Importance: There are concerns that pulmonary vein isolation for atrial fibrillation may have a profound placebo effect, but no double-blind randomized clinical trials have been conducted.
Objective: To determine whether pulmonary vein isolation is more effective than a sham procedure for improving outcomes in atrial fibrillation.
Design, Setting, And Participants: Double-blind randomized clinical trial conducted at 2 tertiary centers in the UK between January 2020 and March 2024 among patients with symptomatic paroxysmal or persistent atrial fibrillation.
Pacing Clin Electrophysiol
August 2023
Introduction: Catheter ablation for atrial fibrillation (AF) reduces symptoms and improves the quality of life compared with medical treatment. It is unclear if frailty impacts on the outcome of catheter ablation in patients with symptomatic AF. We sought to evaluate the association between frailty as measured by the validated NHS electronic Frailty Index (eFI) and outcomes post-AF ablation.
View Article and Find Full Text PDFIntroduction: Pulmonary vein (PV) isolation has been shown to reduce atrial fibrillation (AF) burden and symptoms in patients. However, to date previous studies have been unblinded raising the possibility of a placebo effect to account for differences in outcomes.
Hypothesis & Methods: The objective of this study is to compare PV isolation to a sham procedure in patients with symptomatic AF.
Background: Catheter ablation of the atrioventricular node (AVN) is an effective treatment for patients with symptomatic atrial fibrillation. This study compares the success rate, procedure time, radiation time, and complication rates of retrograde left-sided (LSA) and anterograde right-sided (RSA) AVN ablation in a randomised controlled trial.
Methods: Thirty-one patients undergoing AVN ablation were randomized to either LSA (15 patients) or RSA (16 patients).
Introduction: Atrial fibrillation (AF) is suspected as the main cause of stroke in the majority of patients presenting with cryptogenic stroke (CS). Implantable loop recorders (ILR's) are indicated for detecting AF in these patients. The short term (<1 month) and long-term AF detection rates in patients inserted with an ILR immediately after CS is reported.
View Article and Find Full Text PDFBackground: Second-generation cryoballoon ablation is safe and effective in patients with paroxysmal (PAF) and persistent atrial fibrillation (AF).
Objective: This study aimed to assess the long-term clinical outcomes and freedom from AF in patients undergoing thermal-guided cryoablation without the use of an electrical mapping catheter.
Methods: All patients who had undergone thermal-guided second-generation cryoablation without electrical mapping between January 2015 and April 2018 at Eastbourne District General Hospital were retrospectively analysed.
Introduction: There is limited data using continuous monitoring to assess outcomes of atrial fibrillation (AF) ablation. This study assessed long-term outcomes of AF ablation in patients with implantable cardiac devices.
Methods: 207 patients (mean age 68.
The COVID-19 pandemic has significantly altered working practices within hospitals. This includes surgical theatres and cardiac catheter laboratories. Here we describe how we have harnessed the use of video technology to improve the running of the cardiac catheter lab in our institution, reducing the exposure of staff members to COVID-19, reducing the need for personal protective equipment (PPE) and maintaining and enhancing educational and teaching opportunities for trainees.
View Article and Find Full Text PDFBackground: Increasing evidence exists suggesting that cardiac contractility modulation therapy (CCM) improves symptoms in heart failure patients if various selection criteria are fulfilled. The aim of this study is to analyse an unselected sample of heart failure patients to establish what percentage of patients would meet the current criteria for CCM therapy.
Methods: All patients admitted to two district general hospitals in the UK in 2018 with a diagnosis of heart failure were audited for eligibility for CCM therapy.
Introduction: Current UK and international guidelines advocate the need for multidisciplinary team (MDT) discussion of selected patients undergoing either percutaneous or surgical cardiac procedures to decide the optimal treatment strategy. To date, it is unknown if using videoconference facilities is cost-effective. Therefore, we performed a cost analysis of using a high-speed internet video conferencing system compared with conventional face-to-face MDT meetings.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
March 2021
Background: Second-generation cryoballoon ablation is safe and effective in patients with persistent atrial fibrillation (AF). The aim of this study is to report the real long-term AF burden and freedom from AF post-cryoablation using continuous monitoring, and to assess whether intraoperative confirmation of pulmonary vein isolation using electrical mapping is necessary.
Methods: A total of 33 patients (mean age 75.
Objective: To investigate the accuracy of three non-invasive blood pressure (BP) devices in atrial fibrillation (AF) compared with invasive arterial BP.
Methods: One hundred patients aged 45-90 years, 63% male (50 in AF and 50 age matched controls in sinus rhythm [SR]) were identified with arterial lines measuring beat-to-beat BP fluctuation. Non-invasive BP measurements utilising the manual sphygmomanometer (MS), PulseCor R6.
