Background: Percutaneous balloon pulmonary valvuloplasty (PBPV) is the treatment of choice for hemodynamically significant pulmonary stenosis (PS). Currently, the Tyshak balloon is preferred but requires multiple dilatations because of its instability across the valve leading to a watermelon seeding effect. Accura balloon (Vascular Concept, UK) offers an advantage in its self-positioning configuration, variable diameter, and rapid inflation-deflation sequence which shortens the procedural time and valve injury.
View Article and Find Full Text PDF"Tiger stripes" or "Zebra stripes" are multiple band-like signals noted on Doppler spectral recordings and have been associated with intracardiac oscillating structures. They have been attributed to flail prosthetic valve leaflet, native valve regurgitation without flail leaflet, papillary muscle rupture in acute coronary syndrome, and possibly Lambl's excrescences. To our knowledge, there is only one case report in the English literature that had identified this sign in rheumatic carditis.
View Article and Find Full Text PDFSoc Netw Anal Min
October 2022
In recent decades, sellers and merchants have asked their customers to share their opinion on the products at online marketplace. Analysis of the massive amounts of reviews for a potential customer is an immense challenge, to decide whether to purchase a product or not. In this paper, a hierarchical attention network-based framework is presented to resolve this challenge.
View Article and Find Full Text PDFBackground: Atrial septal defect (ASD) is one of the common congenital heart defects. Its management has transformed dramatically in the last 4 decades with the transition from surgical to percutaneous transcatheter closure for most secundum-type ASDs. Various devices are available for transcatheter closure of ASD with Amplatzer atrial septal occluder being most commonly used worldwide.
View Article and Find Full Text PDFHydrotalcite-like anionic clays (HTs) also known as Layered double hydroxides (LDHs) have been developed as multifunctional materials in numerous applications related to catalysis, adsorption, and ion-exchange processes. These materials constitute an important class of ionic lamellar solid clays of Brucite-like structure which comprise of consecutive layers of divalent and trivalent metal cations with charge balancing anions and water molecules in interlayer space. These materials have received increasing attention in research due to their interesting properties namely layered structure, ease of preparation, flexible tunability, ability to intercalate different types of anions, electronic properties, high thermal stability, high biocompatibility, and easy biodegradation.
View Article and Find Full Text PDFBackground: During ongoing coronavirus disease 2019 (COVID-19) pandemic, social isolation and lockdown measures were implemented to prevent spread of virus which created enormous challenges to patient healthcare. In order to overcome these challenges, teleconsultation (telecardiology) was initiated. Objective of this study was to assess outcome of telecardiology using audio/visual/audio-visual consultation among patients with implantable cardiac devices.
View Article and Find Full Text PDFBackground: Temporary pacing is usually performed by cardiologists under fluoroscopic, echocardiographic, or ECG guidance. However, in the developing world, there are inadequate number of cardiologists, and C-arm, catheterization laboratories, or echocardiography are not available at primary or secondary healthcare facilities. In addition, in emergencies option of fluoroscopy and echocardiography is limited.
View Article and Find Full Text PDFObjective To evaluate the impact of successful percutaneous balloon mitral valvuloplasty (BMV) on left atrial (LA) reservoir function and LA volume in patients with severe mitral stenosis (MS) using peak atrial longitudinal strain (PALS). Method This was a prospective, non-randomized observational study conducted at the Laxmipat Singhania (LPS) Institute of Cardiology, Kanpur from August 2018 to February 2020 among patients with severe rheumatic MS undergoing BMV to assess LA reservoir function and its volume after BMV using PALS. Inclusion criteria were symptomatic severe rheumatic MS (NYHA ≥II), normal ventricular systolic function, and suitable valve morphology.
View Article and Find Full Text PDFBackground: Provisional stenting is preferred for bifurcation lesion; however, certain anatomical substrate does require two stents as a part of dedicated stent technique. Here, the present study evaluated outcomes of ultra-thin (60 µm) Supra family sirolimus-eluting stent (SES) (Sahajanand Medical Technologies Limited, Surat, India) for dedicated bifurcation lesions using nano-crush technique at 12 months angiographic follow-up.
Methods: This was prospective, single-center observational study which enrolled patients with de novo bifurcation lesion and underwent angioplasty with Supra family SES using nano-crush technique at a tertiary care center in India, between March-2017 and February-2019.
J Saudi Heart Assoc
October 2021
Objective: Aim of study was to evaluate safety and efficacy of abluminal Mitigator DES + Sirolimus Eluting Stent (Envision Scientific, Surat, India) incorporating novel technology of fusion coating of bioresorbable polymer on both abluminal surface of stent and exposed parts of balloon among real world patients specially focusing younger patients (<35 years).
Method: 1293 patients received Mitigator DES + at LPS Institute of Cardiology, Kanpur, India. Primary outcome was target lesion failure (TLF)- composite of cardiovascular death, target vessel myocardial infarction (TVMI), and target lesion revascularization (TLR) and secondary end points including peri-procedural device failure (failure of stent delivery, change of stent, stent fracture), target vessel failure (TVF), and patient oriented composite end point (POCE)-composite of all deaths, MI, and revascularization and stent thrombosis (ST) at 1-year follow-up.
