Publications by authors named "Ramachandran Prabhakar"

Article Synopsis
  • This observational study explores the use of x-ray images of chemoembolisation deposits for real-time image-guided radiation therapy in patients with hepatocellular carcinoma.
  • The study involves 50 patients who have undergone or will undergo stereotactic ablative radiation therapy, analyzing their imaging data and developing a deep learning method for motion tracking.
  • The goal is to demonstrate that the deep learning software can accurately track the placement of chemoembolisation materials, improving targeting accuracy without needing invasive procedures for fiducial markers.
View Article and Find Full Text PDF

Introduction: Segmentation and analysis of organs at risks (OARs) and tumor volumes are integral concepts in the development of radiotherapy treatment plans and prediction of patients' treatment outcomes.

Aims: To develop a research tool, PAHPhysRAD, that can be used to semi- and fully automate segmentation of OARs. In addition, the proposed software seeks to extract 3214 radiomic features from tumor volumes and user-specified dose-volume parameters.

View Article and Find Full Text PDF

The Leksell Gamma Knife® Perfexion™ and Icon™ have a unique geometry, containing 192 Co sources with collimation for field sizes of 4 mm, 8 mm, and 16 mm. 4 mm and 8 mm collimated fields lack lateral charged particle equilibrium, so accurate field output factors are essential. This study performs field output factor measurements for the microDiamond, microSilicon, and RAZOR™ Nano detectors.

View Article and Find Full Text PDF

Objectives: To investigate the impact of adding 68Ga-DOTATATE PET/MRI to standard MRI for target volume delineation in Gamma Knife® stereotactic radiosurgery (GKSRS) for meningioma.

Methods: Seventeen patients with 18 lesions undergoing GKSRS for WHO grade 1 meningioma were enrolled in a prospective study. All patients underwent pre-treatment 68Ga-DOTATATE PET/MRI examination in addition to standard procedures.

View Article and Find Full Text PDF

Radiation dosimeters play a crucial role in radiation oncology by accurately measuring radiation dose, ensuring precise and safe radiation therapy. This study presents the design and development of a low-cost printed circuit board (PCB) dosimeter and an integrated electrometer with sensitivity optimized for dose rates intended for use in megavoltage radiation therapy. The PCB dosimeter was designed in KiCad, and it uses a low-cost S5MC-13F general-purpose 1 kV 5A power diode as a radiation detector.

View Article and Find Full Text PDF

Automated medical image segmentation (MIS) using deep learning has traditionally relied on models built and trained from scratch, or at least fine-tuned on a target dataset. The Segment Anything Model (SAM) by Meta challenges this paradigm by providing zero-shot generalisation capabilities. This study aims to develop and compare methods for refining traditional U-Net segmentations by repurposing them for automated SAM prompting.

View Article and Find Full Text PDF

Purpose: Multiple survey results have identified a demand for improved motion management for liver cancer IGRT. Until now, real-time IGRT for liver has been the domain of dedicated and expensive cancer radiotherapy systems. The purpose of this study was to clinically implement and characterise the performance of a novel real-time 6 degree-of-freedom (DoF) IGRT system, Kilovoltage Intrafraction Monitoring (KIM) for liver SABR patients.

View Article and Find Full Text PDF

Purpose: Optimizers are widely utilized across various domains to enhance desired outcomes by either maximizing or minimizing objective functions. In the context of deep learning, they help to minimize the loss function and improve model's performance. This study aims to evaluate the accuracy of different optimizers employed for autosegmentation of non-small cell lung cancer (NSCLC) target volumes on thoracic computed tomography images utilized in oncology.

View Article and Find Full Text PDF

The patient setup technique currently in practice in most radiotherapy departments utilises on-couch cone-beam computed tomography (CBCT) imaging. Patients are positioned on the treatment couch using visual markers, followed by fine adjustments to the treatment couch position depending on the shift observed between the computed tomography (CT) image acquired for treatment planning and the CBCT image acquired immediately before commencing treatment. The field of view of CBCT images is limited to the size of the kV imager which leads to the acquisition of partial CBCT scans for lateralised tumors.

