Publications by authors named "Ricardo Manrique"

Background And Objective: We attempt to reduce the ischemic time during implantation of the donor heart in the bicaval bipulmonary orthotopic position using normothermic beating heart and thus, facilitate the transplanted heart adaptation to the recipient. This study presents a small experience about a new strategy of myocardial protection during heart transplant.

Methods: In cardiopulmonary bypass, the aorta anastomosis was done first, allowing the coronary arteries to receive blood flow and the recovering of the beats.

View Article and Find Full Text PDF

Objective: The objective is to present the results of the application this device in experimental animals unloading only the left ventricle.

Methods: Between June 2002 and October 2009, were implanted in 27 calfs with age between 2½ to 4 months and 80 to 100 kg of weight, with general anaesthesia and controled ventilation, by mean of left thoracotomy a cannula in the apex of VE and a lateral anastomose of a GTFE vascular graft tube in the descending portion of the thoracic aorta, both connected to the device implanted below the diaphragm in the subcutaneous (24) and intrathoracic (three). The cardiopulmonary bypass (BP) was used in five calves, and directly introduce the outflow cannula in 22.

View Article and Find Full Text PDF

Background: Evaluation of pulmonary artery pressure just before transplanting with sodium nitroprusside may allow conversion to orthotopic technique.

Methods: Between 1992 and 2007, 228 transplants were performed systematically and this was used in seven patients with preoperative hemodynamic evaluation: Pre NP (mmHg) Post NP (mmHg) Systolic systemic blood pressure (PSAS) 108-78 (101.7 ± 10.

View Article and Find Full Text PDF

A new digital computer mock circulatory system has been developed in order to replicate the physiologic and pathophysiologic characteristics of the human cardiovascular system. The computer performs the acquisition of pressure, flow, and temperature in an open loop system. A computer program has been developed in Labview programming environment to evaluate all these physical parameters.

View Article and Find Full Text PDF

Introduction: This paper addresses an original project that encompasses the conception, development and clinical application of a helical bypass pump called the Spiral Pump, that uses the association of centrifugal and axial propulsion forces based de the Archimedes principle. This project has obtained a Brazilian Patent and an International Preliminary Report, defining it as an invention.

Methods: The aim of this work was to evaluate the hemodynamic capacity and the impact of its application on blood cells by means of experimental in vitro tests, including hydrodynamic efficiency, effect on hemolysis and flow visualization.

View Article and Find Full Text PDF

A 23-year-old-female patient had undergone a very successful gastric banding surgery to treat obesity. Six months later she began to present recurrent syncope due to very frequent, intermittent high-degree AV block referred to as pacemaker implantation. The electrophysiological study showed impaired AV nodal conduction but the His-Purkinje conduction was preserved.

View Article and Find Full Text PDF