Publications by authors named "Richard M Lindstrom"

Nearly fifty years ago, two landmark papers appeared that should have cured the problem of ambiguous uncertainty statements in published data. Eisenhart's paper in called for statistically meaningful numbers, and Currie's paper revealed the wide range in common definitions of detection limit. Confusion and worse can result when uncertainties are misinterpreted or ignored.

View Article and Find Full Text PDF

For the ultimate sensitivity in trace radiochemical analysis, the radiation detector must have high efficiency and low background. A low-background gamma-ray spectrometer in regular use at NIST for over twenty years is being supplemented by a new system, improved in several ways. The new detector is much larger, a shield of iron reduces cosmic neutron background compared with lead, large plastic scintillators reduce the muon continuum background, and a digital data acquisition system gives new opportunities for optimization.

View Article and Find Full Text PDF

An accurate and precise measurement of selenium in Standard Reference Material (SRM) 3149, a primary calibration standard for the quantitative determination of selenium, has been accomplished by instrumental neutron activation analysis (INAA) in order to resolve a question arising during the certification process of the standard. Each limiting factor of the uncertainty in the activation analysis, including the sample preparation, irradiation, and γ-ray spectrometry steps, has been carefully monitored to minimize the uncertainty in the determined mass fraction. Neutron and γ-ray self-shielding within the elemental selenium INAA standards contributed most significantly to the uncertainty of the measurement.

View Article and Find Full Text PDF

Standard Reference Material (SRM) 1849 Infant/Adult Nutritional Formula has been issued by the National Institute of Standards and Technology (NIST) as a replacement for SRM 1846 Infant Formula, issued in 1996. Extraction characteristics of SRM 1846 have changed over time, as have NIST's analytical capabilities. While certified mass fraction values were provided for five constituents in SRM 1846 (four vitamins plus iodine), certified mass fraction values for 43 constituents are provided in SRM 1849 (fatty acids, elements, and vitamins) and reference mass fraction values are provided for an additional 43 constituents including amino acids and nucleotides, making it the most extensively characterized food-matrix SRM available from NIST.

View Article and Find Full Text PDF

We report further measurements of lithium and boron bound to human plasma proteins using the techniques of gel chromatography, thermal-neutron activation, and high-sensitivity helium isotope mass spectrometry. The plasma sample was donated by a bipolar patient who had never been on lithium therapy. The plasma lithium-binding pattern for the bipolar patient is distinctly different from that previously observed in this laboratory for plasma donated by a normal individual.

View Article and Find Full Text PDF

This study was undertaken to compare endogenous lithium concentrations in human blood and its components from normal donors versus bipolar patients. The patients were not on lithium therapy at the time that the blood samples were donated and had not received any lithium therapy for at least 2 yr. Blood components were separated by centrifugation.

View Article and Find Full Text PDF
Prompt-Gamma Activation Analysis.

J Res Natl Inst Stand Technol

January 1993

A permanent, full-time instrument for prompt-gamma activation analysis is nearing completion as part of the Cold Neutron Research Facility (CNRF). The design of the analytical system has been optimized for high gamma detection efficiency and low background, particularly for hydrogen. Because of the purity of the neutron beam, shielding requirements are modest and the scatter-capture background is low.

View Article and Find Full Text PDF