Publications by authors named "Randy King"

The soft tissue thermal index defined in the Output Display Standard is not applicable to eye exposures because of unique eye properties such as high ultrasound absorption in the lens and orbital fat. To address this potential safety issue, the U.S.

View Article and Find Full Text PDF

Developments in the use of ultrasound to stimulate and modulate neural activity have raised the possibility of using ultrasound as a new investigative and therapeutic tool in brain research. Although the phenomenon of ultrasound-induced neurostimulation has a long history dating back many decades, until now there has been little evidence of a clearly localized effect in the brain, a necessary requirement for the technique to become genuinely useful. Here we report clearly distinguishable effects in sonicating rostral and caudal regions of the mouse motor cortex.

View Article and Find Full Text PDF

Ultrasound-induced neurostimulation has recently gained increasing attention, but little is known about the mechanisms by which it affects neural activity or about the range of acoustic parameters and stimulation protocols that elicit responses. We have established conditions for transcranial stimulation of the nervous system in vivo, using the mouse somatomotor response. We report that (1) continuous-wave stimuli are as effective as or more effective than pulsed stimuli in eliciting responses, and responses are elicited with stimulus onset rather than stimulus offset; (2) stimulation success increases as a function of both acoustic intensity and acoustic duration; (3) interactions of intensity and duration suggest that successful stimulation results from the integration of stimulus amplitude over a time interval of 50 to 150 ms; and (4) the motor response elicited appears to be an all-or-nothing phenomenon, meaning stronger stimulus intensities and durations increase the probability of a motor response without affecting the duration or strength of the response.

View Article and Find Full Text PDF

A tissue-mimicking material (TMM) for the acoustic and thermal characterization of high-intensity focused ultrasound (HIFU) devices has been developed. The material is a high-temperature hydrogel matrix (gellan gum) combined with different sizes of aluminum oxide particles and other chemicals. The ultrasonic properties (attenuation coefficient, speed of sound, acoustical impedance, and the thermal conductivity and diffusivity) were characterized as a function of temperature from 20 to 70°C.

View Article and Find Full Text PDF

A single-voxel Carr-Purcell-Meibloom-Gill sequence was developed to measure localized T(2) relaxation times of (13)C-labeled metabolites in vivo for the first time. Following hyperpolarized [1-(13)C]pyruvate injections, pyruvate and its metabolic products, alanine and lactate, were observed in the liver of five rats with hepatocellular carcinoma and five healthy control rats. The T(2) relaxation times of alanine and lactate were both significantly longer in HCC tumors than in normal livers (p < 0.

View Article and Find Full Text PDF

A blood mimicking fluid (BMF) has been developed for the acoustic and thermal characterizations of high intensity focused ultrasound (HIFU) ablation devices. The BMF is based on a degassed and de-ionized water solution dispersed with low density polyethylene microspheres, nylon particles, gellan gum, and glycerol. A broad range of physical parameters, including attenuation coefficient, speed of sound, viscosity, thermal conductivity, and diffusivity, were characterized as a function of temperature (20-70 degrees C).

View Article and Find Full Text PDF

To address the challenges associated with measuring the ultrasonic power from high-intensity focused ultrasound transducers via radiation force, a technique based on pulsed measurements was developed and analyzed. Two focused ultrasound transducers were characterized in terms of an effective duty factor, which was then used to calculate the power during the pulse at high applied power levels. Two absorbing target designs were used, and both gave comparable results and displayed no damage and minimal temperature rise if placed near the transducer and away from the focus.

View Article and Find Full Text PDF

Background: Automated identification of cell cycle phases of individual live cells in a large population captured via automated fluorescence microscopy technique is important for cancer drug discovery and cell cycle studies. Time-lapse fluorescence microscopy images provide an important method to study the cell cycle process under different conditions of perturbation. Existing methods are limited in dealing with such time-lapse data sets while manual analysis is not feasible.

View Article and Find Full Text PDF

We demonstrate that high-frequency and high-intensity ultrasound (US) can be applied to both tissue fixation and tissue processing to complete the conventional overnight formalin-fixation and paraffin-embedding (FFPE) procedures within 1 hr. US-facilitated FFPE retains superior tissue morphology and long-term room temperature storage stability than conventional FFPE. There is less alteration of protein antigenicity after US-FFPE preservation so that rapid immunohistochemical reactions occur with higher sensitivity and intensity, reducing the need for antigen retrieval pretreatment.

View Article and Find Full Text PDF

Objective: Advances in ultrasound transducer array and amplifier technologies have prompted many intriguing scientific proposals for ultrasound therapy. These include both mildly invasive and noninvasive techniques to be used in ultrasound brain surgery through the skull. In previous work, it was shown how a 500-element hemisphere-shaped transducer could correct the wave distortion caused by the skull with a transducer that operates at a frequency near 0.

View Article and Find Full Text PDF

The need for efficient and controlled delivery is one of the major obstacles to clinical use of gene therapy. In this study, we investigated the use of magnetic resonance imaging-monitored ultrasound (US) to induce expression of luciferase after local injection of the construct Ad-HSP-Luc, an adenoviral vector containing a transgene encoding firefly luciferase under the control of the human hsp70B promoter. The hsp promoter allows induction of the associated transgene only in areas that are subsequently heated after infection.

View Article and Find Full Text PDF

The aim of this study was to test a prototype MRI-compatible focused ultrasound phased array system for trans-skull brain tissue ablation. Rabbit thigh muscle and brain were sonicated with a prototype, hemispherical 500-element ultrasound phased array operating at frequencies of 700-800 kHz. An ex vivo human skull sample was placed between the array and the animal tissue.

View Article and Find Full Text PDF

The purpose of this study was to test the utility of MR thermometry for monitoring the temperature rise on the brain surface and in the scalp induced by skull heating during ultrasound exposures. Eleven locations in three pigs were targeted with unfocused ultrasound exposures (frequency = 690 kHz; acoustic power = 8.2-16.

View Article and Find Full Text PDF

MRI-guided focused ultrasound was tested in the brains of rhesus monkeys. Locations up to 4.8 cm deep were targeted.

View Article and Find Full Text PDF

In this study, we investigated the use of MRI-derived thermal imaging for determining the exposure parameters for focused ultrasound (FUS) surgery. Since the temperature rise induced by a FUS beam scales linearly with power, the temperature maps acquired during subthreshold sonications can be used to determine the power necessary to produce thermal tissue damage with a desired size. Thermal images acquired during multiple sonications delivered at different locations in rabbit thigh muscle and brain tissue in vivo were analyzed to test this hypothesis.

View Article and Find Full Text PDF