In 2014-2015, the Luxembourg Red Cross (LRC) implemented a fully automated system (FAS) able to process 4 whole blood units simultaneously, and a pathogen reduction technology (PRT) based on riboflavin and ultraviolet light to improve safety of platelet concentrates (PCs). In this observational study, the impact of both technologies to enable this centralised blood transfusion centre to provide safe and timely blood components supply for the whole country was analysed. Standard quality control parameters for blood components, productivity and safety were compared from data collected with the conventional semi- automated buffy coat method and with FAS/PRT.