Introduction: Chewing has been reported to enhance cognitive function through the increase in cerebral blood flow. However, the mechanisms linking cerebral blood flow increase to metabolic changes in the brain affecting cognition remain unclear. We hypothesized that glutathione (GSH) plays a pivotal role in these mechanisms.
View Article and Find Full Text PDFThe HEALthy Brain and Child Development (HBCD) Study, a multi-site prospective longitudinal cohort study, will examine human brain, cognitive, behavioral, social, and emotional development beginning prenatally and planned through early childhood. The acquisition of multimodal magnetic resonance-based brain development data is central to the study's core protocol. However, application of Magnetic Resonance Imaging (MRI) methods in this population is complicated by technical challenges and difficulties of imaging in early life.
View Article and Find Full Text PDFBackground: Glutathione (GSH) is a crucial antioxidant in the human brain. Although proton magnetic resonance spectroscopy using the Mescher-Garwood point-resolved spectroscopy sequence is highly recommended, limited literature has measured cortical GSH using this method in major psychiatric disorders.
Methods: By combining magnetic resonance spectroscopy and resting-state functional magnetic resonance imaging, we quantified brain GSH and glutamate in the medial prefrontal cortex and precuneus and explored relationships between GSH levels and intrinsic neuronal activity as well as clinical symptoms among healthy control (HC) participants (n = 30), people with major depressive disorder (MDD) (n = 28), and people with obsessive-compulsive disorder (OCD) (n = 28).
A recurring issue in functional neuroimaging is how to link task-driven haemodynamic blood oxygen level dependent functional MRI (BOLD-fMRI) responses to underlying neurochemistry at the synaptic level. Glutamate and γ-aminobutyric acid (GABA), the major excitatory and inhibitory neurotransmitters respectively, are typically measured with MRS sequences separately from fMRI, in the absence of a task. The present study aims to resolve this disconnect, developing acquisition and processing techniques to simultaneously assess GABA, glutamate and glutamine (Glx) and BOLD in relation to a cognitive task, at 3 T.
View Article and Find Full Text PDFFunctional magnetic resonance spectroscopy (fMRS) of GABA at 3 T poses additional challenges compared with fMRS of other metabolites because of the difficulties of measuring GABA levels; GABA is present in the brain at relatively low concentrations, and its signal is overlapped by higher concentration metabolites. Using 7 T fMRS, GABA levels have been shown to decrease specifically during motor learning (and not during a control task). Though the use of 7 T is appealing, access is limited.
View Article and Find Full Text PDFImportance: Major depressive disorder (MDD) is one of the most prevalent illnesses worldwide. Perturbations of the major inhibitory and excitatory neurotransmitters, γ-aminobutyric acid (GABA) and glutamate (Glu), respectively, as well as Glx (Glu or glutamine [Gln]) have been extensively reported in a multitude of brain areas of individuals with depression, but few studies have examined changes in Gln, the metabolic counterpart of synaptic Glu.
Objective: To investigate changes in GABA, Glx, Glu, and Gln levels in a voxel in the left dorsolateral prefrontal cortex of participants with no, past, and current MDD using proton magnetic resonance spectroscopy (1H-MRS).
Purpose: Heating of gradient coils and passive shim components is a common cause of instability in the B field, especially when gradient intensive sequences are used. The aim of the study was to set a benchmark for typical drift encountered during MR spectroscopy (MRS) to assess the need for real-time field-frequency locking on MRI scanners by comparing field drift data from a large number of sites.
Method: A standardized protocol was developed for 80 participating sites using 99 3T MR scanners from 3 major vendors.
Background The hardware and software differences between MR vendors and individual sites influence the quantification of MR spectroscopy data. An analysis of a large data set may help to better understand sources of the total variance in quantified metabolite levels. Purpose To compare multisite quantitative brain MR spectroscopy data acquired in healthy participants at 26 sites by using the vendor-supplied single-voxel point-resolved spectroscopy (PRESS) sequence.
