Publications by authors named "Rick L Paul"

Three-dimensional printing and casting materials were analyzed by prompt gamma-ray activation analysis (PGAA) to determine their suitability as human tissue surrogates for the fabrication of phantoms for medical imaging and radiation dosimetry applications. Measured elemental compositions and densities of five surrogate materials simulating soft tissue and bone were used to determine radiological properties (x-ray mass attenuation coefficient and electron stopping power). When compared with radiological properties of International Commission on Radiation Units and Measurements (ICRU) materials, it was determined that urethane rubber and PLA plastic yielded the best match for soft tissue, while silicone rubber and urethane resin best simulated the properties of bone.

View Article and Find Full Text PDF

Commercial glassy carbon plates being used as absolute intensity calibration standards in small-angle X-ray scattering applications (NIST SRM 3600) have been characterized in several recent publications. This contribution adds to the characterization by measuring the hydrogen content of a plate to be (4.8 ± 0.

View Article and Find Full Text PDF

A Standard Reference Material (SRM) of seaweed, SRM 3232 Kelp Powder (Thallus laminariae) has been developed to support food and dietary supplement measurements in compliance with the Food Safety Modernization Act (FSMA) and the Dietary Supplement Health and Education Act of 1994 (DSHEA). The material was characterized for nutritional minerals, arsenic species, isomers of vitamin K, proximates, and toxic elements. Kelp is a rich source of vitamins and minerals, and it is an excellent source of dietary iodine.

View Article and Find Full Text PDF

A combination of cold neutron prompt gamma-ray activation analysis (CNPGAA) and thermal neutron (TN) PGAA was used to determine sulfur in fuel oils to develop a method to provide values for certification. CNPGAA was used to measure S/H mass ratios, and TNPGAA to measure hydrogen mass fractions. Measurements were combined to determine sulfur mass fractions (with expanded uncertainties) of 2.

View Article and Find Full Text PDF

Instrumental neutron activation analysis with both relative and k0 standardization was used in four experienced laboratories to determine element mass fractions in single-wall carbon nanotube certified reference material (CRM) SWCNT-1. Results obtained were evaluated using the National Institute of Standards and Technology (NIST) "Type B On Bias" approach and yielded consensus values in agreement with National Research Council Canada (NRCC) certified values for Fe, Co, Ni, and Mo and provided mass fraction values for 13 additional elements, namely, Na, Mg, Al, K, Ca, Ti, V, Cr, Mn, Br, La, W, and Au. In addition, prompt γ neutron activation analysis was employed to determine mass fractions of H, B, Co, Ni, and Mo.

View Article and Find Full Text PDF

Standard Reference Material 3280 Multivitamin/ Multielement Tablets was issued by the National Institute of Standards and Technology in 2009, and has certified and reference mass fraction values for 13 vitamins, 26 elements, and two carotenoids. Elements were measured using two or more analytical methods at NIST with additional data contributed by collaborating laboratories. This reference material is expected to serve a dual purpose: to provide quality assurance in support of a database of dietary supplement products and to provide a means for analysts, dietary supplement manufacturers, and researchers to assess the appropriateness and validity of their analytical methods and the accuracy of their results.

View Article and Find Full Text PDF
Article Synopsis
  • A new radiochemical neutron activation analysis (RNAA) method was developed to measure arsenic levels in standard reference materials (SRMs) for blood and urine samples.
  • Samples were freeze-dried, irradiated, and analyzed using gamma-ray spectroscopy after separating arsenic from other materials.
  • The results were standardized with values from other labs, yielding certified arsenic concentrations for several levels in the SRMs, while an information value was assigned for one level due to measurement discrepancies.
View Article and Find Full Text PDF

The structure of SnO2 nanoparticles (avg. 5 nm) with a few layers of water on the surface has been elucidated by atomic pair distribution function (PDF) methods using in situ neutron total scattering data and molecular dynamics (MD) simulations. Analysis of PDF, neutron prompt gamma, and thermogravimetric data, coupled with MD-generated surface D2O/OD configurations demonstrates that the minimum concentration of OD groups required to prevent rapid growth of nanoparticles during thermal dehydration corresponds to ~0.

View Article and Find Full Text PDF

The variations in architecture of gallium-seamed (PgCGa) and gallium-zinc-seamed (PgCGaZn) C-butylpyrogallol[4]arene nanoassemblies in solution (SANS/NMR) versus the solid state (XRD) have been investigated. Rearrangement from the solid-state spheroidal to the solution-phase toroidal shape differentiates the gallium-containing pyrogallol[4]arene nanoassemblies from all other PgCM nanocapsules studied thus far. Different structural arrangements of the metals and arenes of PgCGa versus PgCGaZn have been deduced from the different toroidal dimensions, C–H proton environments and guest encapsulation of the two toroids.

View Article and Find Full Text PDF

Several techniques were evaluated for the establishment of reliable water/moisture content of single-wall carbon nanotubes. Karl Fischer titration (KF) provides a direct measure of the water content and was used for benchmarking against results obtained by conventional oven drying, desiccation over anhydrous magnesium perchlorate as well as by thermogravimetry and prompt gamma-ray activation analysis. Agreement amongst results was satisfactory with the exception of thermogravimetry, although care must be taken with oven drying as it is possible to register mass gain after an initial moisture loss if prolonged drying time or elevated temperatures (120 °C) are used.

View Article and Find Full Text PDF

Radiochemical neutron activation analysis (RNAA) with retention on hydrated manganese dioxide (HMD) has played a key role in the certification of As in biological materials at NIST. Although this method provides very high and reproducible yields and detection limits at low microgram/kilogram levels, counting geometry uncertainties may arise from unequal distribution of As in the HMD, and arsenic detection limits may not be optimal due to significant retention of other elements. An alternate RNAA procedure with separation of arsenic by solvent extraction has been investigated.

View Article and Find Full Text PDF

Bulk silicon-germanium (SiGe) alloys and two SiGe thick films (4 and 5 microm) on Si wafers were tested with the electron probe microanalyzer (EPMA) using wavelength dispersive spectrometers (WDS) for heterogeneity and composition for use as reference materials needed by the microelectronics industry. One alloy with a nominal composition of Si0.86Ge0.

View Article and Find Full Text PDF

An instrument for cold neutron prompt gamma-ray activation analysis (PGAA), located at the NIST Center for Neutron Research (NCNR), has proven useful for the measurement of boron in a variety of materials. Neutrons, moderated by passage through liquid hydrogen at 20 K, pass through a (58)Ni coated guide to the PGAA station in the cold neutron guide hall of the NCNR. The thermal equivalent neutron fluence rate at the sample position is 9 x 10(8) cm(-2) s(-1).

View Article and Find Full Text PDF

A radiochemical neutron activation analysis procedure has been developed, critically evaluated, and shown to have the necessary sensitivity, chemical specificity, matrix independence, and precision to certify phosphorus at ion implantation levels in silicon. 32P, produced by neutron capture of 31P, is chemically separated from the sample matrix and measured using a beta proportional counter. The method is used here to certify the amount of phosphorus in SRM 2133 (Phosphorus Implant in Silicon Depth Profile Standard) as (9.

View Article and Find Full Text PDF