Publications by authors named "Ravikumar Boosi"

A rapid, sensitive and accurate liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of miglitol (CAS 72432-03-2), an alpha-glucosidase inhibitor, in human plasma using gabapentin (CAS 60142-96-3) as internal standard (IS). Following protein precipitation, the analytes were separated using an isocratic mobile phase on a reversed phase phenyl column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 208/146 for miglitol and m/z 172/154 for the IS. The assay exhibited a linear dynamic range of 100-6000 ng/mL for miglitol in human plasma.

View Article and Find Full Text PDF

A simple, sensitive and rapid high-performance liquid chromatography/positive electrospray ionization tandem mass spectrometry method was developed and validated for the assay of clopidogrel in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective [M+H](+) ions, m/z 322/212 for clopidogrel and m/z 264/154 for the internal standard. The assay exhibited a linear dynamic range of 5-6000 pg/mL for clopidogrel in human plasma.

View Article and Find Full Text PDF

A simple, sensitive and rapid liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method was developed and validated for the quantification of olanzapine, atypical antipsychotic drug, in human plasma using loratadine as internal standard (IS). Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse phase C18 column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 313/256 for olanzapine and m/z 383/337 for the IS. The assay exhibited a linear dynamic range of 0.

View Article and Find Full Text PDF

A simple, sensitive, selective and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of atorvastatin and its active metabolites ortho-hydroxyatorvastatin and para-hydroxyatorvastatin in human plasma using rosuvastatin as internal standard (IS). Following simple liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 559/440 for atorvastatin, m/z 575/466 for ortho-hydroxyatorvastatin, m/z 575/440 for para-hydroxyatorvastatin and m/z 482/258 for the IS. The assay exhibited a linear dynamic range of 0.

View Article and Find Full Text PDF

A simple, sensitive and rapid high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the assay of granisetron in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 313/138 for granisetron and m/z 409/228 for the IS. The assay exhibited a linear dynamic range of 0.

View Article and Find Full Text PDF