals-such as deposition of particles over the respiratory airways, interaction with the respiratory fluid and movement across the air-blood barrier-is challenging because the lung is a very complex organs that is composed of airways with thousands of bifurcations with variable diameters. Thus, much effort has been put forward to develop models that mimic human lungs and allow evaluation of various pharmaceutical and physiological factors that influence the deposition and absorption profiles of inhaled formulations.
View Article and Find Full Text PDFJ Tissue Eng Regen Med
November 2015
Despite a wide panel of tissue-engineering models available for vesical reconstruction, the lack of a differentiated urothelium remains their main common limitation. For the first time to our knowledge, an entirely human vesical equivalent, free of exogenous matrix, has been reconstructed using the self-assembly method. Moreover, we tested the contribution of adipose-derived stromal cells, an easily available source of mesenchymal cells featuring many potential advantages, by reconstructing three types of equivalent, named fibroblast vesical equivalent, adipose-derived stromal cell vesical equivalent and hybrid vesical equivalent--the latter containing both adipose-derived stromal cells and fibroblasts.
View Article and Find Full Text PDFMarine mammals experience unique physiological conditions when diving. Myocardial function is sustained despite a 90% reduction of the blood flow in the coronaries. Therefore, their heart valves and pericardium could serve as a unique source of tissue for the manufacture of prosthetic heart valves.
View Article and Find Full Text PDFA failing mitral valve prosthesis made from bovine pericardium was explanted from a 50-year-old patient. Preoperative transthoracic-echocardiography had confirmed severe mitral regurgitation due to structural failure of this HP Bio bovine pericardium heart valve prosthesis. The explanted device was examined macroscopically, by scanning electron microscopy (SEM), by light microscopy, and by transmission electron microscopy (TEM).
View Article and Find Full Text PDFOnly a few engineered tissues-skin, cartilage, bladder-have achieved clinical success, and biomaterials designed to replace more complex organs are still far from commercial availability. This gap exists in part because biomaterials lack a vascular network to transfer the oxygen and nutrients necessary for survival and integration after transplantation. Thus, generation of a functional vasculature is essential to the clinical success of engineered tissue constructs and remains a key challenge for regenerative medicine.
View Article and Find Full Text PDFRationale: Prosthetic heart valves designed to be implanted percutaneously must be loaded within delivery catheters whose diameter can be as low as 18 F (6 mm). This mandatory crimping of the devices may result in deleterious damages to the tissues used for valve manufacturing. As bovine and porcine pericardial tissue are currently given preference because of their excellent availability and traceability, a preliminary comparative study was undertaken to highlight their potential advantages.
View Article and Find Full Text PDFThe human umbilical cord (UC) has attracted interest as a source of cells for many research applications. UC solid tissues contain four cell types: epithelial, stromal, smooth muscle and endothelial cells. We have developed a unique protocol for the sequential extraction of all four cell types from a single UC, allowing tissue reconstruction using multiple cell types from the same source.
View Article and Find Full Text PDFAm J Physiol Lung Cell Mol Physiol
November 2012
Development of lung models for testing a drug substance or delivery system has been an intensive area of research. However, a model that mimics physiological and anatomical features of human lungs is yet to be established. Although in vitro lung models, developed and fine-tuned over the past few decades, were instrumental for the development of many commercially available drugs, they are suboptimal in reproducing the physiological microenvironment and complex anatomy of human lungs.
View Article and Find Full Text PDFBackground: After human epidermis wounding, transepithelial potential (TEP) present in nonlesional epidermis decreases and induces an endogenous direct current epithelial electric field (EEF) that could be implicated in the wound re-epithelialization. Some studies suggest that exogenous electric stimulation of wounds can stimulate healing, although the mechanisms remain to be determined.
The Problem: Little is known concerning the exact action of the EEF during healing.
The success of tissue engineering will rely on the ability to generate complex, cell seeded three-dimensional (3D) structures. Therefore, methods that can be used to precisely engineer the architecture and topography of scaffolding materials will represent a critical aspect of functional tissue engineering. Previous approaches for 3D scaffold fabrication based on top-down and process driven methods are often not adequate to produce complex structures due to the lack of control on scaffold architecture, porosity, and cellular interactions.
View Article and Find Full Text PDFThe structural stability of skin substitutes is critical to avoid aesthetic and functional problems after grafting, such as contractures and hypertrophic scars. The present study was designed to assess the production steps having an influence on the contractile behaviour of the tissue-engineered skin made by the self-assembly approach, where keratinocytes are cultured on tissue-engineered dermis comprised of fibroblasts and the endogenous extracellular matrix they organized. Thus, different aspects were investigated, such as the assembly method of the engineered dermis (various sizes and anchoring designs) and the impact of epithelial cell differentiation (culture submerged in the medium or at the air-liquid interface).
View Article and Find Full Text PDF