Introduction: Adult patients who have suffered acute cardiac or pulmonary failure are increasingly being treated using extracorporeal membrane oxygenation (ECMO), a cardiopulmonary bypass technique. While ECMO has improved the long-term outcomes of these patients, neurological injuries can occur from underlying illness or ECMO itself. Cerebral autoregulation (CA) allows the brain to maintain steady perfusion during changes in systemic blood pressure.
View Article and Find Full Text PDFExtracorporeal membrane oxygenation (ECMO) is a form of temporary cardiopulmonary bypass for patients with acute respiratory or cardiac failure refractory to conventional therapy. Its usage has become increasingly widespread and while reported survival after ECMO has increased in the past 25 years, the incidence of neurological injury has not declined, leading to the pressing question of how to improve time-to-detection and diagnosis of neurological injury. The neurological status of patients on ECMO is clinically difficult to evaluate due to multiple factors including illness, sedation, and pharmacological paralysis.
View Article and Find Full Text PDFPurpose: The neurologic examination of patients undergoing extracorporeal membrane oxygenation (ECMO) is crucial for evaluating irreversible encephalopathy but is often obscured by sedation or neuromuscular blockade. Noninvasive neuromonitoring modalities including diffuse correlation spectroscopy and EEG measure cerebral perfusion and neuronal function, respectively. We hypothesized that encephalopathic ECMO patients with greater degree of irreversible cerebral injury demonstrate less correlation between electrographic activity and cerebral perfusion than those whose encephalopathy is attributable to medications.
View Article and Find Full Text PDFA design for a low-cost, heterodyne, frequency domain-diffuse optical spectroscopy system is presented and validated. The system uses a single wavelength of 785 nm and a single detector to illustrate the capability, but is built in a modular fashion to make it easily expandable to additional wavelengths and detectors. The design incorporates methods to allow software-based control over the system operating frequency, laser diode output amplitude, and detector gain.
View Article and Find Full Text PDFA feature issue is being presented by a team of guest editors containing papers based on studies presented at the Optica Biophotonics Congress: Biomedical Optics held on April 24-27, 2022 in Fort Lauderdale, Florida, USA.
View Article and Find Full Text PDFA co-registered speckle contrast optical tomography and frequency domain-diffuse optical tomography system has been designed for imaging total hemoglobin concentration, blood oxygenation, and blood flow with the future aim of monitoring Jones fractures of the fifth metatarsal. Experimental validation was performed using both tissue-mimicking phantoms and cuff occlusion experiments. Results of these tissue phantom experiments ensure accurate recovery of three-dimensional distributions of optical properties and flow.
View Article and Find Full Text PDFPeripheral veno-arterial extracorporeal membrane oxygenation (ECMO) artificially oxygenates and circulates blood retrograde from the femoral artery, potentially exposing the brain to asymmetric perfusion. Though ECMO patients frequently experience brain injury, neurologic exams and imaging are difficult to obtain. Diffuse correlation spectroscopy (DCS) non-invasively measures relative cerebral blood flow (rBF) at the bedside using an optical probe on each side of the forehead.
View Article and Find Full Text PDFWhen dealing with longitudinal data, linear mixed-effects models (LMMs) are often used by researchers. However, LMMs are not always the most adequate models, especially if we expect a nonlinear relationship between the outcome and a continuous covariate. To allow for more flexibility, we propose the use of a semiparametric mixed-effects model to evaluate the overall treatment effect on the hemodynamic responses during bone graft healing and build a prediction model for the healing process.
View Article and Find Full Text PDFDespite widespread use of conventional diagnostic methods in orthopaedic applications, limitations still exist in detection and diagnosing many pathologies especially at early stages when intervention is most critical. The use of biomaterials to develop diagnostics and theranostics, including nanoparticles and scaffolds for systemic or local applications, has significant promise to address these shortcomings and enable successful clinical translation. These developments in both modular and holistic design of diagnostic and theranostic biomaterials may improve patient treatments for myriad orthopaedic applications ranging from cancer to fractures to infection.
View Article and Find Full Text PDFThe guest editors introduce a feature issue containing papers based on research presented at the OSA Biophotonics Congress (the former BIOMED) 20-23 April 2020, in the first all virtual, web conference format undertaken by OSA.
View Article and Find Full Text PDFAllograft is the current gold standard for treating critical-sized bone defects. However, allograft healing is usually compromised partially due to poor host-mediated vascularization. In the efforts towards developing new methods to enhance allograft healing, a non-terminal technique for monitoring the vascularization is needed in pre-clinical mouse models.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2020
Localized muscle fatigue (LMF) decreases muscular strength, while affects the performance and potentially increases the risk of musculoskeletal disorders (MSD). An important mechanism in recovering from muscle fatigue is blood flow (BF). The BF response to muscle contraction and fatigue is highly dynamic and difficult to predict, as it depends on both metabolic demand and intramuscular pressure.