Background: Coronary no-reflow (NRF) following percutaneous coronary intervention (PCI) is infrequent but one of the most dreaded complication which results from impaired flow of microvascular bed. It is associated with adverse outcome if flow is not restored. Objective of this study was to find safety, effectiveness and outcome of intracoronary nikorandil (IC) administered using perforated balloon technique (PBT) to reverse NRF.
View Article and Find Full Text PDFObjectives: -This prospective study with a sizable cohort was undertaken to assess changes in left and right ventricle systolic and diastolic functions after percutaneous patent ductus arteriosus device closure with appropriate follow up evaluation.
Methods: - It is an observational analytical prospective study. Ninety-eight patients were recruited out of which sixty-eight patients underwent percutaneous PDA device closure and were taken for final analysis.
Objectives: Though invasive monitoring is the most accurate to estimate diastolic dysfunction but it has its own risk. The purpose of this study was to find out any standardized correlation between invasive and non -invasive parameters.
Methods: It is an observational, descriptive study comprising of a total of 500 patients.
Background: Long and multiple lesions especially in the background of tortuous coronary artery often require multiple stents. The entry and passage of another stent through an already deployed stent becomes challenging because of poorly expanded stent struts, calcified tissue, underlying tortuosity, highly angulated takeoff of the vessel, and lack of coaxiality. It can be facilitated by balloon deflection technique (BDT) where balloon at proximal edge of main vessel stent over a buddy wire helps to deflect second stent either distally or into side branch by blocking potential dead.
View Article and Find Full Text PDFArch Med Sci Atheroscler Dis
December 2020
Introduction: No-reflow is an infrequent but dreaded complication of percutaneous coronary intervention (PCI), where the culprit is obstruction of the downstream microvascular bed. The aim of this study was to evaluate the efficacy and safety of forceful injection of blood (autologous blood transfusion - ABT) in reversing no-reflow during PCI because data regarding its effectiveness is not available.
Material And Methods: 100-120 ml of blood was withdrawn through guiding catheter over 3 to 5 min using a 10 ml syringe and re-infused by forceful injection over 3 min through it, and its efficacy was assessed at 10 min using TIMI flow grade and quantitative corrected TIMI frame count.
Background: Safety and efficacy of newer-generation and World's thinnest everolimus eluting stent (Evermine 50) in patients with very long and multiple lesions.
Method: Total of 711 patients received >40 mm long, World's thinnest (50 µm) Evermine 50 Everolimus eluting stent (Meril Life Sciences Pvt. Ltd.
Objectives: This is an open-label randomized control trial with a parallel assignment with single masking comparing patients undergoing coronary angiography via dorsal radial and classical radial access.
Methods: Study done at three tertiary cardiac care centers for two years. A total of 970 patients were finally recruited for the study.
Pulmonary arterio-venous fistula is an uncommon cause of cyanosis and should be suspected when normal cardiac examination is associated without evidence of intra-cardiac shunt. Diagnosis of extra-cardiac shunt can be suspected by contrast echocardiography using agitated saline and confirmation of pulmonary arterio-venous fistula can be made by computed tomography pulmonary angiography with information regarding the size feeding vessels necessary for the planning of intervention. With the advancement of trans-catheter devices, fistula can be occluded successfully by embolotherapy.
View Article and Find Full Text PDFBackground: Of almost 5.7 million Americans with heart failure, 80% are 65 years and older. Empowerment approaches facilitating recognition of personal and social contextual resources may improve well-being in this vulnerable population.
View Article and Find Full Text PDFBackground: Lesion characteristics (anatomy, calcification, tortuosity and angulation), vessel morphology, and lack of support add complexity of coronary intervention. Guidezilla catheter, acting as an extension of guide catheter system (mother-in-child catheter), helps to overcome these complexities by enhancing backup during complex intervention.
Methods: The present retrospective, single-center study included 13,157 consecutive patients who underwent percutaneous coronary intervention (PCI) through both transfemoral and transradial routes from January 2015 to July 2019 at LPS Institute of Cardiology, G.
Background: Among patients undergoing intervention involving venous access, various techniques have been implemented to achieve hemostasis in order to reduce local access site complications, to decrease length of stay and to facilitate early ambulation. We aimed to assess the efficacy and safety of fellow's stitch using "fisherman's knot" (figure of Z (FoZ)) technique when compared with conventional manual compression for immediate closure of large venous sheath (> 10 French (Fr)).
Methods: Between November 2012 and March 2019, 949 patients underwent various interventions which involved venous access requiring hemostasis.
Background: Positioning a permanent pacing wire in patients with persistent left superior vena cava (PLSVC) to right ventricle often comes as on-table surprise. It is technically demanding and therefore most of operators prefer left-sided approach. We assessed technical challenges during pacemaker implantation, and their short- and long-term outcomes among patients with isolated PLSVC from a right-sided approach.
View Article and Find Full Text PDFCongenital coronary artery anomalies are rare and usually an incidental finding during coronary angiography. Most of the anomalies are benign in nature; however, some are malignant and may result in sudden cardiac death. A 46-year-old woman with diabetes and hypertension underwent coronary angiography for evaluation of exertional angina, which revealed an unusual trifurcation of a single left coronary artery with an anomalous origin of the right coronary artery from the left anterior descending artery but no significant coronary narrowing.
View Article and Find Full Text PDF