Objectives: This study evaluated the mechanical, optical, microstructural, surface, and adhesive behavior of a 3D printing resin comparing it with a machinable resin composite.
Materials And Methods: Specimens of different sizes and shapes were either printed (Vitality, Smart Dent) or machinable (Grandio Blocs, Voco GmbH) resin composites with similar composition were prepared. Surface and mechanical characterization were performed with Knoop hardness, flexural strength (three-point-bending), and elastic modulus tests.
The purpose of this study was to evaluate the fatigue survival of 5Y-PSZ zirconia infiltrated with an experimental glass and bonded onto dentin analogues. Disc-shaped specimens of a 5Y-PSZ (Katana UTML Kuraray Noritake) were cemented onto dentin analogs (NEMA G10) and divided into four groups (n = 15): Zctrl Group (control, without infiltration); Zglz Group (Glaze, compression surface); Zinf-comp Group (Experimental Glass, compression surface); Zinf-tens Group (Experimental Glass, tension surface). Surface treatments were varied.
View Article and Find Full Text PDFObjective: This study evaluated the effect of an experimental borosilicate glass on the mechanical and optical behavior of 5Y-PSZ zirconia and comparing it to commercial glaze and as-sintered.
Methods: Disc-shaped specimens of a 5Y-PSZ (Zpex Smile) were prepared and sintered (1550 °C, 2 h). The zirconia discs were randomly divided according to the surface treatment: as-sintered (C), commercial glaze (G), and experimental borosilicate glass (SL).
Purpose: This study evaluated the fatigue failure load (FFL) and the number of cycles for fatigue failure (CFF) of traditional (porcelain layer up) and reversed (zirconia layer up) designs of porcelain-veneered zirconia samples prepared with heat-pressing or file-splitting techniques.
Materials And Methods: Zirconia discs were prepared and veneered with heat-pressed or machined feldspathic ceramic. The bilayer discs were bonded onto a dentin-analog according to the bilayer technique and sample design: traditional heat-pressing (T-HP), reversed heat-pressing (R-HP), traditional file-splitting with fusion ceramic (T-FC), reversed file-splitting with fusion ceramic R-FC), traditional file-splitting with resin cement (T-RC), and reversed file-splitting with resin cement (R-RC).
Objectives: To evaluate the effect of the remaining tooth structure and different CAD/CAM materials on the fatigue performance and failure mode of endodontically treated premolars restored with endocrowns.
Materials And Methods: Ninety maxillary premolars were endodontically treated and assigned into 6 groups (n = 15) according to the number of remaining axial walls (four, three, and two) and restorative materials (ultra-translucent zirconia 5Y-PSZ [KATANA UTML] and lithium disilicate [IPS e.max-CAD]).
Clin Oral Investig
February 2023
Objectives: Photo- and dual-polymerized resin-based luting agent was evaluated for elastic moduli effects on ultra-thin lithium disilicate (LD) glass-ceramic strengthening, structural reliability, and stress distribution.
Materials And Methods: One hundred-sixty LD discs (IPS e.max CAD, Ivoclar/Vivadent) were produced in ultra-thin thicknesses (half with 0.
Objectives: This study was performed to evaluate fatigue survival by shear test in the union of leucite-reinforced feldspathic ceramic using different cement thicknesses.
Materials And Methods: Leucite-reinforced glass ceramics blocks were sectioned in 2-mm thick slices where resin cylinders were cemented. The samples were distributed in two experimental groups ( = 20) according to the cement thickness (60 and 300 μm).
Purpose: This study sought to investigate the acceptance rate and associated factors of COVID-19 vaccines among dentists and dental students in seven countries.
Material And Methods: A structured questionnaire prepared and guided by the report of the SAGE Working Group on Vaccine Hesitancy was distributed among groups of dentists and dental students in seven countries across four continents.
Results: A total of 1527 subjects (850 dentists and 677 dental students) participated in this survey.
Int J Prosthodont
September 2022
Purpose: To evaluate the biaxial flexural strength of different porcelain-to-zirconia thickness ratios and bonding strategies of a stress-free bilayer CAD/CAM ceramic system.
