Publications by authors named "Ratan Shah"

Introduction: DLBCL with gastrointestinal involvement is a relatively rare form of extra-nodal lymphoma, and complications such as spontaneous perforation and jejunal stricture in this disease are even rarer.

Case Presentation: A 45-year-old male presented with abdominal pain and vomiting. Diagnosis revealed a jejunal stricture with perforation, necessitating resection and anastomosis.

View Article and Find Full Text PDF

Rationale And Objectives: To assess the interaction between the availability of prior examinations and digital breast tomosynthesis (DBT) in decisions to recall a woman during interpretation of mammograms.

Materials And Methods: Eight radiologists independently interpreted twice 36 mammography examinations, each of which had current and prior full-field digital mammography images (FFDM) and DBT under a Health Insurance Portability and Accountability Act-compliant, institutional review board-approved protocol (written consent waived). During the first reading, three sequential ratings were provided using FFDM only, followed by FFDM + DBT, and then followed by FFDM + DBT + priors.

View Article and Find Full Text PDF

Objective: The purpose of this article is to compare the ability of digital breast tomosynthesis and full field digital mammography (FFDM) to detect and characterize calcifications.

Materials And Methods: One hundred paired examinations were performed utilizing FFDM and digital breast tomosynthesis. Twenty biopsy-proven cancers, 40 biopsy-proven benign calcifications, and 40 randomly selected negative screening studies were retrospectively reviewed by five radiologists in a crossed multireader multimodal observer performance study.

View Article and Find Full Text PDF

Rationale And Objectives: To investigate consistency of the orders of performance levels when interpreting mammograms under three different reading paradigms.

Materials And Methods: We performed a retrospective observer study in which nine experienced radiologists rated an enriched set of mammography examinations that they personally had read in the clinic ("individualized") mixed with a set that none of them had read in the clinic ("common set"). Examinations were interpreted under three different reading paradigms: binary using screening Breast Imaging Reporting and Data System (BI-RADS), receiver-operating characteristic (ROC), and free-response ROC (FROC).

View Article and Find Full Text PDF

The authors investigated radiologists, performances during retrospective interpretation of screening mammograms when using a binary decision whether to recall a woman for additional procedures or not and compared it with their receiver operating characteristic (ROC) type performance curves using a semi-continuous rating scale. Under an Institutional Review Board approved protocol nine experienced radiologists independently rated an enriched set of 155 examinations that they had not personally read in the clinic, mixed with other enriched sets of examinations that they had individually read in the clinic, using both a screening BI-RADS rating scale (recall/not recall) and a semi-continuous ROC type rating scale (0 to 100). The vertical distance, namely the difference in sensitivity levels at the same specificity levels, between the empirical ROC curve and the binary operating point were computed for each reader.

View Article and Find Full Text PDF

Purpose: To compare radiologists' performance during interpretation of screening mammograms in the clinic with their performance when reading the same mammograms in a retrospective laboratory study.

Materials And Methods: This study was conducted under an institutional review board-approved, HIPAA-compliant protocol; the need for informed consent was waived. Nine experienced radiologists rated an enriched set of mammograms that they had personally read in the clinic (the "reader-specific" set) mixed with an enriched "common" set of mammograms that none of the participants had previously read in the clinic by using a screening Breast Imaging Reporting and Data System (BI-RADS) rating scale.

View Article and Find Full Text PDF

Purpose: To retrospectively evaluate whether recall, biopsy, and positive biopsy rates for a group of radiologists who met requirements of Mammography Quality Standards Act of 1992 (MQSA) demonstrated any change over time during a 27-month period (nine consecutive calendar quarters).

Materials And Methods: Institutional review board approved study protocol, and informed consent was waived. All screening mammograms that had been interpreted by MQSA-qualified radiologists between January 1, 2001, and March 31, 2003, were reviewed.

View Article and Find Full Text PDF

Rationale And Objectives: The authors evaluated the impact of different computer-aided detection (CAD) cueing conditions on radiologists' performance levels in detecting and classifying masses depicted on mammograms.

Materials And Methods: In an observer performance study, eight radiologists interpreted 110 subtle cases six times under different display conditions to detect depicted masses and classify them as benign or malignant. Forty-five cases depicted biopsy-proven masses and 65 were negative.

View Article and Find Full Text PDF

Background: The authors investigated the correlation between recall and detection rates in a group of 10 radiologists who had read a high volume of screening mammograms in an academic institution.

Methods: Practice-related and outcome-related databases of verified cases were used to compute recall rates and tumor detection rates for a group of 10 Mammography Quality Standard Act (MQSA)-certified radiologists who interpreted a total of 98,668 screening mammograms during the years 2000, 2001, and 2002. The relation between recall and detection rates for these individuals was investigated using parametric Pearson (r) and nonparametric Spearman (rho) correlation coefficients.

View Article and Find Full Text PDF

Background: Computer-aided mammography is rapidly gaining clinical acceptance, but few data demonstrate its actual benefit in the clinical environment. We assessed changes in mammography recall and cancer detection rates after the introduction of a computer-aided detection system into a clinical radiology practice in an academic setting.

Methods: We used verified practice- and outcome-related databases to compute recall rates and cancer detection rates for 24 Mammography Quality Standards Act-certified academic radiologists in our practice who interpreted 115,571 screening mammograms with (n = 59,139) or without (n = 56,432) the use of a computer-aided detection system.

View Article and Find Full Text PDF

Objective: We assessed and compared the benefit of using images acquired 1 year or 2 years previously during mammography interpretations.

Materials And Methods: Eleven radiologists and one resident reviewed 128 cases three times: once without prior mammograms for comparison, once with mammograms from the most recent (1 year) examination, and once with mammograms acquired 2 years previously. They were asked to determine whether the patient should be recalled for additional procedures.

View Article and Find Full Text PDF

Rationale And Objectives: The authors assessed and compared the performance of a computer-aided detection (CAD) scheme for the detection of masses and microcalcification clusters on a set of images collected from two consecutive ("current" and "prior") mammographic examinations.

Materials And Methods: A previously developed CAD scheme was used to assess two consecutive screening mammograms from 200 cases in which the current mammogram showed a mass or cluster of microcalcifications that resulted in breast biopsy. The latest prior examinations had been initially interpreted as negative or definitely benign findings (Breast Imaging Reporting and Data System rating, 1 or 2).

View Article and Find Full Text PDF