IEEE Trans Biomed Eng
November 2024
Over the past decade, ultrasound microvasculature imaging has seen the rise of highly sensitive techniques, such as ultrafast power Doppler (UPD) and ultrasound localization microscopy (ULM). The cornerstone of these techniques is the acquisition of a large number of frames based on unfocused wave transmission, enabling the use of singular value decomposition (SVD) as a powerful clutter filter to separate microvessels from surrounding tissue. Unfortunately, SVD is computationally expensive, hampering its use in real-time UPD imaging and weighing down the ULM processing chain, with evident impact in a clinical context.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
October 2024
Ultrasound open scanners have recently boosted the development and validation of novel imaging techniques. They are usually split into hardware- or software-oriented systems, depending on whether they process the echo data using embedded FPGAs/DSPs or a GPU on a host PC. The goal of this work was to realize a high-performance heterogeneous open scanner capable of leveraging the strengths of both hardware and software-oriented systems.
View Article and Find Full Text PDFIn this study, we demonstrate that a deep neural network (DNN) can be trained to reconstruct high-contrast images, resembling those produced by the multistatic Synthetic Aperture (SA) method using a 128-element array, leveraging pre-beamforming radiofrequency (RF) signals acquired through the monostatic SA approach. : A U-net was trained using 27200 pairs of RF signals, simulated considering a monostatic SA architecture, with their corresponding delay-and-sum beamformed target images in a multistatic 128-element SA configuration. The contrast was assessed on 500 simulated test images of anechoic/hyperechoic targets.
View Article and Find Full Text PDFBrachial artery flow-mediated dilation (BAFMD) is induced by hyperemic wall shear rate (WSR) following forearm ischemia. In older adults, there appears to be a reduced brachial hyperemic WSR and altered stimulus-response relationship compared with young adults. However, it is unclear if an altered forearm microvascular response to ischemia influences brachial hyperemic WSR in older adults.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
February 2023
Coherent multi-transducer ultrasound (CoMTUS) creates an extended effective aperture through the coherent combination of multiple arrays, which results in images with enhanced resolution, extended field-of-view, and higher sensitivity. The subwavelength localization accuracy of the multiple transducers required to coherently beamform the data is achieved by using the echoes backscattered from targeted points. In this study, CoMTUS is implemented and demonstrated for the first time in 3-D imaging using a pair of 256-element 2-D sparse spiral arrays, which keep the channel count low and limit the amount of data to be processed.
View Article and Find Full Text PDFBackground: The original observation that lung ultrasound provides information regarding the physical state of the organ, rather than the anatomical details related to the disease, has reinforced the idea that the observed acoustic signs represent artifacts. However, the definition of artifact does not appear adequate since pulmonary ultrasound signs have shown valuable diagnostic accuracy, which has been usefully exploited by physicians in numerous pathologies.
Method: A specific method has been used over the years to analyze lung ultrasound data and to convert artefactual information into anatomical information.
IEEE Trans Ultrason Ferroelectr Freq Control
October 2022
Two-dimensional (2-D) arrays offer volumetric imaging capabilities without the need for probe translation or rotation. A sparse array with elements seeded in a tapering spiral pattern enables one-to-one connection to an ultrasound machine, thus allowing flexible transmission and reception strategies. To test the concept of sparse spiral array imaging, we have designed, realized, and characterized two prototype probes designed at 2.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
October 2022
Spiral array transducers with a sparse 2-D aperture have demonstrated their potential in realizing 3-D ultrasound imaging with reduced data rates. Nevertheless, their feasibility in high-volume-rate imaging based on unfocused transmissions has yet to be established. From a metrology standpoint, it is essential to characterize the acoustic field of unfocused transmissions from spiral arrays not only to assess their safety but also to identify the root cause of imaging irregularities due to the array's sparse aperture.
View Article and Find Full Text PDFUltrasound Med Biol
August 2022
Stress echocardiography helps to diagnose cardiac diseases that cannot easily be detected or do not even manifest at rest. In clinical practice, assessment of the stress test is usually performed visually and, therefore, in a qualitative and subjective way. Although speckle tracking echocardiography (STE) has been proposed for the quantification of function during stress, its time resolution is inadequate at high heart rates.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
October 2022
An ultrasound sparse array consists of a sparse distribution of elements over a 2-D aperture. Such an array is typically characterized by a limited number of elements, which in most cases is compatible with the channel number of the available scanners. Sparse arrays represent an attractive alternative to full 2-D arrays that may require the control of thousands of elements through expensive application-specific integrated circuits (ASICs).
