Publications by authors named "Richard Nuckols"

Purpose Of Review: While wearable robotics is expanding within clinical settings, particularly for neurological rehabilitation, there is still a lack of consensus on how to effectively assess the performance of these devices. This review focuses on the most common metrics, whose selection and design are crucial for optimizing treatment outcomes and potentially improve the standard care.

Recent Findings: The literature reveals that while wearable robots are equipped with various embedded sensors, most studies still rely on traditional, nontechnological methods for assessment.

View Article and Find Full Text PDF

Background: During inpatient rehabilitation, physical therapists (PTs) often need to manually advance patients' limbs, adding physical burden to PTs and impacting gait retraining quality. Different electromechanical devices alleviate this burden by assisting a patient's limb advancement and supporting their body weight. However, they are less ideal for neuromuscular engagement when patients no longer need body weight support but continue to require assistance with limb advancement as they recover.

View Article and Find Full Text PDF

The human body constantly experiences mechanical loading. However, quantifying internal loads within the musculoskeletal system remains challenging, especially during unconstrained dynamic activities. Conventional measures are constrained to laboratory settings, and existing wearable approaches lack muscle specificity or validation during dynamic movement.

View Article and Find Full Text PDF

Brightness-mode (B-mode) ultrasound has been used to measure in vivo muscle dynamics for assistive devices. Estimation of fascicle length from B-mode images has now transitioned from time-consuming manual processes to automatic methods, but these methods fail to reach pixel-wise accuracy across extended locomotion. In this work, we aim to address this challenge by combining a U-net architecture with proven segmentation abilities with an LSTM component that takes advantage of temporal information to improve validation accuracy in the prediction of fascicle lengths.

View Article and Find Full Text PDF

Background: Soft robotic exosuits can provide partial dorsiflexor and plantarflexor support in parallel with paretic muscles to improve poststroke walking capacity. Previous results indicate that baseline walking ability may impact a user's ability to leverage the exosuit assistance, while the effects on continuous walking, walking stability, and muscle slacking have not been evaluated. Here we evaluated the effects of a portable ankle exosuit during continuous comfortable overground walking in 19 individuals with chronic hemiparesis.

View Article and Find Full Text PDF

Chronic impairment in the paretic ankle following stroke often requires that individuals use compensatory patterns such as asymmetric propulsion to achieve effective walking speeds needed for community engagement. Ankle exosuit assistance can provide ankle biomechanical benefit in the lab, but such environments inherently limit the amount of practice available. Community walking studies without exosuits can provide massed practice and benefit walking speed but are limited in their ability to assist proper mechanics.

View Article and Find Full Text PDF

In the field of wearable robotics, assistance needs to be individualized for the user to maximize benefit. Information from muscle fascicles automatically recorded from brightness mode (B-mode) ultrasound has been used to design assistance profiles that are proportional to the estimated muscle force of young individuals. There is also a desire to develop similar strategies for older adults who may have age-altered physiology.

View Article and Find Full Text PDF

Exosuits have the potential to assist locomotion in both healthy and pathological populations, but the effect of exosuit assistance on the underlying muscle-tendon tissue loading is not yet understood. In this study, we used shear wave tensiometers to characterize the modulation of Achilles tendon force with load carriage and exosuit assistance at the ankle. When walking (1.

View Article and Find Full Text PDF

Background: Ankle-targeting resistance training for improving plantarflexion function during walking increases rehabilitation intensity, an important factor for motor recovery after stroke. However, understanding of the effects of resisting plantarflexion during stance on joint kinetics and muscle activity-key outcomes in evaluating its potential value in rehabilitation-remains limited. This initial study uses a unilateral exosuit that resists plantarflexion during mid-late stance in unimpaired individuals to test the hypotheses that when plantarflexion is resisted, individuals would (1) increase plantarflexor ankle torque and muscle activity locally at the resisted ipsilateral ankle, but (2) at higher forces, exhibit a generalized response that also uses the unresisted joints and limb.

View Article and Find Full Text PDF

Powered ankle exoskeletons that apply assistive torques with optimized timing and magnitude can reduce metabolic cost by ∼10% compared to normal walking. However, finding individualized optimal control parameters is time consuming and must be done independently for different walking modes (e.g.

View Article and Find Full Text PDF

Lower-limb wearable robotic devices can improve clinical gait and reduce energetic demand in healthy populations. To help enable real-world use, we sought to examine how assistance should be applied in variable gait conditions and suggest an approach derived from knowledge of human locomotion mechanics to establish a 'roadmap' for wearable robot design. We characterized the changes in joint mechanics during walking and running across a range of incline/decline grades and then provide an analysis that informs the development of lower-limb exoskeletons capable of operating across a range of mechanical demands.

View Article and Find Full Text PDF

Background: Elastic ankle exoskeletons with intermediate stiffness springs in parallel with the human plantarflexors can reduce the metabolic cost of walking by ~ 7% at 1.25 m s. In a move toward 'real-world' application, we examined whether the unpowered approach has metabolic benefit across a range of walking speeds, and if so, whether the optimal exoskeleton stiffness was speed dependent.

View Article and Find Full Text PDF

In individuals with motor impairments such as those post-stroke or with cerebral palsy, the function of the knee extensors may be affected during walking, resulting in decreased mobility. We have designed a lightweight, hinge-free wearable robot combining soft textile exosuit components with integrated rigid components, which assists knee extension when needed but is otherwise highly transparent to the wearer. The exosuit can apply a wide range of assistance profiles using a flexible multi-point reference trajectory generator.

View Article and Find Full Text PDF

Exoskeletons that improve locomotion economy typically are engineered to reduce users' limb joint mechanical work or moments. Yet, limb joint dynamics do not necessarily reflect muscle dynamics, which dictate whole-body metabolic energy expenditure. Here, we hypothesize that exoskeletons primarily reduce user metabolic energy expenditure across locomotion conditions by reducing active muscle volume.

View Article and Find Full Text PDF

Background: Ankle exoskeletons offer a promising opportunity to offset mechanical deficits after stroke by applying the needed torque at the paretic ankle. Because joint torque is related to gait speed, it is important to consider the user's gait speed when determining the magnitude of assistive joint torque. We developed and tested a novel exoskeleton controller for delivering propulsive assistance which modulates exoskeleton torque magnitude based on both soleus muscle activity and walking speed.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessiont0btqd9isjnnnk2ghje3afko79h9hq1f): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once