Objective: To compare the fatigue behavior and reliability of 5 pressed lithium disilicate ceramics and a 5 mol% yttria-stabilized zirconia (5Y-TZP) when 3 dynamic loading protocols were used.
Methods: Bar-shaped specimens (30 × 4 × 3 mm) were fabricated from 5 pressed lithium disilicate ceramics (AMB, CEL, INI, IPS, and LIV) and a 5Y-TZP (ZR) (N = 324). Six specimens from each material were subjected to a static 4-point fracture load test, while the remaining specimens were subjected dynamic loading by increasing the starting load (30 % of the static fracture load) in every 5000 cycles by 50 N (loading protocol 1), in every 5000 cycles by 5 % (loading protocol 2) or in every 1000 cycles by 10 N (loading protocol 3) until fracture (n = 16).
Int J Environ Res Public Health
July 2024
(1) Background: Insufficient data exist regarding oral function among older adults in Europe. Therefore, we aimed to assess and compare oral function between older in- and outpatients and identify predictors of low masticatory performance. (2) Methods: Patients were consecutively recruited from the outpatient center ( = 31) and the inpatient geriatric department ( = 31) at a tertiary University Hospital in Switzerland in 2023.
View Article and Find Full Text PDFObjectives: To assess the mechanical durability of monolithic zirconia implant-supported fixed dental prostheses (iFDP) design on one implant, with a distal and a mesial extension cantilever bonded to a titanium base compared to established designs on two implants.
Materials And Methods: Roxolid Tissue level (TL), and tissue level x (TLX) implants were used to manufacture screw-retained 3-unit iFDPs (n = 60, n = 10 per group), with following configurations (X: Cantilever; I: Implant, T: Test group, C: Control group): T1: X-I-X (TL); T2: X-I-X (TLX); T3: I-I-X (TL); T4: I-I-X (TLX); C1: I-X-I (TL); C2: I-X-I (TLX). The iFDPs were thermomechanically aged and subsequently loaded until fracture using a universal testing machine.
Purpose: To investigate the bending moment of implants restored with a directly screwed single-unit fixed dental prosthesis (FDP) compared to implants restored with an FDP polymerized to a titanium base before and after thermomechanical aging.
Materials And Methods: A total of 240 implants (120 with and 120 without a titanium base) were restored with FDPs manufactured from conventionally sintered 3Y-TZP, 5Y-TZP, 4Y-TZP, and CoCrMo, as well as high-speed sintered 4Y-TZP. Half the specimens per subgroup were aged using chewing simulation combined with thermocycling (1,200,000 cycles at 50 N; 6,000 cycles at 5° to 55°).
Objectives: The aim of Working Group 4 was to address patient benefits associated with implant dentistry. Focused questions on (a) dental patient-reported outcomes (dPROs), (b) improvement in orofacial function, and (c) preservation of orofacial tissues in partially and fully edentulous patients following provision of implant-retained/supported dental prostheses were addressed.
Materials And Methods: Three systematic reviews formed the basis for discussion.
Althouh cone beam computed tomography (CBCT) is popular for dental implant planning, the horizontal mesiodistal space of the edentulous ridge is still conventionally measured with a handheld sliding caliper in the oral cavity or on a plaster cast. For clinical application in implant planning, our aim was to evaluate the accuracy of CBCT horizontal mesiodistal linear measurements in comparison with conventionally obtained direct measurements on plaster casts. Postoperative CBCT acquisitions and plaster casts of 27 patients with adjacent posterior mandibular implants were analyzed in a prospective clinical study.
View Article and Find Full Text PDFObjectives: The aim of this study is to investigate the influence of the material and corresponding sintering protocol, layer thickness, and aging on the two-body wear (2BW) and fracture load (FL) of 4Y-TZP crowns.
Materials And Methods: Multi-layer 4Y-TZP crowns in three thicknesses (0.5 mm/1.
Objectives: To test and compare two types of implant systems restored with four monolithic polymer-based materials with regard to their bending moments (BM) before and after aging.
Methods: A total of 192 tissue-level implants (TRI Dental Implants) differing in the presence (TiB, Octa line, n = 96) or absence (NTiB, Matrix line, n = 96) of a titanium base were restored with mandibular right first molar crowns manufactured from composite (CC), polymer-infiltrated ceramic (VE), PMMA (PM) and a 3D printed resin (ND) (n = 24). Half of the specimens (n = 12) were loaded for 1,200,000 cycles (50 N, 1.
J Mech Behav Biomed Mater
June 2022
Objectives: This investigation evaluated the impact of multiple firings during the veneering process of anterior all-ceramic restorations on the fracture load (FL) of zirconia crowns veneered with different ceramics (ZRT, ZRO, HFZ, STR).
