The 9th GCCClosed Forum was held just prior to the 2015 Workshop on Recent Issues in Bioanalysis (WRIB) in Miami, FL, USA on 13 April 2015. In attendance were 58 senior-level participants, from eight countries, representing 38 CRO companies offering bioanalytical services. The objective of this meeting was for CRO bioanalytical representatives to meet and discuss scientific and regulatory issues specific to bioanalysis.
View Article and Find Full Text PDFThe 8th GCC Closed Forum for Bioanalysis was held in Baltimore, MD, USA on 5 December 2013, immediately following the 2013 AAPS Workshop (Crystal City V): Quantitative Bioanalytical Methods Validation and Implementation--The 2013 Revised FDA Guidance. This GCC meeting was organized to discuss the contents of the draft revised FDA Guidance on bioanalytical method validation that was published in September 2013 and consolidate the feedback of the GCC members. In attendance were 63 senior-level participants, from seven countries, representing 46 bioanalytical CRO companies/sites.
View Article and Find Full Text PDFThe topic of incurred sample stability (ISS) has generated considerable discussion within the bioanalytical community in recent years. The subject was an integral part of the seventh annual Workshop on Recent Issues in Bioanalysis (WRIB) held in Long Beach, CA, USA, in April 2013, and at the Global CRO Council for Bioanalysis (GCC) meeting preceding it. Discussion at both events focused on the use of incurred samples for ISS purposes in light of results from a recent GCC survey completed by member companies.
View Article and Find Full Text PDFConsensus practices and regulatory guidance for liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) assays of small molecules are more aligned globally than for any of the other bioanalytical techniques addressed by the Global Bioanalysis Consortium. The three Global Bioanalysis Consortium Harmonization Teams provide recommendations and best practices for areas not yet addressed fully by guidances and consensus for small molecule bioanalysis. Recommendations from all three teams are combined in this report for chromatographic run quality, validation, and sample analysis run acceptance.
View Article and Find Full Text PDFThe 5th GCC in Barcelona (Spain) and 6th GCC in San Antonio (TX, USA) events provided a unique opportunity for CRO leaders to openly share opinions and perspectives, and to agree upon recommendations on biomarker bioanalytical method validation.
View Article and Find Full Text PDFAn open letter written by the Global CRO Council for Bioanalysis (GCC) describing the GCC survey results on stability data from co-administered and co-formulated drugs was sent to multiple regulatory authorities on 14 December 2011. This letter and further discussions at different GCC meetings led to subsequent recommendations on this topic of widespread interest within the bioanalytical community over the past 2 years.
View Article and Find Full Text PDFRecent studies have shown a correlation between 5-lipoxygenase (5-LO) pathway up-regulation and cardiovascular risk. Despite the existence of several assays for products of the 5-LO pathway, a reliable method for clinical determination of 5-LO activity remains to be established. In the present communication, we report conditions that allow measurement of 5-hydroxyeicosatetraenoic acid (5-HETE) and leukotriene B(4) (LTB(4)) in peripheral blood mononuclear cells (PBMCs) isolated from the blood of atherosclerosis patients before and after stimulation by the calcium ionophore, A23187.
View Article and Find Full Text PDFA sensitive and selective liquid chromatography tandem mass spectrometry (LC/MS/MS) method for the determination of atomoxetine and its metabolites (4-hydroxyatomoxetine, N-des-methylatomoxetine, and 4-hydroxyatomoxetine-O-glucuronide) has been developed for human plasma and urine. Using stable-labeled internal standards, the method proved to be accurate and precise for the analytes in all species, resulting in inter-batch accuracy (percent relative error, %RE) within 100+/-13% and inter-batch precision (relative standard deviation, %RSD) within 11%. Stability was demonstrated for the analytes in neat solutions and the reconstitution solvent, as well as plasma and urine (with or without the deconjugation reagent).