Objectives: To study the changes in vessel densities (VD) stratified by vessel diameter in the retinal superficial and deep vascular complexes (SVC/DVC) using optical coherence tomography angiography (OCTA) images obtained from people with diabetes and age-matched healthy controls.
Methods: We quantified the VD based on vessel diameter categorized as <10, 10-20 and >20 μm in the SVC/DVC obtained on 3 × 3 mm OCTA scans using a deep learning-based segmentation and vascular graph extraction tool in people with diabetes and age-matched healthy controls.
Results: OCTA images obtained from 854 eyes of 854 subjects were divided into 5 groups: healthy controls (n = 555); people with diabetes with no diabetic retinopathy (DR, n = 90), mild and moderate non-proliferative DR (NPDR) (n = 96), severe NPDR (n = 42) and proliferative DR (PDR) (n = 71).
Purpose: To evaluate the effect of variable corneal thickness on Pentacam HR diagnostic indices in normal corneas.
Methods: Retrospective study was conducted at Al Watany Eye Hospital, Cairo, Egypt. Consecutive 160 eyes of young myopic subjects without KC were evaluated using Pentacam HR (WaveLight Allegro Oculyzer II, Erlangen, Germany).
Purpose: To investigate the correlation between decentration index (index of height decentration, IHD) automatically calculated by the Pentacam HR software and the manually calculated inferior minus superior (I-S) value.
Setting: Al Watany Eye Hospital, Cairo, Egypt.
Methods: In a retrospective study, history taking, clinical examination, and rotating Scheimpflug camera scanning (by Oculyzer II equivalent to Pentacam HR) were done to 128 eyes: 82 normal, 24 forme fruste keratoconus FFKC (apparently normal cornea with evident keratoconus in the fellow eye), and 22 keratoconus (KC).
Purpose: The aim of this study was to find indices for keratoconus (KC) detection with higher sensitivity and specificity than the currently available ones with the rotating Scheimpflug imaging (Oculyzer I, Pentacam) software.
Patients And Methods: Data of 103 normal and 73 KC eyes imaged by Oculyzer I, including slit-lamp examination, refraction, Scheimpflug images, and follow-up data were collected. Logistic regression was done to find new indices with higher area under receiver operating characteristic curves using the currently available ones.
Purpose: To assess the effect of age on elevation and pachymetric Pentacam keratoconus (KC) detection indices, and the need to adjust normative values accordingly.
Methods: In a retrospective study, 95 eyes of myopic normal subjects without KC were evaluated using the OCULUS Pentacam, with an age range of 17.4 to 46.