Publications by authors named "Richard G P Lopata"

Currently, abdominal aortic aneurysms (AAAs) are treated based on the diameter of the aorta, however, a more robust patient-specific marker is needed. The mean thickness of the wall is a potential indicator for AAA rupture risk, which varies significantly within and between patients. So far, regional thickness has not been used in previous rupture risk analysis studies, since it is challenging to measure in CT, MRI, and non-invasive ultrasound (US).

View Article and Find Full Text PDF

This study demonstrates high volume rate bistatic 3-D vascular strain imaging, to overcome well-known challenges caused by the anisotropic resolution and contrast inherent to ultrasound imaging. Approach. Using two synchronized 32x32 element matrix arrays (3.

View Article and Find Full Text PDF

Time-resolved three-dimensional ultrasound (3D + t US) is a promising imaging modality for monitoring abdominal aortic aneurysms (AAAs), providing their 3D geometry and motion. The lateral contrast of US is poor, a well-documented drawback which multi-perspective (MP) imaging could resolve. This study aims to show the feasibility of in vivo multi-perspective 3D + t ultrasound imaging of AAAs for improving the image contrast and displacement accuracy.

View Article and Find Full Text PDF

Aims: Urbanization is related to non-communicable diseases such as congestive heart failure (CHF). Understanding the influence of diverse living environments on physiological variables such as heart rate variability (HRV) in patients with chronic cardiac disease may contribute to more effective lifestyle advice and telerehabilitation strategies. This study explores how machine learning (ML) models can predict HRV metrics, which measure autonomic nervous system responses to environmental attributes in uncontrolled real-world settings.

View Article and Find Full Text PDF

Abdominal aortic aneurysms (AAAs) are rupture-prone dilatations of the aorta. In current clinical practice, the maximal diameter of AAAs is monitored with 2D ultrasound to estimate their rupture risk. Recent studies have shown that 3-dimensional and mechanical AAA parameters might be better predictors for aneurysm growth and rupture than the diameter.

View Article and Find Full Text PDF

In this paper we introduce multi-aperture ultrasound imaging and elastography of the abdominal aorta. Monitoring of the geometry and growth of abdominal aortic aneurysms (AAA) is paramount for risk stratification and intervention planning. However, such an assessment is limited by the lateral lumen-wall contrast and resolution of conventional ultrasound.

View Article and Find Full Text PDF

High frame rate ultrasound (US) imaging techniques in 3D are promising tools for capturing abdominal aortic aneurysms (AAAs) over time, however, with the limited number of channel-to-element connections current footprints are small, which limits the field of view. Moreover, the maximal steering angle of the ultrasound beams in transmit and the maximal receptance angle in receive are insufficient for capturing the curvy shape of the AAA. Therefore, an approach is needed towards large arrays.

View Article and Find Full Text PDF

In multiaperture ultrasound, several ultrasound probes with different insonification angles are combined to increase the field of view and angular coverage of image structures. A full reconstruction incorporating all possible combinations of transmitting and receiving probes has been shown to improve resolution, contrast, and angular coverage beyond what can be achieved by the registration of single images from different probes. A major challenge in multiaperture imaging is the correct determination of relative probe locations.

View Article and Find Full Text PDF

Cardiovascular strain imaging is continually improving due to ongoing advances in ultrasound acquisition and data processing techniques. The phantoms used for validation of new methods are often burdensome to make and lack flexibility to vary mechanical and acoustic properties. Simulations of US imaging provide an alternative with the required flexibility and ground truth strain data.

View Article and Find Full Text PDF

The heterogeneity of progression of abdominal aortic aneurysms (AAAs) is not well understood. This study investigates which geometrical and mechanical factors, determined using time-resolved 3D ultrasound (3D + t US), correlate with increased growth of the aneurysm. The AAA diameter, volume, wall curvature, distensibility, and compliance in the maximal diameter region were determined automatically from 3D + t echograms of 167 patients.

View Article and Find Full Text PDF

In the last decade, many advances have been made in high frame rate 3-D ultrasound imaging, including more flexible acquisition systems, transmit (TX) sequences, and transducer arrays. Compounding multiangle transmits of diverging waves has shown to be fast and effective for 2-D matrix arrays, where heterogeneity between transmits is key in optimizing the image quality. However, the anisotropy in contrast and resolution remains a drawback that cannot be overcome with a single transducer.

View Article and Find Full Text PDF

Abdominal ultrasound image quality is hampered by phase aberration, that is mainly caused by the large speed-of-sound (SoS) differences between fat and muscle tissue in the abdominal wall. The mismatch between the assumed and actual SoS distribution introduces general blurring of the ultrasound images, and acoustic refraction can lead to geometric distortion of the imaged features. Large aperture imaging or dual-transducer imaging can improve abdominal imaging at deep locations by providing increased contrast and resolution.

