Publications by authors named "Richard Abben"

Article Synopsis
  • The study evaluates the long-term performance and safety of the extravascular implantable cardioverter-defibrillator (EV ICD) after initial findings showed its effectiveness for 6 months.
  • A total of 316 patients were enrolled, with a successful implant in 299 cases, experiencing various arrhythmic events that were effectively treated using antitachycardia pacing (ATP) and shocks.
  • The results indicated high success rates for both ATP (77.1%) and shock therapy (100%), with low rates of complications and inappropriate shocks over the three-year study period.
View Article and Find Full Text PDF

Background: Patients with ischemic cardiomyopathy, non-left bundle branch block, or QRS duration <150 ms have a lower response rate to cardiac resynchronization therapy (CRT) than did other indicated patients. The ECG Belt system (EBS) is a novel surface mapping system designed to measure electrical dyssynchrony via the standard deviation of the activation times of the left ventricle.

Objectives: The objectives of this study were to evaluate the efficacy of the EBS in patients less likely to respond to CRT and to determine whether EBS use in lead placement guidance and device programming was superior to standard CRT care.

View Article and Find Full Text PDF

Background: The extravascular implantable cardioverter-defibrillator (ICD) has a single lead implanted substernally to enable pause-prevention pacing, antitachycardia pacing, and defibrillation energy similar to that of transvenous ICDs. The safety and efficacy of extravascular ICDs are not yet known.

Methods: We conducted a prospective, single-group, nonrandomized, premarket global clinical study involving patients with a class I or IIa indication for an ICD, all of whom received an extravascular ICD system.

View Article and Find Full Text PDF

Percutaneous and surgical procedures intended to potentially cure atrial fibrillation require creating lines of conduction block in specific locations throughout the atrial chambers. In patients presenting with recurrent atrial fibrillation, repeat procedures are often performed, resulting in more extensive regions of conduction block and the potential for regions of dissociated atrial rhythms. The present case describes a patient post-multiple ablation procedures who presented with a symptomatic atrial arrhythmia, the mechanism of which was hidden by the presence of extensive atrial dissociation.

View Article and Find Full Text PDF

In patients receiving cardiac resynchronization therapy (CRT), the left ventricular electrode cannot always be positioned in the preferred lateral or posterolateral locations due to technical factors and anatomic variations in the coronary sinus. Recent reports also suggest that CRT outcomes are improved by pacing the site of latest dyssynchrony and accessing these regions is not always possible. We report the utility of applying a technique described in the interventional literature over the past 3 years, effectively traversing and dilating collateral channels.

View Article and Find Full Text PDF