Publications by authors named "Richard Mallory"

Purpose: This article reviews toxicity outcomes for a series of patients treated with stereotactic radiosurgery for trigeminal neuralgia, focusing on dose to the brainstem, trigeminal nerve, and Meckel's cave as possible explanatory variables for the development of the most common posttreatment neuropathy, facial numbness.

Methods And Materials: A retrospective review of 136 cases treated with CyberKnife radiosurgery for trigeminal neuralgia was performed. Dose was initially (cohort 1) prescribed to 57 to 64 Gy covering a 6-mm cylindrical shaped target volume ≥2 mm from the dorsal root entry zone.

View Article and Find Full Text PDF

Purpose: SBRT treatment of two separate lung lesions via single-isocenter/multi-target (SIMT) plan on Halcyon RDS could improve patient comfort, compliance, patient throughput, and clinic efficiency. However, aligning two separate lung lesions synchronously via a single pre-treatment CBCT scan on Halcyon can be difficult due to rotational patient setup errors. Thus, to quantify the dosimetric impact, we simulated loss of target(s) coverage due to small, yet clinically observable rotational patient setup errors on Halcyon for SIMT treatments.

View Article and Find Full Text PDF

Stereotactic body radiotherapy (SBRT) treatment of oligometastatic lesions via single-isocenter/multi-target (SIMT) plan is more efficient than using multi-isocenter/multitarget SBRT. This study quantifies the spatial positioning accuracy of 2 commercially available LINAC systems for SIMT treatment pertaining to the potential amplification of error as a function of the target's distance-to-isocenter. We compare the Ring-Gantry Halcyon LINAC equipped with the fast iterative conebeam-CT (iCBCT) for image-guided SIMT treatment, and the SBRT-dedicated C-Arm TrueBeam with standard pretreatment CBCT imaging.

View Article and Find Full Text PDF

This study aims to report on the clinical validation and feasibility of utilizing a novel fully automated treatment planning and delivery system, HyperArc VMAT stereotactic radiosurgery (SRS) for glomus jugulare tumors (GJT). Independent dose verification of the HyperArc module via the MD Anderson's SRS head phantom irradiation and credentialing results showed compliance with the SRS treatment requirements per IROC MD Anderson's standard. Following the Alliance clinical trial, AAPM, RTOG protocols, and QUANTEC requirements, utilizing selected three-partial arc geometry of HyperArc module on TrueBeam Linac with 6MV-FFF beam, GJT SRS plans were generated for nine previously treated Gamma Knife (GK) radiosurgery patients using advanced Acuros-based algorithm to account for tissue inhomogeneity corrections and frameless immobilization with Q-fix mask and Encompass device insert.

View Article and Find Full Text PDF

For fast, safe, and effective management of large and bulky (≥8 cm) non-resectable tumors, we have developed a conebeam CT-guided three-dimensional (3D)-conformal MLC-based spatially fractionated radiation therapy (SFRT) treatment. Using an in-house MLC-fitting algorithm, Millennium 120 leaves were fitted to the gross tumor volume (GTV) generating 1-cm diameter holes at 2-cm center-to-center distance at isocenter. SFRT plans of 15 Gy were generated using four to six coplanar crossfire gantry angles 60° apart with a 90° collimator, differentially weighted with 6- or 10-MV beams.

View Article and Find Full Text PDF

Purpose: To demonstrate the plan quality and delivery efficiency of volumetric-modulated arc therapy (VMAT) with the Halcyon Linac ring delivery system (RDS) in the treatment of single-isocenter/two-lesion lung stereotactic body radiation therapy (SBRT).

Materials/methods: Sixteen previously treated non-coplanar VMAT single-isocenter/two-lesion lung SBRT plans delivered with SBRT-dedicated C-arm TrueBeam Linac were selected. Prescribed dose was 50 Gy to each lesion over five fractions with treatment delivery every other day and AcurosXB algorithm as the final dose calculation algorithm.

View Article and Find Full Text PDF