A series of 1-[3-(4-methyl piperazin-1-ylmethyl) phenylsulfonyl]-1H-indole and 1-[3-(4-ethyl piperazin-1-ylmethyl) phenylsulfonyl]-1H-indole derivatives were designed and synthesized as 5-HT receptor (5-HTR) ligands. The lead compound 1-[4-methyl-3-(4-methyl piperazin-1-yl methyl) phenylsulfonyl]-1H-indole dihydrochloride (6b), in this series, has shown potent in vitro binding affinity, selectivity, good pharmacokinetics (PK) profile and activity in the animal models of cognition.
View Article and Find Full Text PDFA series of N'-[3-(indole-1-sulfonyl) aryl]-N,N-dimethyl ethane-1,2-diamines and N'-[3-(indole-1-sulfonyl) aryl]-N,N-dimethyl propane-1,3-diamines was designed and synthesized as 5-HT6 receptor ligands. These compounds, when screened in a functional reporter gene-based assay, displayed potent antagonistic activity with Kb values in the range of 1.8-60 nM.
View Article and Find Full Text PDF4-(Piperazin-1-yl methyl)-N(1)-arylsulfonyl indole derivatives were designed and synthesized as 5-HT(6) receptor (5-HT(6)R) ligands. The lead compound 6a, from this series shows potent in vitro binding affinity, good PK profile, no CYP liabilities and activity in animal models of cognition.
View Article and Find Full Text PDFThe design, synthesis and SAR of novel tetrahydrocarbazole derivatives having 5-HT(6) receptor antagonist activity is presented. The racemic compound 15e was found to possess desirable pharmacokinetic properties, adequate brain penetration and activity in animal models of cognition.
View Article and Find Full Text PDF5-Hydroxytryptamine 6 receptors (5-HT(6)R) are being perceived as the possible target for treatment of cognitive disorders as well as obesity. The present article deals with the design, synthesis, in vitro binding and structure-activity relationship of a novel series of tetracyclic tryptamines with the rigidized N-arylsulphonyl, N-arylcarbonyl and N-benzyl substituents as 5-HT(6) receptor ligands. The chiral sulphonyl derivatives 15a and 17a showed high affinity at 5-HT(6)R with the K(i) of 23.
View Article and Find Full Text PDFN(1)-Arylsulfonyl-3-piperazinyl indole derivatives were designed and identified as a novel class of 5-HT(6) receptors ligands. All the compounds have high affinity and antagonist activity towards 5-HT(6) receptor. The compound 7a (K(i) = 3.
View Article and Find Full Text PDFThe exclusive distribution of 5-HT6 receptors in the brain regions associated with learning and memory makes it an ideal target for cognitive disorders. A novel series of 5-piperazinyl methyl-N 1-aryl sulfonyl indoles were designed and synthesized as 5-HT6R ligands. Most of the synthesized compounds are potent when tested by in vitro radioligand binding assay.
View Article and Find Full Text PDFA series of novel aryl aminosulfonamides was designed and synthesized as 5-HT(6) receptor ligands. Many compounds screened in a functional reporter gene based assay displayed potent antagonistic activity with Kb values in the range of 0.02-10nM.
View Article and Find Full Text PDFThe synthesis and potential 5-hydroxytryptamine(6) receptor (5-HT6R) antagonist activity of a novel series of N-arylsulfonyl-3-(2-N,N-dimethylaminoethylthio) indoles has been reported. The molecular modeling, synthesis and in-vitro radioligand binding data of this series are discussed. The present article describes 37 derivatives of the title series.
View Article and Find Full Text PDFA high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the quantification of pramipexole in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H](+) ions, m/z 212/152 for pramipexole and m/z 409/228 for the IS. The method exhibited a linear dynamic range of 200-8000 pg/mL for pramipexole in human plasma.
View Article and Find Full Text PDFA simple, rapid, sensitive, and selective liquid chromatography-tandem mass spectrometry method is developed and validated for the quantitation of galantamine, an acetylcholinesterase inhibitor in human plasma, using a commercially available compound, loratadine, as the internal standard. Following liquid-liquid extraction, the analytes are separated using an isocratic mobile phase on a reverse-phase C18 column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective (M+H)+ ions, m/z 288 to 213 for galantamine and m/z 383 and 337 for the internal standard. The assay exhibit a linear dynamic range of 0.
View Article and Find Full Text PDFA simple, sensitive and rapid high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of pseudoephedrine in human plasma using mosapride as internal standard. Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple-reaction monitoring mode using the respective [M + H](+) ions, m/z 166/148 for pseuoephedrine and m/z 422/198 for the IS. The method exhibited a linear dynamic range of 2-1000 ng/mL pseudoephedrine in human plasma.
View Article and Find Full Text PDFA rapid high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry method was developed and validated for the quantification of fexofenadine in human plasma using mosapride as internal standard. Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 502/466 for fexofenadine and m/z 422/198 for the IS. The method exhibited a linear dynamic range of 1-500 ng/mL for fexofenadine in human plasma.
View Article and Find Full Text PDFObjective: The present study aimed at investigating the effects of concomitant food intake on the bioavailability of a single oral dose of clopidogrel (CAS 113665-84-2).
