Purpose: A complication of transjugular intrahepatic portosystemic shunts (TIPS) placement is refractory portosystemic encephalopathy (PSE) often requiring TIPS reduction. We report the results of a "sheath control technique" utilizing constraining sheaths during deployment of polytetrafluoroethylene (PTFE)-covered balloon-expandable stents, minimizing stent migration, and providing additional procedural control.
Methods: TIPS reduction was performed in 10 consecutive patients for PSE using Atrium iCast covered stents (Atrium Maquet Getinge Group, Germany).
Background: Proximal venous outflow obstruction (PVOO) in the abdomen and pelvis is increasingly recognized as an important contributor to venous disease of the lower extremity. There are currently no guidelines regarding a noninvasive screening tool for PVOO, although magnetic resonance venography (MRV) is commonly used in many practices. The objective of this study was to determine the value and utility of MRV in diagnosis and screening for PVOO.