Publications by authors named "Rene Daher"

Aim: This nationwide population-based cohort study aimed to assess the incidence of implant complication treatments, including implant removal procedures and peri-implantitis treatments, in relation to implant surfaces and abutment types.

Methods: Data from the National Health Insurance Service, covering approximately 50 million individuals, were used. Implants and abutments were categorized by codes, including surfaces such as resorbable blasting media, sandblasted large grit and acid-etched (SA) and hydroxyapatite coating, along with abutment structures (one-piece straight, two-piece straight, angled).

View Article and Find Full Text PDF

Purpose: To evaluate the wear resistance of a printed interim resin manufactured with different printing and postpolymerization parameters.

Materials And Methods: Overall, 130 rectangular resin specimens (15 × 10 × 10 mm) were 3D-printed. Among the specimens, 60 were printed with different printing orientations (0, 45, and 90 degrees) and layer thicknesses (50 and 100 μm) to create six groups to investigate the effects of the printing parameters (n = 10 per group).

View Article and Find Full Text PDF

Objectives: Evidence on the reliability of digital techniques for wear volume assessment using three-dimensional (3D) scan datasets is scarce. This study evaluated the reliability of a repeated-scan superimposition technique and two single-scan techniques in assessing wear volume loss on flat surfaces of 3D-printed resin specimens.

Methods: Cuboid-shaped (15×10×10 mm) resin specimens were 3D-printed (n = 14) and scanned before and after 200,000 cycles of masticatory simulation.

View Article and Find Full Text PDF

Objectives: Both resin-modified glass ionomer cement (RMGIC) and self-adhesive resin cement (SAC) may be suitable for cementation of full-coverage zirconia restorations. This retrospective study aimed to investigate the clinical outcomes of zirconia-based restorations cemented with RMGIC and compare them with those cemented with SAC.

Methods: Cases of full-coverage zirconia-based restorations cemented with either RMGIC or SAC between March 2016 and February 2019 were evaluated in this study.

View Article and Find Full Text PDF

Current restorative methods of restoring worn or eroded dentition present drawbacks that may deter dentists or patients from pursuing complete mouth rehabilitation. A novel additive manufacturing approach using 3D printed definitive composite resin restorations is described as a less technique-sensitive and more cost-effective alternative. These restorations are straightforward to repair, modify, or replace.

View Article and Find Full Text PDF

Purpose Completely edentulous arches can be restored using various prosthetic modalities, and the treatment outcome may include masticatory and speech discomforts. This study aimed to investigate the current status of prosthetic restoration modalities used for completely edentulous patients and investigate the association between prosthetic restoration modalities and subjective discomfort in mastication and speech by analyzing nationwide big data.Methods Of 97,622 individuals, data from 1,576 adults aged ≥40 years with no natural teeth and no requirement for 
additional prosthetic treatments were included.

View Article and Find Full Text PDF

Statement Of Problem: Three-dimensionally (3D)-printed composite resins have been marketed as materials for definitive restorations. However, limited information is available regarding the stability of the adhesive interface and the efficiency of 3D printed composite resins.

Purpose: The purpose of this in vitro study was to evaluate the integrity of the marginal adhesive interface before and after thermal and mechanical fatigue of an initial formulation of a 3D printed composite resin and to evaluate the efficiency of this manufacturing method.

View Article and Find Full Text PDF

Statement Of Problem: Interim restorations are often used along with mouth rinses during the healing period following surgical procedures. However, evidence regarding the color and surface properties of digitally fabricated interim restorations after oral rinsing is lacking.

Purpose: The purpose of this in vitro study was to evaluate whether different mouth rinses could affect the color and surface roughness of milled and printed interim restorations after simulated oral rinsing.

View Article and Find Full Text PDF

Purpose: To evaluate the effect of light-curing exposure time and location on polymerization of a restorative bulk-fill resin composite to lute endocrowns.

Methods: A light-cured restorative bulk-fill resin composite (Filtek One Bulk Fill) was submitted to direct light-curing by a high-power LED light-curing unit for 20 seconds as the positive control group (n= 10). Five more groups (n= 10) were light-cured in a natural tooth mold from two sites (labial and lingual) through a nanohybrid resin composite CAD-CAM restoration (Lava Ultimate A2 LT), for different irradiation times: 90 seconds per site, 40 seconds per site, 30 seconds per site, 20 seconds per site and 10 seconds per site.

View Article and Find Full Text PDF

Analysis of marginal adaptation of dental adhesive interfaces using scanning electron microscopy has proven to be a powerful nondestructive method to evaluate the quality of adhesion. This methodology is, however, time-consuming and needs expensive equipment. The purpose of this study was to evaluate the possibility and efficiency of using a digital optical microscope (DOM) to perform marginal analysis and to compare it with the scanning electron microscope (SEM) analysis.