Methods: Clopidogrel was given under two conditions separated by a 14-day washout period: fasted and fed (after a standardized high fat breakfast). Concentrations of clopidogrel in plasma were quantified by a validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) with positive ion electro-spray ionization using multiple reaction monitoring (MRM).
A sensitive high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (MS/MS) method was developed and validated for the simultaneous quantification of trandolapril and its metabolite trandolaprilat in human plasma using ramipril as an internal standard. Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M-H]- ions, m/z 429/168 for trandolapril, m/z 401/168 for trandolaprilat and m/z 415/166 for the internal standard. The method exhibited a linear dynamic range of 20-10,000 pg/mL for both trandolapril and trandolaprilat in human plasma.
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
April 2007
A simple, sensitive and selective high performance liquid chromatography (HPLC) method with ultraviolet detection (272 nm) was developed and validated for the simultaneous quantification of theophylline and etofylline in human plasma. Following rapid sample preparation, the analytes and internal standard (hydrochlorothiazide) were separated using an isocratic mobile phase on a reverse phase C18 column. The lower limit of quantification was 100 ng/mL for both theophylline and etofylline with a relative standard deviation of less than 6%.
View Article and Find Full Text PDFTo support the pharmacokinetic and bioavailability study of a once-daily fexofenadine/pseudoephedrine combination, a high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry (HPLC/ESI-MS/MS) method for the simultaneous quantification of fexofenadine and pseudoephedrine was developed and validated with 500 microL human plasma using mosapride as an internal standard (IS). Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 502/466 for fexofenadine, m/z 166/148 for pseuoephedrine and m/z 422/198 for the IS. The method exhibited linear dynamic ranges of 1-500 ng/mL and 2-1000 ng/mL for fexofenadine and pseudoephedrine, respectively, in human plasma.
View Article and Find Full Text PDFA simple, sensitive and selective high-performance liquid chromatography (HPLC) method with ultraviolet detection (230 nm) was developed and validated for the quantification of oxcarbazepine (CAS 28721-07-5), a new antiepileptic drug, and its active metabolite 10-hydroxycarbazepine (CAS 29331-92-8) in human plasma. Following solid-phase extraction, the analytes and internal standard (zaleplon, CAS 151319-34-5) were separated using an isocratic mobile phase on a reverse phase C18 column. The lower limit of quantification was 50 ng/mL for oxcarbazepine and 100 ng/mL for 10-hydroxycarbazepine with a relative standard deviation of less than 10%.
View Article and Find Full Text PDFA rapid, sensitive and accurate liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of miglitol (CAS 72432-03-2), an alpha-glucosidase inhibitor, in human plasma using gabapentin (CAS 60142-96-3) as internal standard (IS). Following protein precipitation, the analytes were separated using an isocratic mobile phase on a reversed phase phenyl column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 208/146 for miglitol and m/z 172/154 for the IS. The assay exhibited a linear dynamic range of 100-6000 ng/mL for miglitol in human plasma.
View Article and Find Full Text PDFA simple, sensitive and rapid high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry (MS/MS) method was developed and validated for the assay of tizanidine in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by MS/MS in the selected reaction monitoring mode. The assay exhibited a linear dynamic range of 50-5000 pg/mL for tizanidine in human plasma.
View Article and Find Full Text PDFA simple, rapid, sensitive, and selective liquid chromatography-tandem mass spectrometry (MS) method was developed and validated for the quantification of metaxalone, a skeletal muscle relaxant, in human plasma using galantamine as internal standard (IS). Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse phase C18 column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 222/161 for metaxalone and m/z 288/213 for the IS. The assay exhibited a linear dynamic range of 50-5000 microg/L for metaxalone in human plasma.
View Article and Find Full Text PDFA simple, sensitive and selective high-performance liquid chromatography (HPLC) method with ultraviolet detection (305 nm) was developed and validated for quantification of cefditoren (CAS 104145-95-1), a broad-spectrum orally administered cephalosporin in human plasma. Following solid-phase extraction using Waters Oasis SPE cartridges, the analyte and internal standard (hydrochlorothiazide, CAS 58-93-5) were separated using an isocratic mobile phase of 0.03 % trifluoro acetic acid buffer / acetonitrile (81/19, v/ v) on reverse phase Waters symmetry C18 column.
View Article and Find Full Text PDFA simple, sensitive and rapid high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry method was developed and validated for the quantification of perindopril in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective [M+H](+) ions, m/z 369/172 for perindopril and m/z 417/234 for the internal standard. The method exhibited a linear dynamic range of 0.
View Article and Find Full Text PDFA simple, reliable HPLC method with fluorescence detection (excitation 320 and emission 388 nm) was developed and validated for quantitation of zolpidem in human plasma. Following a single-step liquid-liquid extraction, the analyte and internal standard (quinine) were separated using an isocratic mobile phase on a reversed-phase C(18) column. The lower limit of quantitation was 1.
View Article and Find Full Text PDFA simple, sensitive and rapid high-performance liquid chromatography/positive electrospray ionization tandem mass spectrometry method was developed and validated for the assay of clopidogrel in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective [M+H](+) ions, m/z 322/212 for clopidogrel and m/z 264/154 for the internal standard. The assay exhibited a linear dynamic range of 5-6000 pg/mL for clopidogrel in human plasma.
View Article and Find Full Text PDF