View Article and Find Full Text PDF

The quality of organ volume delineation significantly influences the efficacy of radiotherapy treatment for breast cancer patients. This study introduces a novel method for auto-segmentation of the breasts, lungs and heart. The proposed pipeline leverages a multi-class 3D U-Net with a pre-trained ResNet(2+1)D-18 encoder branch, cascaded with a 2D PatchGAN mask correction model for each class.

View Article and Find Full Text PDF

Aim: The aim of this study is to determine the variation in Hounsfield values with single and multi-slice methods using in-house software on fan-beam computed tomography (FCT), linear accelerator (linac) cone-beam computed tomography (CBCT), and Icon-CBCT datasets acquired using Gammex and advanced electron density (AED) phantoms.

Materials And Methods: The AED phantom was scanned on a Toshiba computed tomography (CT) scanner, five linac-based CBCT X-ray volumetric imaging systems, and Leksell Gamma Knife Icon. The variation between single and multi-slice methods was assessed by comparing scans acquired using Gammex and AED phantoms.

View Article and Find Full Text PDF

Aim: Current radiotherapy treatment techniques require a large amount of imaging data for treatment planning which demand significant clinician's time to segment target volume and organs at risk (OARs). In this study, we propose to use U-net-based architecture to segment OARs commonly encountered in lung cancer radiotherapy.

Materials And Methods: Four U-Net OAR models were generated and trained on 20 lung cancer patients' computed tomography (CT) datasets, with each trained for 100 epochs.

View Article and Find Full Text PDF

This paper aims to provide guidance and a framework for commissioning tests and tolerances for the ExacTrac Dynamic image-guided and surface-guided radiotherapy (SGRT) system. ExacTrac Dynamic includes a stereoscopic X-ray system, a structured light projector, stereoscopic cameras, thermal camera for SGRT, and has the capability to track breath holds and internal markers. The system provides fast and accurate image guidance and intrafraction guidance for stereotactic radiosurgery and stereotactic ablative radiotherapy.

View Article and Find Full Text PDF

Aim: The aim of this study was to compare the Exradin W2 scintillator, PTW microDiamond, IBA Razor Nano, and IBA Razor chamber detectors for small-field dose measurements and validate the measured data against the EGSnrc user code and observe the variation between daisy-chained and direct measurement methods for the above detectors.

Materials And Methods: The W2 scintillator, microDiamond, Razor Nano, and Razor chamber detectors were used to measure the in-plane and cross-plane profiles and the output factors (OFs) at 10 cm depth, and 90 source-to-surface distance for 6MV X-rays (Elekta Versa HD). The field sizes ranged from 0.

View Article and Find Full Text PDF

. To explore the efficacy of two different approaches to train a Fully Convolutional Neural Network (FCNN) with Graphical Processing Unit (GPU) memory limitations and investigate if pre-trained two-dimensional weights can be transferred into a three-dimensional model for the purpose of brain tumour segmentation..

View Article and Find Full Text PDF

Optically stimulated luminescence dosimetry is a relatively recent field of in-vivo dosimetry in clinical radiotherapy, developing over the last 20 years. As a pilot study, this paper presents a direct comparison between the sensitivity variance with use, stability of measurement and linearity of the current clinical standard AlO:C and a potential alternative, beryllium oxide. A set of ten optically stimulated luminescence dosimeters (OSLD), including five of each type, were used simultaneously and irradiated on a Versa HD linear accelerator.

View Article and Find Full Text PDF

With the increased use of X-ray imaging for patient alignment in external beam radiation therapy, particularly with cone-beam computed tomography (CBCT), the additional dose received by patients has become of greater consideration. In this study, we analysed the radiation dose from CBCT for clinical lung radiotherapy and assessed its relative contribution when combined with radiation treatment planning for a variety of lung radiotherapy techniques. The Monte Carlo simulation program ImpactMC was used to calculate the 3D dose delivered by a Varian TrueBeam linear accelerator to patients undergoing thorax CBCT imaging.

