Previous studies have linked peripheral microvascular dysfunction measured by arterial tonometry to high residual risk in on-statin patients. Digital thermal monitoring (DTM) of microvascular function is a new and simplified technique based on fingertip temperature measurements that has been correlated with the burden of atherosclerosis and its risk factors. Here, we report analyses of DTM data from two large US registries: Registry-I (6,084 cases) and Registry-II (1,021 cases) across 49 US outpatient clinics.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2018
An intra-atrial pump (IAP) was proposed that would be affixed to the atrial septum to support the compromised left ventricle (LV) without harming the ventricular tissue in patients with early-stage heart failure. The IAP is designed to operate in parallel with the LV, drawing blood from the left atrium and unloading the LV. In previous hydraulic studies, different blade geometries were tested for the IAP; however, it is important to know how the blade geometry affects the IAP's hemodynamic performance in the human cardiovascular system.
View Article and Find Full Text PDFLeft ventricular assist devices (LVADs) are increasingly used to treat heart failure patients. These devices' impeller blades and diffuser vanes must be designed for hydraulic performance and hemocompatibility. The traditional design method, applying mean-line theory, is not applicable to the design of small-scale pumps such as miniature LVADs.
View Article and Find Full Text PDFPurpose: A minimally invasive, partial-assist, intra-atrial blood pump has been proposed, which would unload the left ventricle with a flow path from the left atrium to the arterial system. Flow modulation is a common strategy for ensuring washout in the pump, but it can increase power consumption because it is typically achieved through motor-speed variation. However, if a pump's performance curve had the proper gradient, flow modulation could be realized passively.
View Article and Find Full Text PDFRationale And Objectives: Small metallic stents are increasingly used in the treatment of cerebral aneurysms and for revascularization in ischemic strokes. Realistic three-dimensional datasets of a stent were obtained by using three x-ray-based imaging methods in current clinical use. Multislice-CT (MS-CT), C-arm flat detector-CT (C-arm CT, ACT), and flat panel-CT (FP-CT) were compared with high-resolution laboratory MicroCT scans that served as a reference standard.
View Article and Find Full Text PDFBoth structural and functional evaluations of the endothelium exist in order to diagnose cardiovascular disease (CVD) in its asymptomatic stages. Vascular reactivity, a functional evaluation of the endothelium in response to factors such as occlusion, cold, and stress, in addition to plasma markers, is the most widely accepted test and has been found to be a better predictor of the health of the endothelium than structural assessment tools such as coronary calcium scores or carotid intima-media thickness. Among the vascular reactivity assessment techniques available, digital thermal monitoring (DTM) is a noninvasive technique that measures the recovery of fingertip temperature after 2-5 min of brachial occlusion.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
April 2010
Previous research on the effects of intracranial stents on arterial hemodynamics has involved computational hemodynamics (CHD) simulations applied to artificially generated stent models. In this study, accurate geometric reconstructions of in-vitro (PTFE tube) and ex-vivo (canine artery) deployed stents based on ultra-high resolution MicroCT imaging were used. The primary goal was to compare the hemodynamic effects of deployment in these two different models and to identify flow perturbations due to deployment anomalies such as stent malapposition and strut prolapse, important adverse mechanics occurring in clinical practice, but not considered in studies using idealized stent models.
View Article and Find Full Text PDFLittle is known about flow patterns in ventricles supported by continuous flow left ventricular assist devices (LVADs), and valuable information can be obtained with simple flow visualization experiments. We describe the application of several experimental techniques for the in vitro study of ventricular flow patterns (e.g.
View Article and Find Full Text PDFThe strength and direction of blood flow into and within a cerebral aneurysm are important issues in developing effective interventional strategies to stabilize the aneurysm. We tested the hypothesis that there are significant major hemodynamic features that are common to many aneurysm flows of the type studied here. This was investigated by performing computational fluid dynamic simulations of flow near 7 cerebral aneurysms using geometrical data obtained from clinical CT scans.
View Article and Find Full Text PDFDigital thermal monitoring (DTM) of vascular function during cuff-occlusive reactive hyperemia relies on the premise that changes in fingertip temperature during and after an ischemic stimulus reflect changes in blood flow. To determine its utility in individuals with and without known coronary heart disease (CHD), 133 consecutive individuals (age 54 +/- 10 years, 50% male, 19 with known CHD) underwent DTM during and after 2 minutes of supra-systolic arm cuff inflation. Fingertip temperatures of the occluded and non-occluded fingertips were measured simultaneously.
View Article and Find Full Text PDFWe developed a mock circulatory loop and used mathematical modeling to test the in vitro performance of a physiologic flow control system for a total artificial heart (TAH). The TAH was constructed from two continuous flow pumps. The objective of the control system was to maintain loop flow constant in response to changes in outflow resistance of either pump.
View Article and Find Full Text PDFThe in vitro sensitivity of continuous flow pumps to preload and afterload pressure has been well characterized. We compared flow in the Jarvik 2000 and HeartMate II continuous flow left ventricular assist devices (LVADs) at different inflow and outflow pressures and different pump speeds. This allowed us to measure the impact of a changing inflow pressure on the pump flow rate at different speeds but against a constant afterload.
View Article and Find Full Text PDFContinuous flow pumps are increasingly used to treat severe heart failure. These pumps alter flow physiology by lowering pulsatility in the arterial circulation. In patients with peripheral stenosis, continuous flow pumps may lead to thrombosis of peripheral vessels, possibly predisposing to vascular thrombosis in areas of non-flow-limiting stenosis.
View Article and Find Full Text PDF