Rituximab, a monoclonal antibody targeting CD20 on B cells, is currently used to treat many subtypes of B cell lymphomas. However, treatment is not curative and response rates are variable. Recombinant interleukin-21 (rIL-21) is a cytokine that enhances immune effector function and affects both primary and transformed B cell differentiation.
View Article and Find Full Text PDFPurpose: To determine the magnitude of catheter displacement between time of planning and time of treatment delivery for patients undergoing high dose-rate (HDR) brachytherapy, the dosimetric impact of catheter displacement, and the ability to improve dosimetry by catheter readjustment.
Methods And Materials: Twenty consecutive patients receiving single fraction HDR brachytherapy underwent kilovoltage cone-beam CT in the treatment room before treatment. If catheter displacement was apparent, catheters were adjusted and imaging repeated.
In this work, leakage radiation from EA200 series electron applicators on Siemens Primus accelerators is quantified, and its penetration ability in water and/or the shielding material Xenolite-NL established. Initially, measurement of leakage from 10 x 10 - 25 x 25 cm2 applicators was performed as a function of height along applicator and of lateral distance from applicator body. Relative to central-axis ionization maximum in solid water, the maximum leakage in air observed with a cylindrical ion chamber with 1 cm solid water buildup cap at a lateral distance of 2 cm from the front and right sidewalls of applicators were 17% and 14%, respectively; these maxima were recorded for 18 MeV electron beams and applicator sizes of >or=20 x 20 cm2.
View Article and Find Full Text PDFPurpose: This article presents an initial investigation of the efficacy of using 1H MRS and micro-MRI as analysis techniques for irradiated GAFCHROMIC EBT radiotherapy films.
Methods: GAFCHROMIC EBT radiotherapy film was irradiated with 6 MV x rays to known doses ranging from 5 to 1000 cGy. 24 h following irradiation 1H MRS measurements were performed to access the degree of post-irradiation polymer cross-linking.
Purpose: The presence of hip prostheses results in significant image artifacts making delineation of anatomy for planning difficult with traditional kilovoltage CT images. This report presents the use of megavoltage computed tomography (MVCT) imaging acquired with a helical tomotherapy unit to plan a high-dose-rate (HDR) prostate brachytherapy treatment for a patient with bilateral hip prostheses.
Methods And Materials: A 77-year-old man presented with a localized clinical Stage T3a, Gleason 7 prostate cancer.