Eu(2+)-activated phosphors are being widely used in illuminations and displays. Some of these phosphors feature an extremely broad and red-shifted Eu(2+) emission band; however, convincing explanation of this phenomenon is lacking. Here we report a new localized/delocalized emitting state of Eu(2+) ions in a new hexagonal EuAl(2)O(4) phosphor whose Eu(2+) luminescence exhibits a very large bandwidth and an extremely large Stokes shift.
View Article and Find Full Text PDFInt J Environ Res Public Health
December 2010
In the United States, smoking is the leading cause of death - having a mortality rate of approximately 435,000 people in 2000-accounting for 8.1% of all US deaths recorded that year. Consequently, we analyzed the Delaware Hospital Discharge Database, and identified state and non-state residents discharged with AMI or asthma for the years 1999 to 2004.
View Article and Find Full Text PDFOptical dephasing of Pr3+ and Tm3+ ions doped in transparent oxyfluoride glass ceramics was studied with the two-pulse photon echo technique. It was found that the dephasing time of rare earth ions is dramatically less in nanocrystals embedded in a glass matrix than in bulk crystals. A quasi-linear temperature dependence obtained at low temperatures proved that the long-range interaction of the ions inside the nanocrystals with the two level systems of the glass matrix dominates the optical dephasing.
View Article and Find Full Text PDFAortic arch atherosclerosis is associated with an increased risk of stroke or TIA. Up to now, transesophageal echocardiography has been the standard method for diagnosing protruding and/or mobile aortic arch atherosclerosis. We report a case where a mobile aortic arch atheroma was diagnosed using transthoracic echo in a patient with a recent stroke.
View Article and Find Full Text PDFTo test the hypothesis that the full extent of in vitro cell lysis due to ultrasound becomes evident with time lapse following insonation, human erythrocytes (2% hematocrit) in autologous plasma were mixed with Albunex(R), a pulse echo contrast agent, and exposed to 1-MHz, continuous-wave ultrasound (US) (5 W/cm(2) SPTA intensity) for 60 seconds while in a rotating (200 rpm) dialysis membrane vessel. Exposed and sham-exposed samples were subsequently assayed for hemolysis colorimetrically, either immediately or after a delay of 3 hours. Hemolysis was dependent on the interval between US exposure and assay, with significantly greater lysis evident with delayed assay.
View Article and Find Full Text PDFEchocardiographic left ventricular mass (LVM) estimates are strong predictors of subsequent mortality and cardiovascular events. It is known that blood pressure (BP), weight (WT), and age are significantly correlated with LVM. We hypothesized that stroke volume (SV) measured by Doppler echocardiography would also be correlated with LVM.
View Article and Find Full Text PDF