View Article and Find Full Text PDF

. The aim of this study was to assess the feasibility of the development and training of a deep learning object detection model for automating the assessment of fiducial marker migration and tracking of the prostate in radiotherapy patients..

View Article and Find Full Text PDF

Stereotactic Ablative Radiotherapy (SABR) remains one of the preferred treatment techniques for early-stage cancer. It can be extended to more treatment locales involving the sternum, scapula and spine. This work investigates SABR checks using Alanine and nanoDot dosimeter for three treatment sites, including sternum, spine and scapula.

View Article and Find Full Text PDF

Purpose: The aim of this study was to assess the suitability of using cone-beam computed tomography images (CBCTs) produced in a Leksell Gamma Knife (LGK) Icon system to generate electron density information for the convolution algorithm in Leksell GammaPlan (LGP) Treatment Planning System (TPS).

Materials And Methods: A retrospective set of 30 LGK treatment plans generated for patients with multiple metastases was selected in this study. Both CBCTs and fan-beam CTs were used to provide electron density data for the convolution algorithm.

View Article and Find Full Text PDF

Purpose: Fiducial marker seeds are often used as a surrogate to identify and track the positioning of prostate volume in the treatment of prostate cancer. Tracking the movement of prostate seeds aids in minimizing the prescription dose spillage outside the target volume to reduce normal tissue complications. In this study, You Only Look Once (YOLO) v2™ (MathWorks™) convolutional neural network was employed to train ground truth datasets and develop a program in MATLAB that can visualize and detect the seeds on projection images obtained from kilovoltage (kV) X-ray volume imaging (XVI) panel (Elekta™).

View Article and Find Full Text PDF

Dose to the contralateral breast (CLB) from radiotherapy treatment has the potential to induce secondary breast cancer. Electronic tissue compensation (eComp) for breast cancer patients is one of the alternative methods to conventional 3D-conformal radiotherapy that eliminates the use of wedges. Several studies have investigated dose to the CLB using tangential fields involving wedges, intensity-modulated radiation therapy and volumetric modulated arc radiation therapy and various other techniques via treatment planning system calculations, Monte Carlo methods and phantoms.

View Article and Find Full Text PDF

Geometric distortions in magnetic resonance can introduce significant uncertainties into applications such as radiotherapy treatment planning and need to be assessed as part of a comprehensive quality assurance program. We report the design, fabrication, and imaging of a custom 3D printed unibody MR distortion phantom along with quantitative image analysis.: The internal cavity of the phantom is an orthogonal three-dimensional planar lattice, composed of 3 mm diameter rods spaced equidistantly at a 20 mm centre-centre offset repeating along the X, Y, and Z axes.

View Article and Find Full Text PDF

Purpose: To assess and compare the dosimetric parameters obtained between three-dimensional conformal radiotherapy (3DCRT), three-dimensional field-in-field (3DFIF), 5-field intensity-modulated radiotherapy (IMRT MF5), tangential IMRT (tIMRT), tangential volumetric modulated arc therapy (tVMAT), electronic tissue compensation (Ecomp), and Hybrid treatment plans.

Materials And Methods: Thirty planning computed tomography datasets obtained from patients previously treated with whole breast radiation therapy (WBRT) were utilized in this study. Treatment plans were created for 3DCRT, 3DFIF, IMRT MF5, tIMRT, tVMAT, Ecomp, and Hybrid techniques using Eclipse Treatment Planning System (version 13.

View Article and Find Full Text PDF

Electron applicator cutouts for radiation therapy electron beam shaping are typically cast from Low Melting Point Alloys (LMPA), such as cerrobend. In this work, we describe the Monte Carlo modelling of novel 3D printed cutouts based on tungsten carbide powder and the resulting dose profiles subject to Elekta Agility electron beams. Cerrobend cutouts were also modelled using the Monte Carlo code EGSnrc.

View Article and Find Full Text PDF