Am J Physiol Heart Circ Physiol
October 2024
Fractional flow reserve (FFR) measurements are recommended for assessing hemodynamic coronary stenosis severity. Intracoronary ECG (icECG) is easily obtainable and highly sensitive in detecting myocardial ischemia due to its close vicinity to the myocardium. We hypothesized that the remission time of myocardial ischemia on icECG after a controlled coronary occlusion accurately detects hemodynamically relevant coronary stenosis.
View Article and Find Full Text PDFElectrocochleography (ECochG) is increasingly used to monitor the inner ear function of cochlear implant (CI) patients during surgery. Current ECochG-based trauma detection shows low sensitivity and specificity and depends on visual analysis by experts. Trauma detection could be improved by including electric impedance data recorded simultaneously with the ECochG.
View Article and Find Full Text PDFFront Cardiovasc Med
September 2022
Introduction: Since its first implementation in 1985, intracoronary (ic) electrocardiogram (ECG) has shown ample evidence for its diagnostic value given the higher sensitivity for myocardial ischemia detection in comparison to surface ECG. However, a lack of online systems to quantitatively analyze icECG in real-time prevents its routine use. The present study aimed to develop and validate an autonomous icECG analyzing algorithm.
View Article and Find Full Text PDFAnn Noninvasive Electrocardiol
September 2019
Aims: Supraventricular arrhythmia diagnosis using the surface electrocardiogram (sECG) is often cumbersome due to limited atrial signal quality. In some instances, use of esophageal electrocardiography (eECG) may facilitate the diagnosis. Here, we present a novel approach to reconstruct cardiac activation maps from eECG recordings.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
August 2018
The rapid progress of invasive therapeutic options for cardiac arrhythmias increases the need for accurate diagnostics. The surface electrocardiogram (ECG) is still the standard of noninvasive diagnostics but lacks atrial signal resolution. By contrast, esophageal electrocardiography (EECG) yields atrial signals of high amplitude and with a high signal-to-noise ratio.
View Article and Find Full Text PDFPurpose: Paroxysmal atrial fibrillation (PAF) often remains undiagnosed. Long-term surface ECG is used for screening, but has limitations. Esophageal ECG (eECG) allows recording high quality atrial signals, which were used to identify markers for PAF.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
February 2016
Long-term electrocardiogram (ECG) signals might suffer from relevant baseline disturbances during physical activity. Motion artifacts in particular are more pronounced with dry surface or esophageal electrodes which are dedicated to prolonged ECG recording. In this paper we present a method called baseline wander tracking (BWT) that tracks and rejects strong baseline disturbances and avoids concurrent saturation of the analog front-end.
View Article and Find Full Text PDFLong-term electrocardiogram (ECG) often suffers from relevant noise. Baseline wander in particular is pronounced in ECG recordings using dry or esophageal electrodes, which are dedicated for prolonged registration. While analog high-pass filters introduce phase distortions, reliable offline filtering of the baseline wander implies a computational burden that has to be put in relation to the increase in signal-to-baseline ratio (SBR).
View Article and Find Full Text PDFBackground: Computer supported, interactive e-learning systems are widely used in the teaching of physiology. However, the currently available complimentary software tools in the field of the physiology of cardiovascular mechanics have not yet been adapted to the latest systems software. Therefore, a simple-to-use replacement for undergraduate and graduate students' education was needed, including an up-to-date graphical software that is validated and field-tested.
View Article and Find Full Text PDF