View Article and Find Full Text PDFReducing the echo time of magnetic resonance spectroscopy experiments is appealing because it increases the available signal and reduces J-evolution of coupled metabolites. In this manuscript a novel sequence, referred to as Ultrashort echo TimE, SPin ECho, full Intensity Acquired Localized (UTE-SPECIAL), is described which is able to achieve ultrashort echo times (4 ms) on a standard clinical 3 T MR system while recovering the entirety of the available magnetization. UTE-SPECIAL obtains full 3D spatial localization through a 2D adiabatic inversion pulse which is cycled "on" and "off" every other repetition, in combination with a slice-selective excitation pulse.
View Article and Find Full Text PDFConventional proton MRS has been successfully utilized to noninvasively assess tissue biochemistry in conditions that result in large changes in metabolite levels. For more challenging applications, namely, in conditions which result in subtle metabolite changes, the limitations of vendor-provided MRS protocols are increasingly recognized, especially when used at high fields (≥3 T) where chemical shift displacement errors, B and B inhomogeneities and limitations in the transmit B field become prominent. To overcome the limitations of conventional MRS protocols at 3 and 7 T, the use of advanced MRS methodology, including pulse sequences and adjustment procedures, is recommended.
View Article and Find Full Text PDFThe semi-adiabatic localization by adiabatic selective refocusing (sLASER) sequence provides single-shot full intensity signal with clean localization and minimal chemical shift displacement error and was recommended by the international MRS Consensus Group as the preferred localization sequence at high- and ultra-high fields. Across-vendor standardization of the sLASER sequence at 3 tesla has been challenging due to the B requirements of the adiabatic inversion pulses and maximum B limitations on some platforms. The aims of this study were to design a short-echo sLASER sequence that can be executed within a B limit of 15 μT by taking advantage of gradient-modulated RF pulses, to implement it on three major platforms and to evaluate the between-vendor reproducibility of its perfomance with phantoms and in vivo.
View Article and Find Full Text PDFPurpose: To introduce a robust methodology for fast H MRSI of the brain at 3T with improved SNR and reduced phase-related artifacts.
Method: An accelerated acquisition scheme using echo-planar spectroscopic imaging (EPSI) was combined with the overdiscrete reconstruction framework. This approach enables the interleaved acquisition of a water reference scan at each phase encoding step, maximizing its correlation with the water-suppressed measurement.
Purpose: Investigate the possibility of measuring changes in glutathione (GSH) concentration using the MRS PRESS and MEGA-PRESS sequences by tracking the natural oxidation of GSH, and to examine the accuracy of the two methods.
Methods: 122 GSH edited MEGA-PRESS and PRESS acquisitions were acquired on a "braino" based phantom +3.0 mM GSH during a period of 11 days.
Proton MRS ( H MRS) provides noninvasive, quantitative metabolite profiles of tissue and has been shown to aid the clinical management of several brain diseases. Although most modern clinical MR scanners support MRS capabilities, routine use is largely restricted to specialized centers with good access to MR research support. Widespread adoption has been slow for several reasons, and technical challenges toward obtaining reliable good-quality results have been identified as a contributing factor.
View Article and Find Full Text PDFAccurate and reliable quantification of brain metabolites measured in vivo using H magnetic resonance spectroscopy (MRS) is a topic of continued interest. Aside from differences in the basic approach to quantification, the quantification of metabolite data acquired at different sites and on different platforms poses an additional methodological challenge. In this study, spectrally edited γ-aminobutyric acid (GABA) MRS data were analyzed and GABA levels were quantified relative to an internal tissue water reference.
View Article and Find Full Text PDFSpectral editing allows direct measurement of low-concentration metabolites, such as GABA, glutathione (GSH) and lactate (Lac), relevant for understanding brain (patho)physiology. The most widely used spectral editing technique is MEGA-PRESS, which has been diversely implemented across research sites and vendors, resulting in variations in the final resolved edited signal. In this paper, we describe an effort to develop a new universal MEGA-PRESS sequence with HERMES functionality for the major MR vendor platforms with standardized RF pulse shapes, durations, amplitudes and timings.