Materials And Methods: A total of 60 zirconia discs (diameter: 15 mm; thickness: 0.3 or 0.
J Adhes Dent
August 2022
Purpose: To evaluate the effect of two surface conditioning methods, namely conventional hydrofluoric acid vs self-etching primer, and the application of adhesive on the bond strength of resin cement to CAD/CAM glass-ceramics.
Materials And Methods: Blocks (N = 96) (12 x 10 x 2.5 mm) were manufactured, 24 for each tested ceramic type: lithium silicate ceramic (LS), polymer-infiltrated ceramic (PIC), leucite-reinforced feldspathic ceramic (FD), and lithium-disilicate glass-ceramic (LD).
Dental interfaces are subject to mixed-mode loading. This study provides practical guidance for determining interfacial fracture toughness of dental ceramic systems. We address interfacial fracture of a composite resin cement sandwiched between two dental ceramic materials.
View Article and Find Full Text PDFObjective: The aim of this study was to evaluate the effect of four different finishing procedures on the fatigue strength of a fully stabilized zirconia (5Y-FSZ) material.
Materials And Methods: Disc-shaped specimens of a 5Y-FSZ (Katana UTML, Kuraray Noritake) were made (ISO 6872-2015), grinded with 600- and 1200-grit silicon carbide paper, sintered as recommended, and randomly assigned into four groups according to the finishing technique: C (control, as-sintered), P (polished with polishing rubbers), G (glaze application - powder/liquid technique), and PG (polished with polishing rubbers + glaze application - powder/liquid). Then fatigue strength (staircase method), X-ray diffraction (XRD), and scanning electron microscopy (SEM) analyses were performed.
Objectives: Even though several effective vaccines are available to combat the COVID-19 pandemic, wide disparities in vaccine distribution, and vaccine acceptance rates between high- and low-income countries appear to be major threats toward achieving population immunity. Our global descriptive study aims to inform policymakers on factors affecting COVID-19 vaccine acceptance among healthcare workers (HCWs) in 12 countries, based on income index. We also looked for possible predictors of vaccine acceptance among the study sample.
View Article and Find Full Text PDFJ Adv Prosthodont
December 2021
Purpose: To characterize the microstructure of three yttria partially stabilized zirconia ceramics and to compare their hardness, indentation fracture resistance (IFR), biaxial flexural strength (BFS), and fatigue flexural strength.
Materials And Methods: Disc-shaped specimens were obtained from 3Y-TZP (Vita YZ HT), 4Y-PSZ (Vita YZ ST) and 5Y-PSZ (Vita YZ XT), following the ISO 6872/2015 guidelines for BFS testing (final dimensions of 12 mm in diameter, 0.7 and 1.
J Clin Exp Dent
November 2021
Background: The objective of this in vitro study was to evaluate the effect of the active application of self-etching ceramic primer (ME&P) on the bond strength of different dental CAD/CAM materials (Lithium Disilicate ceramic (LD), Leucite ceramic (LE), Zirconia reinforced lithium silicate ceramic (ZLS), and Hybrid ceramic (HC)) with thermocycling aging.
Material And Methods: The samples were randomly divided into 16 groups (n = 20). Dual resin cement cylinders were made and light cured for 10 s (1.
Clin Oral Investig
January 2022
Objective: To investigate the influence of different finishing/polishing techniques and in situ aging on the flexural strength (σ), surface roughness, and Candida albicans adherence of 5 mol% yttria-stabilized zirconia (ultratranslucent zirconia).
Materials And Methods: A total of 120 zirconia bars (Prettau Anterior, Zirkonzahn) with dimensions of 8 × 2 × 0.5 mm were divided into 8 groups (n = 15) according to two factors: "in situ aging" (non-aged and aged (A)) and "finishing/polishing" (control (C), diamond rubber polishing (R), coarse grit diamond bur abrasion (B), and coarse grit diamond bur abrasion + diamond rubber polishing (BR)).