View Article and Find Full Text PDF

: The aim of this study was to evaluate the effect of different enamel surface treatments on the micro-shear bond strength. : Sixty-four approximal surfaces from freshly extracted molars were randomly assigned to eight groups, according to combinations of the following enamel surface treatments: ground or unground, 37.5% phosphoric acid etching time of 15 or 30 s, and with or without primer application.

View Article and Find Full Text PDF

Objectives: To compare gloss retention of four different resin composites with their corresponding CAD/CAM composite blocks.

Materials And Methods: Four direct resin composites (Filtek Supreme XTE A2 Body (3M, USA), Tetric EvoCeram A2 (Ivoclar Vivadent, Liechtenstein), GrandioSO x-tra A2 (VOCO, Germany), G-aenial Universal A2 (GC, Japan)), and their corresponding CAD/CAM composite blocks were tested. A total of 288 samples were prepared and three different tests were performed: brushing, exposition to acidic fluoride gel and exposition to alcoholic solution.

View Article and Find Full Text PDF

Purpose To explore fracture strength and failure behaviour of minimally invasive CAD-CAM composite resin overlay restorations.Methods Eighty bi- and tri-layer cylindrical overlay model including the restoration bonded over bovine tooth dentin (Groups D) and enamel-dentin (Groups E) were assembled (diameter 9 mm). Restorations were milled from CAD-CAM composite resin blocks (Brilliant Crios, Coltène/Whaledent AG) in different thicknesses (0.

View Article and Find Full Text PDF

Purpose: To evaluate the minimal irradiation time to reach a sufficient polymerization of a photopolymerizable restorative bulk-fill resin composite to lute endocrowns.

Methods: A photopolymerizable restorative bulk-fill resin composite (Filtek One Bulk Fill) was submitted to direct light-curing by a high power LED light-curing unit for 20 seconds as the positive control group (n = 10). Five more test groups (n= 10) were light-cured in a natural tooth mold from three sites (buccal, palatal and occlusal) under a 9.

View Article and Find Full Text PDF

The purpose of this in-vitro study was to evaluate the fracture resistance and failure mode of non-invasively reinforced endodontically treated mandibular molars. Sixty freshly extracted defect-free mandibular molars were divided into four experimental groups with extensive MOD cavities on endodontically treated teeth with different restoration types and one control group with intact teeth (n  = 12). The groups were as follows: "Normal": direct resin composite; "Ring": glass fiber-reinforced strip (Dentapreg) wrapped around buccal and lingual walls followed by direct resin composite; "Inlay": indirect CAD/CAM resin composite inlay; "Onlay": indirect CAD/CAM resin composite onlay; "Intact": Intact teeth (Control).

View Article and Find Full Text PDF

Purpose: To compare the gloss retention of four resin based materials, two direct resin composites (Tetric EvoCeram and Filtek Supreme) and two indirect resin composite CAD-CAM blocks (Tetric CAD and Lava Ultimate).

Methods: 36 samples of 1 mm thickness were readied of each test material and manually polished with polishing discs (Sof-Lex) up to the finest grit size. Three gloss measurements per sample were taken (one every 120 degrees of sample rotation) by means of a glossmeter (Novo-Curve) for a total of 60 values obtained per tested material.

View Article and Find Full Text PDF

Extraoral facial scanning using a mobile phone has emerged as a viable, cost-effective option for certain applications not requiring high precision, such as patient education and 3-dimensional (3D) digital smile design. This technological development is particularly promising for general practitioners (GPs) who may not be able to invest in expensive,complex digital impressioning devices. This article describes and illustrates a relatively simple and accessible workflow that avails digital 3D facial scanning benefits to GPs.

View Article and Find Full Text PDF

In the original publication of the article, the author's name "Prof. René Daher" was inadvertently missed in the author group. This has been updated in this erratum.

View Article and Find Full Text PDF

The goals of the present study were to evaluate, in vitro, the staining of different composite resins submitted to different common beverages, and to compare the staining effect of each of these solutions. A total of 288 specimens were randomly divided into six groups and immersed for 4 weeks in five staining solutions represented by red wine, orange juice, coke, tea and coffee or in artificial saliva as a control group. When analyzed over a black background, mean ΔE00 values varied from 0.

View Article and Find Full Text PDF

The goal of this short communication is to present finite element analysis comparison of the stress distribution between CAD/CAM full crowns made of Lava Ultimate and of IPS e.max CAD, adhesively luted to natural teeth and to implant abutments with the shape of natural teeth. Six 3D models were prepared using a 3D content-creating software, based on a micro-CT scan of a human mandibular molar.

View Article and Find Full Text PDF

Objectives: To evaluate the biomechanical influence of reconnecting the buccal and lingual walls of endodontically treated lower molar with a large MOD cavity.

Methods: 3D models were created from a micro-CT scan of an extracted intact lower human molar. Finite element analysis was then used to compare the stress distribution and displacement of the structures between different models: Unrestored MOD on ETT (Unrest), MOD on ETT restored with composite resin (Norm), MOD on ETT reinforced with a non-invasive ring (Ring) and intact tooth as the control (Int).

View Article and Find Full Text PDF