We report methods that improve the quantification of digital bead assays (DBA)─such as the digital enzyme-linked immunosorbent assay (ELISA)─that have found widespread use for high sensitivity measurement of proteins in clinical research and diagnostics. In digital ELISA, proteins are captured on beads, labeled with enzymes, individual beads are interrogated for activity from one or more enzymes, and the average number of enzymes per bead (AEB) is determined based on Poisson statistics. The widespread use of digital ELISA has revealed limitations to the original approaches to quantification that can lead to inaccurate AEB.
View Article and Find Full Text PDFDisease detection at the molecular level is driving the emerging revolution of early diagnosis and treatment. A challenge facing the field is that protein biomarkers for early diagnosis can be present in very low abundance. The lower limit of detection with conventional immunoassay technology is the upper femtomolar range (10(-13) M).
View Article and Find Full Text PDFWe have developed a method that enables the multiplexed detection of proteins based on counting single molecules. Paramagnetic beads were labeled with fluorescent dyes to create optically distinct subpopulations of beads, and antibodies to specific proteins were then immobilized to individual subpopulations. Mixtures of subpopulations of beads were then incubated with a sample, and specific proteins were captured on their specific beads; these proteins were then labeled with enzymes via immunocomplex formation.
View Article and Find Full Text PDFWe report a method for isolating individual paramagnetic beads in arrays of femtolitre-sized wells and detecting single enzyme-labeled proteins on these beads using sequential fluid flows in microfabricated polymer array assemblies. Arrays of femtolitre-sized wells were fabricated in cyclic olefin polymer (COP) using injection moulding based on DVD manufacturing. These arrays were bonded to a complementary fluidic structure that was also moulded in COP to create an enclosed device to allow delivery of liquids to the arrays.
View Article and Find Full Text PDFSingle molecule detection of target molecules specifically bound by paired fluorescently labeled probes has shown great potential for sensitive quantitation of biomolecules. To date, no reports have rigorously evaluated the analytical capabilities of a single molecule detection platform employing this dual-probe approach or the performance of its data analysis methodology. In this paper, we describe a rapid, automated, and sensitive multicolor single molecule detection apparatus and a novel extension of coincident event counting based on detection of fluorescent probes.
View Article and Find Full Text PDF