Publications by authors named "Rickjason C-W Chan"

The continuous and rapid surge of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants with high transmissibility and evading neutralization is alarming, necessitating expeditious detection of the variants concerned. Here, we report the development of rapid RS-CoV-2 ariants nzymatic etection (SAVED) based on CRISPR-Cas12a targeting of previously crucial variants, including Alpha, Beta, Gamma, Delta, Lambda, Mu, Kappa, and currently circulating variant of concern (VOC) Omicron and its subvariants BA.1, BA.

View Article and Find Full Text PDF

The severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) Omicron was classified as a variant of concern in November 2021. The sublineage BA.2 spreads rapidly worldwide.

View Article and Find Full Text PDF

Background: Prior to this report, variants of concern for SARS-CoV-2 were only detected from imported cases in Hong Kong.

Objective: Multiple cases of SARS-CoV-2 lineage B.1.

View Article and Find Full Text PDF

Background: Combined nasal-and-throat swabs (CNTS) is less invasive and easy to execute. CNTS also induces lower risk to healthcare workers upon collection. However, there is a lack of data on viral load assessment for population-wide testing.

View Article and Find Full Text PDF

RT-PCR is the gold standard to detect SARS-CoV-2, however, its capacity is limited. We evaluated an automated antigen detection (AAD) test, Elecsys SARS-CoV-2 Antigen (Roche, Germany), for detecting SARS-CoV-2. We compared the limit of detection (LOD) between AAD test, rapid antigen detection (RAD) test; SARS-CoV-2 Rapid Antigen Test (SD Biosensor, Korea), and in-house RT-PCR test.

View Article and Find Full Text PDF

In 2020, numerous fast-spreading severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants have been reported. These variants had unusually high genetic changes in the spike (S) protein. In an attempt to understand the genetic background of SARS-CoV-2 viruses in Hong Kong, especially before vaccination, the purpose of this study is to summarize the S protein mutations detected among coronavirus disease 2019 (COVID-19) patients in Hong Kong in 2020.

View Article and Find Full Text PDF

Background: Currently, there are two rapid antigen detection (RAD) kits from the WHO Emergency Use List for detecting SARS-CoV-2.

Objective: The Panbio COVID-19 Ag Rapid Test Device was selected to evaluate the performance for detecting SARS-CoV-2.

Study Design: Analytical sensitivity for the detection of SARS-CoV-2 virus was determined by limit of detection (LOD) using RT-PCR as a reference method.

View Article and Find Full Text PDF

Infection risks of handling specimens associated with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by public health laboratory services teams were assessed to scrutinize the potential hazards arising from the work procedures. Through risk assessments of all work sequences, laboratory equipment, and workplace environments, no aerosol-generating procedures could be identified except the procedures (mixing and transfer steps) inside biological safety cabinets. Appropriate personal protective equipment (PPE) such as surgical masks, protective gowns, face shields/safety goggles, and disposable gloves, together with pertinent safety training, was provided for laboratory work.

View Article and Find Full Text PDF

Human infection with the novel pandemic influenza A (H1N1) virus was first identified in April 2009. Two months later, the World Health Organization (WHO) had raised the pandemic level to phase 6. Rapid case identification is essential for prompt patient management and public health actions.

View Article and Find Full Text PDF

Most acute cases of infection with hepatitis E virus (HEV) in Hong Kong were autochthonous, sporadic, and occurred in older adults. All except 1 isolate belonged to genotype 4; most were phylogenetically related to swine isolates. The epidemiology is similar to that in industrialized countries, where zoonosis is the major source of HEV infection in humans.

View Article and Find Full Text PDF

The virologic test results of 415 patients with severe acute respiratory syndrome (SARS) were examined. The peak detection rate for SARS-associated coronavirus occurred at week 2 after illness onset for respiratory specimens, at weeks 2 to 3 for stool or rectal swab specimens, and at week 4 for urine specimens. The latest stool sample that was positive by reverse transcription-polymerase chain reaction (RT-PCR) was collected on day 75 while the patient was receiving intensive care.

View Article and Find Full Text PDF

We evaluated an indirect immunofluorescence assay based on virus-infected cells for detecting anti-severe acute respiratory syndrome-associated coronavirus (SARS-CoV) immunoglobulin (Ig) G antibody. All confirmed SARS cases demonstrated seroconversion or fourfold rise in IgG antibody titer; no control was positive. Sensitivity and specificity of this assay were both 100%.

View Article and Find Full Text PDF

Whether severe acute respiratory syndrome-associated coronavirus (SARS-CoV) infection can be asymptomatic is unclear. We examined the seroprevalence of SARS-CoV among 674 healthcare workers from a hospital in which a SARS outbreak had occurred. A total of 353 (52%) experienced mild self-limiting illnesses, and 321 (48%) were asymptomatic throughout the course of these observations.

View Article and Find Full Text PDF