In contrast with the information of the inspection body concerning the use of ronidazole, several non compliant muscle samples were detected using a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method in accordance with confirmation criteria of Decision 2002/657/EC. This led to the suspicion that non compliance could be due to false positive results. In this context, a liquid chromatography-high resolution mass spectrometry (LC-HRMS) method was developed and sample extracts were re-analyzed, resolving the co eluting isobaric interfering peak, which also has an interfering product ion with the transition product (m/z 201>140).
View Article and Find Full Text PDFSensitive and unequivocal determination of analytes/contaminants in complex matrices is a challenge in the field of food safety control. In this study, various acquisition modes (Full MS/AIF, Full MS+tMS/MS, Full MS/dd MS/MS and tSIM/ddMS/MS) and parameters of a quadrupole-orbitrap hybrid mass spectrometer (Q Exactive) were studied in detail. One of the main conclusions has been that, reducing the scan range for Full MS (using the quadrupole) and targeted modes give higher signal-to-noise (S/N) ratios and thereby better detection limits for analytes in matrix.
View Article and Find Full Text PDFTwo methods based on liquid chromatography-tandem mass spectrometry were developed for the determination of ten aminoglycosides (streptomycin, dihydrostreptomycin, spectinomycin, apramycin, paromomycin, kanamycin A, gentamycin C1, gentamycin C2/C2a, gentamycin C1a, and neomycin B) in kidney samples from food-producing animals and in honey samples. The methods involved extraction with an aqueous solution (for the kidney samples) or sample dissolution in water (for the honey samples), solid-phase extraction with a weak cation exchange cartridge and injection of the eluate into a liquid chromatography-tandem mass spectrometry system. A zwitterionic hydrophilic interaction chromatography column was used for separation of aminoglycosides and a triple quadrupole mass analyzer was used for detection.
View Article and Find Full Text PDFAn analytical method for the analysis of six fluoroquinolones (FQs) in animal feeds was developed. The sample treatment consists of a simple and rapid extraction of the analytes by manual shaking with an acetonitrile-water mixture containing hydrochloric acid without further sample cleanup. Matrix effects were minimized by diluting the extract with water.
View Article and Find Full Text PDFThe effect of mobile-phase constituents (pH and ionic strength) and chromatographic behaviour of ten aminoglycosides (streptomycin, dihydrostreptomycin, spectinomycin, apramycin, paramomycin, kanamycin A, gentamycin C1, gentamycin C2/C2a, gentamycin C1a and neomycin) in the bare silica, amino, amide and zwitterionic phases of hydrophilic interaction chromatography (HILIC) were studied systematically. Among the stationary phases studied, the zwitterionic phase provided the best separation of aminoglycosides. The effect of pH, ionic concentration and column temperature on retention time, peak shape and sensitivity was studied using a central composite design.
View Article and Find Full Text PDFTwo analytical methodologies for the simultaneous analysis of eight sulfonamide antibiotics in animal feeds were developed. Analytes were extracted in a simple and rapid procedure by manual shaking with an ethyl acetate/ultrapure water mixture (99:1, v/v) without further sample cleanup. Mean recoveries ranging from 72.
View Article and Find Full Text PDFAn enzyme-linked immunosorbent assay (ELISA) to screen sulfadiazine and sulfamethazine residues in feeds has been developed and validated according to Commission Decision 2002/657/EC criteria. Sulfonamides are easily extracted with a 95:5 acetonitrile/water mixture, obtaining recoveries between 80 and 100%. Accuracy, precision, selectivity, robustness, limit of detection (LOD), and detection capability (CCbeta) of the assay have been assessed during the validation process.