The first aim of this work is the definition and the study of a suitable sampling method for the measurement of landfill gas (LFG) emissions from landfill surfaces, since, up to now, there are no codified nor universally accepted sampling methods for this specific task. The studied sampling method is based on the use of a static hood. The research work involves a preliminary theoretical study for the hood design, experimental tests for the definition of the optimal sampling procedures, and simulations of the hood fluid-dynamics for the system validation.
View Article and Find Full Text PDFScientificWorldJournal
November 2015
The ammonia loss through Nalophan bags has been studied. The losses observed for storage conditions and times as allowed by the reference standard for dynamic olfactometry (EN 13725:2003) indicate that odour concentration values due to the presence of small molecules may be significantly underestimated if samples are not analysed immediately after sampling. A diffusion model was used in order to study diffusion through the bag.
View Article and Find Full Text PDFElectronic nose applications in environmental monitoring are nowadays of great interest, because of the instruments' proven capability of recognizing and discriminating between a variety of different gases and odors using just a small number of sensors. Such applications in the environmental field include analysis of parameters relating to environmental quality, process control, and verification of efficiency of odor control systems. This article reviews the findings of recent scientific studies in this field, with particular focus on the abovementioned applications.
View Article and Find Full Text PDFThe aim of the work is to verify the diffusion rate of ammonia through the Nalophan™ film that constitutes the sampling bag, considering storage times ranging from 1 to 26 h. The ammonia decay over time was evaluated using gas-chromatography for the quantification of ammonia concentration inside the bag. The research assesses the roles of both of ammonia and water concentration gradients at the polymeric film interface on the diffusion process.
View Article and Find Full Text PDFThis paper focuses on the opportunities for using electronic noses for odour exposure assessment purposes, especially in cases where dispersion modelling is not applicable. Such cases include, for instance, those sources where a detailed characterisation and quantification of the odour emissions for every hour of the simulation time domain is particularly difficult, due to the nature of the source or to the variability of the emissions over time. In such situations, it is useful to determine odour exposure directly at receptors instead.
View Article and Find Full Text PDFSampling is one of the main issues pertaining to odor characterization and measurement. The aim of sampling is to obtain representative information on the typical characteristics of an odor source by means of the collection of a suitable volume fraction of the effluent. The most important information about an emission source for odor impact assessment is the so-called Odor Emission Rate (OER), which represents the quantity of odor emitted per unit of time, and is expressed in odor units per second (ou∙s-1).
View Article and Find Full Text PDFExhaustive odour impact assessment should involve the evaluation of the impact of odours directly on citizens. For this purpose it might be useful to have an instrument capable of continuously monitoring ambient air quality, detecting the presence of odours and also recognizing their provenance. This paper discusses the laboratory and field tests conducted in order to evaluate the performance of a new electronic nose, specifically developed for monitoring environmental odours.
View Article and Find Full Text PDFThe title compound, C(21)H(29)ClO(3) [systematic name (8R,9S,10R,13S,14S,17S)-4-chloro-3-oxoandrost-4-en-17β-yl acetate], is a 4-chloro derivative of testosterone, used as an anabolic androgenic agent or applied topically in ophthalmological and dermatological treatments. The absolute configurations at positions 8, 9, 10, 13, 14 and 17 were established by refinement of the Flack parameter as R, S, R, S, S, and S, respectively. Rings B and C of the steroid ring system adopt chair conformations, ring A has a half-chair conformation, while ring D is in a C(13) envelope conformation.
View Article and Find Full Text PDFSince several years odour nuisance is a serious environmental concern in the city of Terni, whose citizens are repeatedly lamenting the presence of malodours. This paper describes the olfactometric approach adopted for assessing the odour impact on the city of Terni, caused by the co-presence of three important industrial poles: the steel industry pole, the chemical pole and a third industrial pole, comprising different activities for the treatment of wastewaters and solid waste. The combination of analyses by dynamic olfactometry and dispersion modelling allowed the evaluation of the citizens' exposure to the industrial odours, resulting in both the quantification of emissions and the assessment of their impact on the territory.
View Article and Find Full Text PDFIn this study, the results of odour concentration measurements on different wastewater treatment plants are presented and used in order to estimate the odour emission factors relevant to single odour sources. An odour emission factor is a representative value that relates the quantity of odour released to the atmosphere to a specific activity index, which in this case was the plant treatment capacity, resulting in an odour emission factor expressed in odour units per cubic metre of treated sewage. The results show that the major odour source of a wastewater treatment plant is represented by the primary sedimentation (with an OEF equal to 1.
View Article and Find Full Text PDFThe odour impact of a composting plant situated in an urbanized area was evaluated by continuously monitoring the ambient air close to the plant during a period of about 4 days using two electronic noses. One electronic nose was installed in a nearby house, and the other one inside the perimeter of the composting plant in order to compare the response of both instruments. The results of the monitoring are represented by tables that report the olfactory class and the odour concentration value attributed to the analyzed air for each of the 370 measurements carried out during the monitoring period.
View Article and Find Full Text PDF