The main aim of this study was to determine key factors that regulate fire-retardant effectiveness of intumescent coatings comprising of ammonium polyphosphate, melamine, pentaerythritol, polymer binder. Fulfillment of the research objectives resulted in the development of a coating with R120 fire resistance. The expected service life of the coating is at least 15 years when applied at Z2 type of environmental conditions (indoor use).
View Article and Find Full Text PDF