Publications by authors named "Robert D Speller"

A system using energy-dispersive X-ray diffraction (EDXRD) has been developed and tested using multivariate calibration for the quantitative analysis of tablet-form mixtures of common pharmaceutical ingredients. A principal advantage of EDXRD over the more traditional and common angular dispersive X-ray diffraction technique (ADXRD) is the potential of EDXRD to analyse tablets within their packaging, due to the higher energy X-rays used. In the experiment, a series of caffeine, paracetamol and microcrystalline cellulose mixtures were prepared and pressed into tablets.

View Article and Find Full Text PDF

This pilot study examines the correlation of X-ray diffraction (XRD) measurements with the histopathological analysis of breast tissue. Eight breast cancer samples were investigated. Each sample contained a mixture of normal and cancerous tissues.

View Article and Find Full Text PDF

We report on the design and realization of an x-ray imaging system for quantitative phase-contrast microscopy at high x-ray energy with laboratory-scale instrumentation. Phase and amplitude were separated quantitatively at x-ray energies up to 80 keV with micrometric spatial resolution. The accuracy of the results was tested against numerical simulations, and the spatial resolution was experimentally quantified by measuring a Siemens star phase object.

View Article and Find Full Text PDF

In this note we present the first proof-of-concept results on the potential effectiveness of the edge-illumination x-ray phase contrast method (in its 'coded-aperture' based lab implementation) combined with tomosynthesis. We believe that, albeit admittedly preliminary (e.g.

View Article and Find Full Text PDF

We present a quantitative, non-interferometric, X-ray differential phase contrast imaging technique based on the edge illumination principle. We derive a novel phase retrieval algorithm which requires only two images to be acquired and verify the technique experimentally using synchrotron radiation. The technique is useful for planar imaging but is expected to be important for quantitative phase tomography also.

View Article and Find Full Text PDF

X-ray phase contrast imaging has overcome the limitations of X-ray absorption imaging in many fields. Particular effort has been directed towards developing phase retrieval methods: These reveal quantitative information about a sample, which is a requirement for performing X-ray phase tomography, allows material identification and better distinction between tissue types, etc. Phase retrieval seems impossible with conventional X-ray sources due to their low spatial coherence.

View Article and Find Full Text PDF

Purpose: The x-ray performance evaluation of digital x-ray detectors is based on the calculation of the modulation transfer function (MTF), the noise power spectrum (NPS), and the resultant detective quantum efficiency (DQE). The flat images used for the extraction of the NPS should not contain any fixed pattern noise (FPN) to avoid contamination from nonstochastic processes. The "gold standard" method used for the reduction of the FPN (i.

View Article and Find Full Text PDF

Purpose: This paper proposes the further development of a resolution modification routine which is used to simulate the presampling modulation transfer function (pMTF) of digital x-ray detectors.

Methods: It suggests a method to reconstruct anisotropic two dimensional (2D) pMTF matrices from the experimentally measured horizontal and vertical 1D pMTFs. In this study, the horizontal dimension of the detector is 17.

View Article and Find Full Text PDF

X-ray baggage scanners play a basic role in the protection of airports, customs, and other strategically important buildings and infrastructures. The current technology of baggage scanners is based on x-ray attenuation, meaning that the detection of threat objects relies on how various objects differently attenuate the x-ray beams going through them. This capability is enhanced by the use of dual-energy x-ray scanners, which make the determination of the x-ray attenuation characteristics of a material more precise by taking images with different x-ray spectra, and combining the information appropriately.

View Article and Find Full Text PDF

We report on what are believed to be the first full-scale images obtained with the coded aperture concept, which uses conventional x-ray sources without the need to collimate/aperture their output. We discuss the differences in the underpinning physical principles with respect to other methods, and explain why these might lead to a more efficient use of the source. In particular, we discuss how the evaluation of the first imaging system provided promising indications on the method's potential to detect details invisible to conventional absorption methods, use an increased average x-ray energy, and reduce exposure times-all important aspects with regards to real-world implementations.

View Article and Find Full Text PDF

There is currently much interest in developing X-ray Phase Contrast Imaging (XPCI) systems which employ laboratory sources in order to deploy the technique in real world applications. The challenge faced by nearly all XPCI techniques is that of efficiently utilising the x-ray flux emitted by an x-ray tube which is polychromatic and possesses only partial spatial coherence. Techniques have, however, been developed which overcome these limitations.

View Article and Find Full Text PDF

X-ray phase contrast imaging is a very promising technique that may lead to significant advancements in a variety of fields, perhaps most notably, medical imaging. The radiation physics group at University College London is currently developing an x-ray phase contrast imaging technique that works with laboratory x-ray sources. This system essentially measures the degree to which photons are refracted by regions of an imaged object.

View Article and Find Full Text PDF

It is hoped that x-ray phase contrast imaging (XPCi) will provide a generational improvement in the effectiveness of mammography. XPCi is sensitive to the refraction which x-rays undergo as a result of the variation in x-ray propagation speeds within an object. XPCi is, however, seldom used in clinical applications owing mainly to a lack of suitable systems.

View Article and Find Full Text PDF

X-ray phase contrast imaging is a very promising technique which may lead to significant advancements in medical imaging. One of the impediments to the clinical implementation of the technique is the general requirement to have an x-ray source of high coherence. The radiation physics group at UCL is currently developing an x-ray phase contrast imaging technique which works with laboratory x-ray sources.

View Article and Find Full Text PDF

This paper describes the potential application of an active pixel sensor-based x-ray diffraction (APXRD) system in the field of breast cancer diagnosis. The design and initial testing of the system was reported previously (Bohndiek et al 2008b Phys. Med.

View Article and Find Full Text PDF

X-ray diffraction studies give material-specific information about biological tissue. Ideally, a large area, low noise, wide dynamic range digital x-ray detector is required for laboratory-based x-ray diffraction studies. The goal of this work is to introduce a novel imaging technology, the CMOS active pixel sensor (APS) that has the potential to fulfil all these requirements, and demonstrate its feasibility for coherent scatter imaging.

View Article and Find Full Text PDF