Objective: Data were extracted from preexisting published studies and evaluated retrospectively to compare lactate and base deficit values at baseline and posthemorrhage with changes in corresponding hemoglobin (Hb) and Hct measurements to assess any association of such changes with severity of hemorrhage over time. To understand the goal, the objective of this study was to demonstrate statistical changes in laboratory values as described above.
Methods: Previous prospectively designed experiments on 120 mixed-breed dogs were conducted.
Purpose: Infusate osmolarity, pH, and cytotoxicity were investigated as risk factors for midline catheter failure.
Methods: An experimental, randomized, controlled, blinded trial was conducted using an ovine model. Two 10-cm, 18-gauge single-lumen midline catheters were inserted into the cephalic veins of sheep.
Objective: To assess IgE response and cytokine gene expressions in pulmonary lymph collected from bovine respiratory syncytial virus (BRSV)-infected calves after ovalbumin inhalation.
Animals: Thirteen 7- to 8-week-old calves.
Procedures: The efferent lymphatic duct of the caudal mediastinal lymph node of each calf was cannulated 3 or 4 days before experiment commencement.
Background: Direct determination of the circulating blood volume (CBV) is clinically desirable, especially when hemodynamic parameters such as blood pressure and heart rate are pharmacologically altered and may not be used with confidence for monitoring of CBV. In a rabbit model, we demonstrated that small volumes of hemoglobin-based oxygen carriers (HBOC) may be used for measuring of CBV with the indicator-dilution technique. This study aimed to verify the technique in a canine hypovolemia model with varying concentrations of infused HBOC.
View Article and Find Full Text PDFObjective: To evaluate the effect of infection with bovine respiratory syncytial virus (BRSV) on clearance of inhaled antigens from the lungs of calves.
Animals: Eleven 6- to 8-week-old Holstein bull calves.
Procedures: Aerosolized (99m)technetium ((99m)Tc)-labeled diethylene triamine pentacetate (DTPA; 3 calves), commonly used to measure integrity of the pulmonary epithelium, and (99m)Tc-labeled ovalbumin (OA; 8 calves), commonly used as a prototype allergen, were used to evaluate pulmonary clearance before, during, and after experimentally induced infection with BRSV or sham inoculation with BRSV.
Objective: To test the hypothesis that low-volume resuscitation with hemoglobin glutamer-200 improves hemodynamic function and tissue oxygenation, whereas arginine vasopressin resuscitation improves blood pressures more than low-volume saline or hemoglobin glutamer infusion but compromises systemic and muscle blood flow and oxygenation.
Design: Randomized laboratory investigation.
Setting: University research facility.
Artif Cells Blood Substit Immobil Biotechnol
May 2007
Allogeneic blood resuscitation is the treatment of choice for hemorrhagic shock. When blood is unavailable, plasma expanders, including crystalloids, colloids, and blood substitutes, may be used. Another treatment modality is vasopressin, a vasoconstrictor administered to redistribute blood flow, increase venous return, and maintain adequate cardiac output.
View Article and Find Full Text PDFObjective: To compare the accuracy of a 3rd (Dolphin Voyager) versus 1st generation pulse oximeter (Nellcor N-180).
Study Design: Prospective laboratory investigation.
Animals: Eight adult dogs.
Systemic function and oxygenation changes during hemorrhagic shock treatment were continuously monitored and correlated with real-time microvascular changes. After splenectomy, each dog (n = 12) was hemorrhaged (MAP = approximately 50 mmHg; approximately 40% blood loss = 32-36 ml/kg) and randomly assigned to 4 resuscitation groups: autologous/shed blood, hemoglobin-based oxygen-carrier/Oxyglobin, crystalloid/saline, and colloid/Hespan. Systemic function and oxygenation changes were continuously monitored and measured using standard operating room protocols.
View Article and Find Full Text PDFArtif Cells Blood Substit Immobil Biotechnol
May 2004
Blood substitute resuscitation as a treatment modality for moderate hypovolemia (approximately 40% blood loss) in a canine model has been evaluated using Oxyglobin (Biopure Hemoglobin Glutamer-200/ Bovine; a hemoglobin-based oxygen-carrier) and Hespan (6% hetastarch; a nonoxygen-carrier) as resuscitants. Autologous (shed) blood served as control. Nine dogs were studied--after splenectomy, each dog was hemorrhaged (32-36 mL/kg; MAP = approximately 50 mmHg) and randomly assigned to the three resuscitation groups.
View Article and Find Full Text PDFThe development of effective, safe vaccines for human and bovine respiratory syncytial virus (RSV) has been problematic. Inactivated RSV vaccines are of variable efficacy; poor efficacy may be related to induction of ineffective cell-mediated immunity (CMI). To characterize CMI in calves vaccinated with formalin inactivated (FI) BRSV, 11 calves were vaccinated twice with FI-BRSV (n=5) or mock vaccine (n=6) at a 2 week interval and challenged 1 month later.
View Article and Find Full Text PDFObjective: To compare effects of 6% hetastarch (Hextend) and hemoglobin-based oxygen carrier hemoglobin glutamer-200 (Hb-200) (bovine; Oxyglobin) on hemodynamics, arterial oxygen content, and systemic oxygen delivery in a canine hemorrhagic shock model.
Design: Randomized laboratory investigation.
Setting: University surgical research facility.
Unlabelled: We measured lead concentrations in three hemoglobin-based oxygen carriers (HBOCs; Oxyglobin, Hemopure, and Hemolink) and compared them with lead concentrations from blood-bank blood. Oxyhemoglobin dissociation was measured with large concentrations of lead in bovine HBOC, with or without bovine blood, and in bovine blood. Samples of each were prepared by combining one with normal saline (control), the second with small lead concentrations (22 micro g/dL), and the third with toxic lead concentrations (70 micro g/dL).
View Article and Find Full Text PDFUnlabelled: In this study, we evaluated the validity of saturation measurements in mixed venous and arterial blood during posthemorrhagic anemia and resuscitation with varying levels of hemoglobin-based oxygen carrier (Hemoglobin glutamer-200 [bovine]; Oxyglobin [Hb-200]). Nineteen anesthetized, splenectomized, mixed-breed dogs were anesthetized (two were excluded from the data because they did not survive the exsanguination, supporting the validity of the model). Their pulmonary arteries were cannulated with the Abbott QVUE Oximetrix 3 catheter.
View Article and Find Full Text PDFPurpose: Accuracy of measurement of low hemoglobin concentrations using the HemoCue, a B-hemoglobin photometer (HemoCue AB, Angelholm, Sweden) may exhibit significant variability. Infusion of hemoglobin-based oxygen carriers (HBOC) results in low concentrations of plasma hemoglobin. Our study assessed B-hemoglobin photometer measurement accuracy of three HBOC: (hemoglobin glutamer-200 (bovine; Oxyglobin, Biopure Corp.
View Article and Find Full Text PDF