View Article and Find Full Text PDFGlutamate is the most abundant excitatory neurotransmitter in the human brain, but in vivo imaging of acute fluctuations in glutamatergic levels has not been well established. The purpose of this study was to examine acute changes in glutamate after stimulation with N-acetylcysteine (NAC) using a simultaneous positron emission tomography/magnetic resonance spectroscopy (PET/MRS) approach. Ten healthy adult males were examined in two scanning sessions, and 5g NAC was administered 1 h prior to one of the scan sessions.
View Article and Find Full Text PDFMR spectroscopic imaging (MRSI) at ultra-high field (≥7 T) benefits from improved sensitivity that allows the detection of low-concentration metabolites in the brain. However, optimized acquisition techniques are required to overcome inherent limitations of MRSI at ultra-high field. This work describes an optimized method for fast high-resolution H-MRSI of the brain at 7 T.
View Article and Find Full Text PDFMagnetic resonance spectroscopy (MRS) is the only biomedical imaging method that can noninvasively detect endogenous signals from the neurotransmitter γ-aminobutyric acid (GABA) in the human brain. Its increasing popularity has been aided by improvements in scanner hardware and acquisition methodology, as well as by broader access to pulse sequences that can selectively detect GABA, in particular J-difference spectral editing sequences. Nevertheless, implementations of GABA-edited MRS remain diverse across research sites, making comparisons between studies challenging.
View Article and Find Full Text PDFPurpose: The most common γ-aminobutyric-acid (GABA) editing approach, MEGA-PRESS, uses J-editing to measure GABA distinct from larger overlapping metabolites, but suffers contamination from coedited macromolecules (MMs) comprising 40 to 60% of the observed signal. MEGA-SPECIAL is an alternative method with better MM suppression, but is not widely used primarily because of its relatively poor spatial localization. Our goal was to develop an improved MM-suppressed GABA editing sequence at 3 Tesla.
View Article and Find Full Text PDFPurpose: The reproducibility of the MEGA-PRESS (MEshcher-GArwood Point RESolved Spectroscopy) MR spectroscopy sequence for the measurement of gamma- aminobutyric acid (GABA) is addressed, focusing on optimizing the number of repetitions at two voxel locations in the human brain and associated possibilities in analysis tools.
Materials And Methods: Two 20-min MEGA-PRESS acquisitions were run (echo time = 68 ms, repetition time = 1800 ms, repetitions = 328): one from a 21 mL volume in the anterior cingulate cortex (ACC) and one from a 22 mL volume in the left Broca's area in 21 healthy male volunteers (age 32 years ± 6[SD]). Subjects were scanned twice with identical protocols, 1 week apart.
Background: The majority of WHO grades II and III gliomas harbor a missense mutation in the metabolic gene isocitrate dehydrogenase (IDH) and accumulate the metabolite R-2-hydroxyglutarate (R-2HG). Prior studies showed that this metabolite can be detected in vivo using proton magnetic-resonance spectroscopy (MRS), but the sensitivity of this methodology and its clinical implications are unknown.
Methods: We developed an MR imaging protocol to integrate 2HG-MRS into routine clinical glioma imaging and examined its performance in 89 consecutive glioma patients.
Magnetic resonance spectroscopy (MRS) from voxels placed in the left anterior cingulate cortex (ACC) was measured from 14 boys with Autism Spectrum Disorder (ASD) and 24 gender and age-matched typically developing (TD) control group. Our main aims were to compare the concentration of γ-aminobutyric acid (GABA) between the two groups, and to investigate the relationship between brain metabolites and autism symptom severity in the ASD group. We did find a significant negative correlation in the ASD group between Autism Spectrum Screening Questionnaire (ASSQ) and GABA+/Cr, which may imply that severity of symptoms in ASD is associated with differences in the level of GABA in the brain, supporting the excitatory/inhibitory (E/I) imbalance theory.
View Article and Find Full Text PDF