View Article and Find Full Text PDFNoninvasive monitoring of vascularization can potentially diagnose impaired bone healing earlier than current radiographic methods. In this study, a noncontact diffuse correlation tomography (DCT) technique was employed to measure longitudinal blood flow changes during bone healing in a murine femoral fracture model. The three-dimensional distribution of the relative blood flow was quantified from one day pre-fracture to 48 days post-fracture.
View Article and Find Full Text PDFMuch attention has focused recently on utilizing components of the extracellular matrix (ECM) as natural building blocks for a variety of tissue engineering applications and regenerative medicine therapies. Consequently, new fabrication methods are being sought to enable molecular control over the structural characteristics of ECM molecules in order to improve their biological function. Exposing soluble collagen to acoustic forces associated with ultrasound propagation produces localized variations in collagen microfiber organization that in turn, promote cell behaviors essential for tissue regeneration, including cell migration and matrix remodeling.
View Article and Find Full Text PDFThis guest editorial introduces the special section on Translational Biophotonics.
View Article and Find Full Text PDFBlood flow changes during bone graft healing have the potential to provide important information about graft success, as the nutrients, oxygen, circulating cells and growth factors essential for integration are delivered by blood. However, longitudinal monitoring of blood flow changes during graft healing has been a challenge due to limitations in current techniques. To this end, non-invasive diffuse correlation tomography (DCT) was investigated to enable longitudinal monitoring of three-dimensional blood flow changes in deep tissue.
View Article and Find Full Text PDFNicotinamide has been shown to affect blood flow in both tumor and normal tissues, including skeletal muscle. Intraperitoneal injection of nicotinamide was used as a simple intervention to test the sensitivity of noninvasive diffuse correlation spectroscopy (DCS) to changes in blood flow in the murine left quadriceps femoris skeletal muscle. DCS was then compared with the gold-standard fluorescent microsphere (FM) technique for validation.
View Article and Find Full Text PDFThe longitudinal effect of an anti-vascular endothelial growth factor receptor 2 (VEGFR-2) antibody (DC 101) therapy on a xenografted renal cell carcinoma (RCC) mouse model was monitored using hybrid diffuse optics. Two groups of immunosuppressed male nude mice (seven treated, seven controls) were measured. Tumor microvascular blood flow, total hemoglobin concentration and blood oxygenation were investigated as potential biomarkers for the monitoring of the therapy effect twice a week and were related to the final treatment outcome.
View Article and Find Full Text PDFThe non-invasive, measurement of microvascular blood flow has the potential to enhance breast cancer therapy monitoring. Here, longitudinal blood flow of 4T1 murine breast cancer (N=125) under chemotherapy was quantified with diffuse correlation spectroscopy based on layer models. Six different treatment regimens involving doxorubicin, cyclophosphamide, and paclitaxel at clinically relevant doses were investigated.
View Article and Find Full Text PDFLongitudinal blood flow during murine bone graft healing was monitored non-invasively using diffuse correlation tomography. The system utilized spatially dense data from a scanning set-up, non-linear reconstruction, and micro-CT anatomical information. Weekly measurements were performed.
View Article and Find Full Text PDFVascular infiltration and associated alterations in microvascular blood flow are critical for complete bone graft healing. Therefore, real-time, longitudinal measurement of blood flow has the potential to successfully predict graft healing outcomes. Herein, we non-invasively measure longitudinal blood flow changes in bone autografts and allografts using diffuse correlation spectroscopy in a murine femoral segmental defect model.
View Article and Find Full Text PDFA non-contact galvanometer-based optical scanning system for diffuse correlation tomography was developed for monitoring bone graft healing in a murine femur model. A linear image reconstruction algorithm for diffuse correlation tomography was tested using finite-element method based simulated data and experimental data from a femur or a tube suspended in a homogeneous liquid phantom. Finally, the non-contact system was utilized to monitor in vivo blood flow changes prior to and one week after bone graft transplantation within murine femurs.
View Article and Find Full Text PDFIntroduction: Non-invasive diffuse optical tomography (DOT) and diffuse correlation spectroscopy (DCS) can detect and characterize breast cancer and predict tumor responses to neoadjuvant chemotherapy, even in patients with radiographically dense breasts. However, the relationship between measured optical parameters and pathological biomarker information needs to be further studied to connect information from optics to traditional clinical cancer biology. Thus we investigate how optically measured physiological parameters in malignant tumors such as oxy-, deoxy-hemoglobin concentration, tissue blood oxygenation, and metabolic rate of oxygen correlate with microscopic histopathological biomarkers from the same malignant tumors, e.
View Article and Find Full Text PDFMicrovascular blood flow contrast is an important hemodynamic and metabolic parameter with potential to enhance in vivo breast cancer detection and therapy monitoring. Here we report on non-invasive line-scan measurements of malignant breast tumors with a hand-held optical probe in the remission geometry. The probe employs diffuse correlation spectroscopy (DCS), a near-infrared optical method that quantifies deep tissue microvascular blood flow.
View Article and Find Full Text PDF