Therapeutic plasma exchange (TPE) is a cornerstone treatment for antibody-mediated rejection (AMR) post-organ transplantation, aiming to eliminate pathogenic donor-specific HLA antibodies (DSA). However, limitations in HLA antibody interpretation due to the prozone-like effect (PLE) can lead to inaccurate assessment of treatment efficacy. We present a case of a heart transplant recipient with suspected AMR, where an unexpected increase in DSA levels post-TPE prompted investigation into PLE.
View Article and Find Full Text PDFThe clinical impact of HLA DP antibodies is poorly understood, resulting in variable clinical strategies for transplant candidates and recipients with donor-directed HLA-DP antibodies. Complicating matters further, the DPB naming convention is not based on allelic homology and requires sequence alignments to identify potential immunogenic epitopes. Historically, G and P codes, which consolidated alleles that were identical over Exon 2, were used to simplify the reporting of HLA Class II typing as differences outside of Exon 2 have not been considered immunogenic (i.
View Article and Find Full Text PDFBackground: HLA class II antigens, DR, DQ, and DP, comprised an α and β chains, which typically combine, within the same isotype, to form the major histocompatibility complex:peptide complex. Interisotypic pairing is not commonly observed. Although reports of DQβ:DRα heterodimers exist, the pairing was reported to be unstable and, therefore, not studied to any extent.
View Article and Find Full Text PDFAntibodies reactive to human leukocyte antigens (HLA) represent a barrier for patients awaiting transplantation. Based on reactivity patterns in single-antigen bead (SAB) assays, various epitope matching algorithms have been proposed to improve transplant outcomes. However, some antibody reactivities cannot be explained by amino acid motifs, leading to uncertainty about their clinical relevance.
View Article and Find Full Text PDFAlthough rare, infection and vaccination can result in antibodies to human leukocyte antigens (HLA). We analyzed the effect of SARS-CoV-2 infection or vaccination on HLA antibodies in waitlisted renal transplant candidates. Specificities were collected and adjudicated if the calculated panel reactive antibodies (cPRA) changed after exposure.
View Article and Find Full Text PDFBackground: Management of platelet-transfusion refractory (PR) patients due to anti-HLA antibodies includes the provision of HLA-matched (HLAm) platelets (PLT) or PLTs that are negative for HLA antigens corresponding to the recipient antibodies. Obtaining HLAm PLTs is predicated on accurate HLA antigen typing of the recipient and donor. Here, we present the clinical implications of a case involving loss of heterozygosity (LOH) in a patient presented for PR workup.
View Article and Find Full Text PDFShort tandem repeat (STR) analysis to assess chimerism is a critical aspect of routine care particularly in patients facing stem cell transplants but is also relevant in other clinical scenarios. STR analysis provides a means to assess donor and recipient cellular origins in a patient, and, as such, can inform engraftment, rejection, and relapse status in stem cell transplant recipients. In this review of STR testing, the most commonly used method to assess chimerism, its background, procedural details, and clinical utility are discussed.
View Article and Find Full Text PDFThe HLA-B*08:79:02 allele differs from the HLA-B*08:01:01:01 by 4 nucleotides in Exon 3.
View Article and Find Full Text PDFThis study examined the development of new or changes in donor specific antibodies (DSA) mean-fluorescence intensity (MFI) after SARS-CoV-2 vaccination in 100 kidney and 50 heart transplant recipients. The study was performed when the Center for Disease Control and Prevention (CDC) recommended two doses of Pfizer/BioNTech [BNT162b2] and Moderna [mRNA-1273 SARS-CoV-2] vaccine or 1 dose Johnson & Johnson/Janssen [Ad26.COV2·S] vaccines for full vaccination in transplant recipients.
View Article and Find Full Text PDFHistocompatibility testing has continuously evolved since its inception. One such advancement is the implementation of the virtual crossmatch (VXM). Recent changes to allograft allocation schemes have resulted in increased organ sharing over greater distances, resulting in expanded utilization of the VXM to assess donor: recipient compatibility.
View Article and Find Full Text PDFEplet mismatch load, both overall and at the single molecule level, correlates with transplant recipient outcomes. However, precise eplet assessment requires high-resolution HLA typing of both the donor and recipient. Anything less than high-resolution typing requires imputation of HLA types.
View Article and Find Full Text PDFBackground: African American (AA) recipients of deceased-donor (DD) kidney transplants (KT) have shorter allograft survival than recipients of other ethnic groups. Reasons for this disparity encompass complex interactions between donors and recipients characteristics.
Methods: Outcomes from 3872 AA and 19,719 European American (EA) DDs who had one kidney transplanted in an AA recipient and one in an EA recipient were analyzed.
Background: Transplant recipients who develop COVID-19 may be at increased risk for morbidity and mortality. Determining the status of antibodies against SARS-CoV-2 in both candidates and recipients will be important to understand the epidemiology and clinical course of COVID-19 in this population. While there are multiple tests to detect antibodies to SARS-CoV-2, their performance is variable.
View Article and Find Full Text PDFThough solid-phase single antigen bead (SAB) testing has provided major advances to the HLA community and organ allocation, it has not been without limitations. In particular, false-positive reactions lead to interpretative challenges and the potential to preclude a transplant if the corresponding antigens are deemed unacceptable. Two different vendor platforms are commercially available for SAB testing, one more recent than the other.
View Article and Find Full Text PDFIn November 2014, the OPTN/UNOS Board of Directors mandated that HLA-DPB1 typing be performed for all deceased donors. Currently, there are over 1,000 known HLA DPB1 alleles, yet fewer than 30 are represented on commonly used single antigen bead (SAB) solid phase antibody assays. Moreover, the official World Health Organization (WHO) nomenclature for the DPB1 locus does not permit assessment of structural relationships between alleles based on their names.
View Article and Find Full Text PDFIntroduction: Single antigen bead testing (SAB) for HLA-specific antibody enables efficient organ allocation and aids in the diagnosis of antibody mediated rejection. In this retrospective cohort study, a population of kidney transplant recipients possessing HLA Class I antibodies was used to evaluate the best method for resolving complement interference, the so called "prozone" effect. The aim was to compare the use of EDTA versus a Biotin-Streptavidin Complex as methodological approaches for abating the prozone effect using a fixed 1 in 10 dilution as validation.
View Article and Find Full Text PDFThe Organ Procurement and Transplantation Network (OPTN) Kidney Allocation System provides a priority to sensitized candidates based on the calculated panel reactive antibody (CPRA) value. The human leukocyte antigen (HLA) haplotype reference panel used for calculation of the CPRA by the United Network for Organ Sharing (UNOS), the OPTN contractor, has limitations. We derived a novel panel from the National Marrow Donor Program HLA haplotype data set and compared the accuracy of CPRA values generated with this panel (NMDP-CPRA) to those generated from the UNOS panel (UNOS-CPRA), using predicted and actual deceased donor kidney offers for a cohort of 24 282 candidates.
View Article and Find Full Text PDFVirtual crossmatch (VXM) compares a transplant candidate's unacceptable antigens to the HLA typing of the donor before an organ offer is accepted and, in selected cases, supplant a prospective physical crossmatch. However, deceased donor typing can be ambiguous, leading to uncertainty in compatibility prediction. We have developed a prototype web application that utilizes ambiguous HLA molecular typing data to predict which unacceptable antigens are present in the donor HLA genotype as donor-specific antibodies (DSA).
View Article and Find Full Text PDF