Metal nanoparticle-antibody conjugates are often used as optical or electrochemical markers in applications like immunohistochemistry, lateral flow tests, biosensors and immunoassays. In order to serve that role, an antibody needs to be immobilized on the surface of the nanoparticle. This is easily done, as proteins bind to gold and silver nanoparticles spontaneously.
View Article and Find Full Text PDFIn this study, the first steps in the development of a secondary reference measurement procedure (RMP) 'higher metrological order measurement procedure' to support the cardiac troponin I (cTnI) standardization initiative is described. The RMP should be used to assign values to serum-based secondary reference materials (RMs) without analytical artifacts causing bias. A multiplexed bead-based assay and sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) were used to identify the optimum monoclonal antibody pair (clones 560 and 19C7) for the RMP.
View Article and Find Full Text PDFThe laboratory measurement of cardiac troponin (cTn) concentration is a critical tool in the diagnosis of acute myocardial infarction (MI). Current cTnI assays produce different absolute troponin numbers and use different clinical cut-off values; hence cTnI values cannot be interchanged, with consequent confusion for clinicians. A recent Australian study compared patient results for seven cTnI assays and showed that between-method variation was approximately 2- to 5-fold.
View Article and Find Full Text PDFColloidal metal particles, in particular gold, have found many biological applications often as probes in light and electron microscopy, and more recently since the 1980s in membrane-based rapid immunoaffinity tests. The surface plasmon resonance absorbance properties in the visible spectroscopy region of gold colloids make them useful tools in medical devices, as the colloids are directly visible to the naked eye. Despite the relative ease with which gold-protein conjugates can be prepared a major issue is the manufacture of poor-quality and poorly characterised bioconjugates that can result in the under performance of subsequent diagnostic tests.
View Article and Find Full Text PDFStandardization of cardiac troponin I (cTnI) measurement is important because of the central role for diagnosis of myocardial infarction. In blood, cTnI is present as a heterogeneous mixture of different molecular species. The analytical problem caused by this heterogeneity may be circumvented by recognition of a unique, invariant part of the molecule that is common to all components of the mixture.
View Article and Find Full Text PDFBackground: Immunoassays allow the specific detection and quantitation of biological molecules in complex samples at physiologically relevant concentrations. However, there are concerns over the comparability of such techniques when the same assay is performed by different operators or laboratories. An international intercomparison study was performed to assess the uncertainty involved in the estimation of a protein cytokine concentration using a fluorescent ELISA.
View Article and Find Full Text PDF