Methods: All-ceramic crowns with anatomically reduced zirconia frameworks were prepared using four different veneering ceramics (N = 192/n = 48 per veneering ceramic). The crowns were fired 2 and 10 times.
Objectives: This investigation evaluated the impact of multiple firings during the veneering process of all-ceramic restorations on the thermal properties and bond strength between veneering ceramics and zirconia.
Methods: For the measurements of the coefficient of thermal expansion (CTE) prismatic specimens of four different veneering ceramics (ZRT/ZRO/HFZ/STR; N = 40/n = 10 per veneering ceramic) and rod-shaped zirconia specimens (N = 2) were produced. 2 specimens of each veneering ceramic were fired 2, 4, 6, 8, and 10 times simulating dentine-firing.
This clinical report describes the treatment of a complex intraoral situation by fabricating a maxillary implant-retained overdenture with a high-performance polymer (polyetherketoneketone) framework and lithium disilicate crowns and mandibular tooth- and implant-supported ceramic restorations. No complications were noted in 2 years, and the patient was satisfied with function and esthetics.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
July 2021
Purpose: Evaluation of the effect of three different dynamic fatigue protocols on the fracture resistance of two monolithic strength-gradient zirconia materials.
Materials And Methods: A total of 240 specimens (3 × 4 × 45 mm) was milled from two different layers (incisal and middle) of two types of strength-gradient zirconia blanks (IPS e. max ZirCAD MT Multi A2 vs.
Objective: This randomized controlled trial (RCT) aimed to demonstrate the non-inferiority of mandibular 2-implant overdentures (IODs) on a CAD-CAM milled bar with long distal extensions (MBDE) against IODs on retentive anchors (RA).
Methods: Forty edentulous participants rehabilitated with a maxillary conventional denture and a mandibular 2-IOD participated in this trial. They were randomized into two groups [Control group (CG): RA + gold matrices; Experimental group (EG): MBDE + gold clip].
The present investigation tested the effect of the cleaning method on the tensile bond strength (TBS) between one resin composite cement (RCC) and three different computer aided design/computer aided manufacturing (CAD/CAM) materials, namely zirconia, lithium disilicate ceramic and resin composite. Ninety specimens were prepared from each CAD/CAM material (N = 270). The specimens were pre-treated respectively, divided into five subgroups and subjected to five different cleaning protocols, namely i.
View Article and Find Full Text PDFObjectives: This retrospective clinical study investigates the frequency of biological and technical complications in patients rehabilitated by natural root-retained overdentures (RODs) with cast post-and-cores (root caps) wearing precision attachments and analyses factors influencing complication rates (e.g. oral hygiene routines).
View Article and Find Full Text PDFObjective: To investigate the effect of surgical guide support and implant site location on the accuracy of static Computer-Assisted Implant Surgery (sCAIS) in partially edentulous patients.
Materials And Methods: 375 replica implants were inserted in 85 study models. Surgical implant placement was done using static 3D printed surgical guides, which were designed to be supported either by all the teeth present in the model (full arch), or by 4-teeth), 3-teeth or 2-teeth.
Objectives: To validate a purpose-built two-coloured chewing gum (Hue-Check Gum ), and to test the accuracy of a custom-built smartphone application for a colour-mixing ability test to assess chewing function.
Methods: Fully dentate participants (28D-group) and edentulous participants with implant overdentures (IOD-group) were recruited. They chewed a Hue-Check Gum for 5, 10, 20, 30 and 50 chewing cycles, respectively.
The purpose of this case series was to assess safety and feasibility of a novel resorbable collagen matrix (CMX) to enhance tissue thickness simultaneous with implant placement and guided bone regeneration (GBR) in esthetic sites over an 8-week healing period. Soft tissue thickness at implant sites and adjacent teeth was monitored with an ultrasonic device. Overall tissue contour changes were assessed by sequential digital surface model superimpositions.
View Article and Find Full Text PDFPurpose: To describe the survival rate and peri-implant bone loss in very old patients dependent for their activities of daily living (ADL), treated with mandibular two-implant overdentures (IODs) in the context of a previously reported randomized controlled trial.
Materials And Methods: A total of 19 patients received two interforaminal Straumann implants (Regular Neck, 4.1 mm diameter, 8 mm length) that were subsequently loaded with Locator attachments, transforming their preexisting inferior conventional denture into an IOD.
Background: Long-term studies of ≥10 years are important milestones to get a better understanding of potential factors causing implant failures or complications.
Purpose: The present study investigated the long-term outcomes of titanium dental implants with a rough, microporous surface (titanium plasma sprayed [TPS]) and the associated biologic and technical complications in partially edentulous patients with fixed dental prostheses over a 20-year follow-up period.
Materials And Methods: Sixty-seven patients, who received 95 implants in the 1980s, were examined with well-established clinical and radiographic parameters.