The loss of dental structure caused by endodontic treatment is responsible for a decrease in tooth resistance, which increases susceptibility to fracture. Therefore, it is important that minimally invasive treatments be performed to preserve the dental structure and increase the resistance to fracture of endodontically treated posterior teeth. To evaluate under axial loads, using the finite element method, the stress distribution in endodontically treated molars restored with both transfixed or vertical glass fiber posts (GFP) and resin composite.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
September 2021
The aim of this study was to evaluate the effect of in-lab simulation procedures performed on a lithium disilicate ceramic luted to a dentin-analogue material regarding the fatigue performance and topographic changes. Lithium disilicate ceramic (IPS e.max CAD) discs (Ø = 13.
View Article and Find Full Text PDFInt J Periodontics Restorative Dent
February 2021
The purpose of this study was to evaluate the cleaning and surface treatment techniques in the repair of aged and contaminated yttrium oxide-stabilized tetragonal polycrystalline zirconia (Y-TZP). From a total of 80 specimens of Y-TZP, 60 were subjected to aging simulation in a buccal environment with degradation in an autoclave for 24 hours (127°C/1.5 bar) and contaminated with Streptococcus mutans.
View Article and Find Full Text PDFBackground: To evaluate, , the effects of the cooling protocol, application technique, and veneering ceramic thickness on the fracture resistance of ceramic crowns with Y-TZP frameworks.
Material And Methods: 80 frameworks were made from zirconia by the CAD/CAM technique and divided into 8 groups (n = 10) according to the factors: "application technique" (stratified-L and pressed -P), "thickness" (1 mm and 2 mm), and "cooling protocol" (slow-S and fast-F) of the feldspathic veneering ceramic. After, all crowns were cemented over G10 preparations with resin cement (Panavia F, Kuraray), mechanically cycled (2x106 cycles, 200 N, 3Hz), and subjected to the axial compression resistance test (0.
This study evaluated the influence of occlusal resin cement space on the fatigue performance of bonded-leucite crowns to a dentin-analogue material. Leucite anatomical crowns were adhesively cemented to dentin-like preparations having distinct occlusal cement space (50, 100 and 300 μm) (n = 18), and subjected to step-stress fatigue testing (150 N - 350 N; step-size: 25 N; 20,000 cycles/step; 20 Hz). Fatigue data (load and number of cycles for failure) were analyzed using Kaplan-Meier and Mantel-Cox (log-rank) tests (p <0.
View Article and Find Full Text PDFThe aim of this study was to evaluate the effects of different concentrations of hydrofluoric acid (HF) and etching times on the flexural strength, roughness, wettability, and type of failure of a hybrid ceramic (VITA ENAMIC). Blocks of the ceramic material were made according to the norms of International Organization for Standardization standard 6872:2015 and randomly divided into 7 groups (n = 13): control (no treatment); surface etching with 5% HF for 30 (HF5-30), 60 (HF5-60), or 90 (HF5-90) seconds; and surface etching with 10% HF for 30 (HF10-30), 60 (HF10-60), or 90 (HF10-90) seconds. The adhesive surface of 10 specimens in each group was cemented with dual-curing resin cement.
View Article and Find Full Text PDFBackground: Endocrown restorations as a conservative approach to restore endodontically treated teeth still need investigation under fatigue and made in different materials. This study evaluated the effect of restorative material and restoration thickness on the maximum fracture load of endocrowns subjected to cyclic loading.
Material And Methods: Sixty (60) third molar teeth received an endocrown preparation with three different heights of remaining dental tissue (1.
J Mech Behav Biomed Mater
February 2020
This study aimed to evaluate the effects of low temperature degradation (LTD) on commercial dental zirconias (conventional and high-translucent - HT) with different microstructures, as well as on their mechanical properties and t-m phase transformation. The amount of monoclinic zirconia in different depths was quantified using X-ray diffraction (XRD) with different anode tubes (Cr, Co and Cu). XRD was also used to measure the residual stress of the materials at 0 h, 26 h and 140 h aging times.
View Article and Find Full Text PDF