View Article and Find Full Text PDF

Despite the notable recent developments in the field of remote photoplethysmography (rPPG), extracting a reliable pulse rate variability (PRV) signal still remains a challenge. In this study, eight image-based photoplethysmography (iPPG) extraction methods (GRD, AGRD, PCA, ICA, LE, SPE, CHROM, and POS) were compared in terms of pulse rate (PR) and PRV features. The algorithms were made robust for motion and illumination artifacts by using ad hoc pre- and postprocessing steps.

View Article and Find Full Text PDF

Rupture risk estimation of abdominal aortic aneurysm (AAA) patients is currently based on the maximum diameter of the AAA. Mechanical properties that characterize the mechanical state of the vessel may serve as a better rupture risk predictor. Non-electrocardiogram-gated (non-ECG-gated) freehand 2D ultrasound imaging is a fast approach from which a reconstructed volumetric image of the aorta can be obtained.

View Article and Find Full Text PDF

Ultrasound (US) imaging is a medical imaging modality that uses the reflection of sound in the range of 2-18 MHz to image internal body structures. In US, the frequency bandwidth (BW) is directly associated with image resolution. BW is a property of the transducer and more bandwidth comes at a higher cost.

View Article and Find Full Text PDF

Methods for patient-specific abdominal aortic aneurysm (AAA) progression monitoring and rupture risk assessment are widely investigated. Three-dimensional ultrasound can visualize the AAA's complex geometry and displacement fields. However, ultrasound has a limited field of view and low frame rate (i.

View Article and Find Full Text PDF

Significance: Physics-based simulations of photoacoustic (PA) signals are used to validate new methods, to characterize PA setups and to generate training datasets for machine learning. However, a thoroughly validated PA simulation toolchain that can simulate realistic images is still lacking.

Aim: A quantitative toolchain was developed to model PA image acquisition in complex tissues, by simulating both the optical fluence and the acoustic wave propagation.

View Article and Find Full Text PDF

Left ventricular (LV) strains are typically represented with respect to the imaging axes. Contraction within the myocardium occurs along myofibres, which vary in orientation. Therefore, a mismatch exists between the direction in which strain is calculated and that in which contraction occurs.

View Article and Find Full Text PDF

Lightweight segmentation models are becoming more popular for fast diagnosis on small and low cost medical imaging devices. This study focuses on the segmentation of the left ventricle (LV) in cardiac ultrasound (US) images. A new lightweight model [LV network (LVNet)] is proposed for segmentation, which gives the benefits of requiring fewer parameters but with improved segmentation performance in terms of Dice score (DS).

View Article and Find Full Text PDF

Purpose: Various parameters of mechanical dyssynchrony have been proposed to improve patient selection criteria for cardiac resynchronization therapy, but sensitivity and specificity are lacking. However, echocardiographic parameters are consistently investigated at rest, whereas heart failure (HF) symptoms predominately manifest during submaximal exertion. Although strain-based predictors of response are promising, feasibility and reproducibility during exercise has yet to be demonstrated.

View Article and Find Full Text PDF

Ultrasound (US) imaging is used to assess cardiac disease by assessing the geometry and function of the heart utilizing its high spatial and temporal resolution. However, because of physical constraints, drawbacks of US include limited field-of-view, refraction, resolution and contrast anisotropy. These issues cannot be resolved when using a single probe.

View Article and Find Full Text PDF

In the above article [1], one error, (1), was found which has an impact on the results and interpretation of the image quality that was described in four sentences, (2)-(5). This correction does not mitigate the overall conclusion of this work, but does positively support improvements of the proposed method (multi-perspective ultrafast imaging) in comparison with the standard method (focused line-by-line imaging).

View Article and Find Full Text PDF

Cardiovascular diseases (CVDs) remain the leading cause of death worldwide. An effective management and treatment of CVDs highly relies on accurate diagnosis of the disease. As the most common imaging technique for clinical diagnosis of the CVDs, US imaging has been intensively explored.

View Article and Find Full Text PDF

Knowledge of aneurysm geometry and local mechanical wall parameters using ultrasound (US) can contribute to a better prediction of rupture risk in abdominal aortic aneurysms (AAAs). However, aortic strain imaging using conventional US is limited by the lateral lumen-wall contrast and resolution. In this study, ultrafast multiperspective bistatic (MP BS) imaging is used to improve aortic US, in which two curved array transducers receive simultaneously on each transmit event.

View Article and Find Full Text PDF