Background: Sleep-disordered breathing (SDB) and atrial fibrillation (AF) are associated. This study investigated the impact of AF intervention on 6-month home sleep testing data.
Methods: Sixty-seven patients (aged 66 to 86, 53% male) with persistent AF were randomized (1:1:1) to direct current cardioversion (DCCV) (22 patients), permanent pacemaker (PPM) + atrioventricular node ablation (AVNA) + DCCV (22 patients) or AF ablation (23 patients).
Background: Resting echocardiographic measures of cardiac function such as left ventricular ejection fraction correlate poorly with exercise capacity. Assessment during exercise using measures less dependent on hemodynamic loading conditions, such as tissue Doppler imaging (TDI), may more accurately characterize the relationship between cardiac function and exercise capacity.
Methods And Results: One hundred one subjects with various cardiac diagnoses underwent exercise stress echocardiography with simultaneous cardiopulmonary gas exchange analysis.
Introduction: Studies assessing radiofrequency ablation (RFA) for atrial fibrillation (AF) performed at the time of concomitant cardiac surgery have reported high success rates. The efficacy of this treatment has primarily been determined by a single electrocardiogram (ECG) or 24-h Holter monitor at follow-up. We sought to assess the true efficacy of this procedure using prolonged cardiac rhythm monitoring.
View Article and Find Full Text PDFAims: In patients requiring permanent pacemaker implantation for sinus node disease (SND) or atrioventricular (AV) block, right ventricular (RV) pacing has been demonstrated to increase the risk of developing atrial fibrillation (AF). The effects of RV pacing in patients with paroxysmal AF are less well defined. Short- and medium-term studies have suggested no significant correlation between RV pacing and atrial fibrillation burden (AFB) measurement; we sought to assess for an effect in the long-term.
View Article and Find Full Text PDFPacing Clin Electrophysiol
June 2010
A 63-year-old man with frequent unexplained syncope was implanted with a second generation remotely monitored implantable loop recorder for continuous electrocardiogram (ECG) monitoring. He had a subsequent syncopal episode and despite accidental destruction of his patient activator, vital ECG data from the event were transmitted wirelessly, enabling a cardiac arrhythmia to be excluded. This case highlights the benefit of remote monitoring in syncope assessment, as well as a transmission system that ensures prompt analysis of the ECG data and therefore rapid optimal patient management.
View Article and Find Full Text PDFIntroduction: The beneficial effects of atrial pacing on the incidence, duration and symptomatology of paroxysmal atrial fibrillation (PAF) may be negated by increased ventricular pacing. This prospective randomised study evaluates the effect of pacing algorithms that minimise ventricular pacing (MinVP) with and without anti-AF algorithms, on AF burden (AFB) in patients with symptomatic PAF.
Methods: Patients implanted with pacemakers with MinVP capability with AFB 1-70% were enrolled.
Introduction: Accurate atrial arrhythmia discrimination is important for dual chamber pacemakers and defibrillators. The aim was to assess the accuracy of atrial arrhythmia recording using modern devices and relate this to atrial tip-to-ring (TTR) distance.
Methods: One hundred eighty-two patients (72 + or - 9 years, 55% male) with paroxysmal atrial fibrillation were enrolled and were included in the study if they had an atrial fibrillation (AF) burden of 1-50% during a monitoring phase.
Aims: Right ventricular pacing increases the risk of persistent atrial fibrillation (AF) in the long term. The effects of right ventricular pacing on paroxysmal AF (PAF) are unknown. The aim was to examine the effect of right ventricular pacing on AF burden (AFB) in patients with symptomatic drug-resistant PAF.
View Article and Find Full Text PDFPurpose: The purpose of this study is to identify the electrophysiological factors affecting symptoms in paroxysmal atrial fibrillation (PAF) using patients with paroxysmal atrial fibrillation and pacemakers with advanced atrial fibrillation (AF) diagnostics.
Methods: Seventy-nine patients (age 71.0 +/- 8.
Purpose: The study aim was to validate the closed loop stimulation (CLS) vs. accelerometer (ACC) rate-responsive sensors with electrodes placed in the right ventricular high septal (RVHS) or right ventricular apical (RVA) lead positions in patients following 'ablate and pace' therapy for persistent atrial fibrillation.
Methods: 'Ablate and pace' patients were randomised to either RVHS or RVA electrode placement with a dual sensor device.
J Am Soc Echocardiogr
July 2008
Objective: Exercise-induced changes in the synchrony of left ventricular contraction may be an important therapeutic target in heart failure. There are limited data to support the feasibility of exercise assessments. In addition, the effect of exercise on synchrony in healthy individuals is undetermined.
View Article and Find Full Text PDF