Publications by authors named "Rob N Candler"

The magnetoelectric behavior of epitaxial Fe-Ga microstructures on top of a (001)-oriented PMN-PT piezoelectric substrate is imaged with magnetic X-ray microscopy. Additionally, the micron-scale strain distribution in PMN-PT is characterized by X-ray microdiffraction and examined with respect to the results of the Fe-Ga magnetoelectric switching. The magnetic reorientation of Fe-Ga is found to be strongly correlated with size, shape, and crystallographic orientation of the microstructures.

View Article and Find Full Text PDF

Objective: The objective of this study was the preclinical design and construction of a flexible intrasphenoid coil aiming for submillimeter resolution of the human pituitary gland.

Methods: Sphenoid sinus measurements determined coil design constraints for use in > 95% of adult patients. Temperature safety parameters were tested.

View Article and Find Full Text PDF

Magnetic domain wall (DW)-based logic devices offer numerous opportunities for emerging electronics applications allowing superior performance characteristics such as fast motion, high density, and nonvolatility to process information. However, these devices rely on an external magnetic field, which limits their implementation; this is particularly problematic in large-scale applications. Multiferroic systems consisting of a piezoelectric substrate coupled with ferromagnets provide a potential solution that provides the possibility of controlling magnetization through an electric field via magnetoelastic coupling.

View Article and Find Full Text PDF

Programming magnetic fields with microscale control can enable automation at the scale of single cells ≈10 µm. Most magnetic materials provide a consistent magnetic field over time but the direction or field strength at the microscale is not easily modulated. However, magnetostrictive materials, when coupled with ferroelectric material (i.

View Article and Find Full Text PDF

Designing and implementing means of locally trapping magnetic beads and understanding the factors underlying the bead capture force are important steps toward advancing the capture-release process of magnetic particles for biological applications. In particular, capturing magnetically labeled cells using magnetic microstructures with perpendicular magnetic anisotropy (PMA) will enable an approach to cell manipulation for emerging lab-on-a-chip devices. Here, a Co (0.

View Article and Find Full Text PDF

This review examines the state of the art for manufacturing non-planar miniature channels and actuators from PDMS, where non-planar structures are defined here as those beyond simple extrusions of 2D designs, either with rounded or variable cross sections or with an emergence of the channel trajectory out-of-plane. The motivation for 3D PDMS structures and advances in their fabrication are described, focusing on geometries that were previously unachievable through conventional microfabrication. The motivation for non-planar microfluidic channels and actuators is first discussed and the existing literature is grouped into general fabrication themes and described.

View Article and Find Full Text PDF

This work reports on zeolitic imidazolate framework (ZIF)-coupled microscale resonators for highly sensitive and selective gas detection. The combination of microscale resonators and nanoscale materials simultaneously permits the benefit of larger capture area for adsorption from the resonator and enhanced surface adsorption capacity from the nanoscale ZIF structure. Dielectrophoresis (DEP) was demonstrated as a novel method for directly assembling concentrated ZIF nanoparticles on targeted regions of silicon resonant sensors.

View Article and Find Full Text PDF

Although surgical robotic systems provide several advantages over conventional minimally invasive techniques, they are limited by a lack of tactile feedback. Recent research efforts have successfully integrated tactile feedback components onto surgical robotic systems, and have shown significant improvement to surgical control during in vitro experiments. The primary barrier to the adoption of tactile feedback in clinical use is the unavailability of suitable force sensing technologies.

View Article and Find Full Text PDF

We have demonstrated, for the first time, a novel three-dimensional (3D) memory chip architecture of stacked-memory-devices-on-logic (SMOL) achieving up to 95% of cell-area efficiency by directly building up memory devices on top of front-end CMOS devices. In order to realize the SMOL, a unique 3D Flash memory device and vertical integration structure have been successfully developed. The SMOL architecture has great potential to achieve tera-bit level memory density by stacking memory devices vertically and maximizing cell-area efficiency.

View Article and Find Full Text PDF

Experiments were conducted to evaluate a silicon accelerometer as an implantable sound sensor for implantable hearing aids. The main motivation of this study is to find an alternative sound sensor that is implantable inside the body, yet does not suffer from the signal attenuation from the body. The merit of the accelerometer sensor as a sound sensor will be that it will utilize the natural mechanical conduction in the middle ear as a source of the vibration.

View Article and Find Full Text PDF