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
December 2021
This work demonstrates that the combination of multi-line transmission (MLT) and short-lag spatial coherence (SLSC) imaging improves the contrast of highly coherent structures within soft tissues when compared to both traditional SLSC imaging and conventional delay and sum (DAS) beamforming. Experimental tests with small (i.e.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
October 2021
Volumetric ultrasound imaging of blood flow with microbubbles enables a more complete visualization of the microvasculature. Sparse arrays are ideal candidates to perform volumetric imaging at reduced manufacturing complexity and cable count. However, due to the small number of transducer elements, sparse arrays often come with high clutter levels, especially when wide beams are transmitted to increase the frame rate.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
June 2021
Ultrasound open platforms are programmable and flexible tools for the development and test of novel methods. In most cases, they embed the electronics for the independent control of (maximum) 256 probe elements. However, a higher number of channels is needed for the control of 2-D array probes.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
August 2021
High-frame-rate vector Doppler methods are used to measure blood velocities over large 2-D regions, but their accuracy is often estimated over a short range of depths. This article thoroughly examines the dependence of velocity measurement accuracy on the target position. Simulations were carried out on flat and parabolic flow profiles, for different Doppler angles, and considering a 2-D vector flow imaging (2-D VFI) method based on plane wave transmission and speckle tracking.
View Article and Find Full Text PDFTransducers with a larger aperture size are desirable in ultrasound imaging to improve resolution and image quality. A coherent multi-transducer ultrasound imaging system (CoMTUS) enables an extended effective aperture through the coherent combination of multiple transducers. In this study, the discontinuous extended aperture created by CoMTUS and its performance for deep imaging and through layered media are investigated by both simulations and experiments.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
May 2021
2-D sparse arrays may push the development of low-cost 3-D systems, not needing to control thousands of elements by expensive application-specific integrated circuits (ASICs). However, there is still some concern about their suitability in applications, such as Doppler investigation, which inherently involve poor signal-to-noise ratios (SNRs). In this article, a novel real-time 3-D pulsed-wave (PW) Doppler system, based on a 256-element 2-D spiral array, is presented.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
May 2021
High-frame-rate (HFR) speckle-tracking echocardiography (STE) assesses myocardial function by quantifying motion and deformation at high temporal resolution. Among the proposed HFR techniques, multiline transmission (MLT) and diverging wave (DW) imaging have been used in this context both being characterized by specific advantages and disadvantages. Therefore, in this article, we directly contrast both approaches in an in vivo setting while operating at the same frame rate (FR).
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
September 2020
Speckle tracking echocardiography (STE) is a clinical tool to noninvasively assess regional myocardial function through the quantification of regional motion and deformation. Even if the time resolution of STE can be improved by high-frame-rate (HFR) imaging, dedicated HFR STE algorithms have to be developed to detect very small interframe motions. Therefore, in this article, we propose a novel 2-D STE method, purposely developed for HFR echocardiography.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
May 2020
Ultrasound color Doppler imaging (CDI) provides a map of the axial blood flow velocities in a 2-D/3-D region of interest. While CDI is clinically effective for a qualitative analysis of abnormal blood flows, e.g.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
February 2020
One of the current challenges in ultrasound imaging is achieving higher frame rates, particularly in cardiac applications, where tracking the heart motion and other rapid events can provide potential valuable diagnostic information. The main drawback of ultrasound high-frame-rate strategies is that usually they partly sacrifice image quality in order to speed up the acquisition time. In particular, multi-line transmission (MLT), which consists in transmitting multiple ultrasound beams simultaneously in different directions, has been proven able to improve frame rates in echocardiography, unfortunately generating artifacts due to inter-beam crosstalk interferences.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
February 2020
The 2-D sparse arrays, in which a few hundreds of elements are distributed on the probe surface according to an optimization procedure, represent an alternative to full 2-D arrays, including thousands of elements usually organized in a grid. Sparse arrays have already been used in B-mode imaging tests, but their application to Doppler investigations has not been reported yet. Since the sparsity of the elements influences the acoustic field, a corresponding influence on the mean frequency (Fm), bandwidth (BW), and signal-to-noise ratio (SNR) of the Doppler spectra is expected.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
February 2020
High-frame-rate 3-D ultrasound imaging technology combined with super-resolution processing method can visualize 3-D microvascular structures by overcoming the diffraction-limited resolution in every spatial direction. However, 3-D super-resolution ultrasound imaging using a full 2-D array requires a system with a large number of independent channels, the design of which might be impractical due to the high cost, complexity, and volume of data produced. In this study, a 2-D sparse array was designed and fabricated with 512 elements chosen from a density-tapered 2-D spiral layout.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
January 2020
Major cardiovascular diseases (CVDs) are associated with (regional) dysfunction of the left ventricle. Despite the 3-D nature of the heart and its dynamics, the assessment of myocardial function is still largely based on 2-D ultrasound imaging, thereby making diagnosis heavily susceptible to the operator's expertise. Unfortunately, to date, 3-D echocardiography cannot provide adequate spatiotemporal resolution in real-time.
View Article and Find Full Text PDFKey Points: The vasodilatory response to reactive hyperaemia is impaired with advancing age, but it is unclear whether this is because of an altered wall shear rate (WSR) stimulus or an altered flow-mediated dilatation (FMD) response. Using new technology that allows detailed WSR measurement, we assessed the WSR-FMD response in healthy older people. Our data show that older people have a markedly altered and diminished WSR response to reactive hyperaemia compared to young people, but reduced WSR alone does not fully explain reduced FMD.
View Article and Find Full Text PDF