Publications by authors named "Ralf Sodian"

The primary objective of this study was to evaluate the initial experience in Germany with the Meril Myval™ (MM) transcatheter heart valve (THV) system for the treatment of severe symptomatic aortic valve stenosis. The MM THV is a novel balloon-expandable valve with an expanded sizing matrix. Contemporary patients undergoing TAVI with the established Edwards Sapien™ (ES) THV served as the comparator group.

View Article and Find Full Text PDF

Background:  Bioprosthetic stentless aortic valves may degenerate over time and will require replacement. This study aimed to evaluate early- and mid-term outcomes after isolated surgical redo aortic valve replacement (redo-SAVR) and transcatheter valve-in-valve implantation (TAVI-VIV) for degenerated stentless Freestyle bioprostheses.

Methods:  We reviewed records of 56 patients at a single center.

View Article and Find Full Text PDF

Objectives: Degeneration of mitral prostheses/rings may be treated by redo surgery, and, recently, by transcatheter valve-in-valve/ring implantation. This multicenter registry presents results of transcatheter valve-in-valve and repeat surgery for prostheses/rings degeneration.

Methods: Data provided by 10 German heart centers underwent propensity score-matched retrospective analysis.

View Article and Find Full Text PDF

A 73-year-old patient who underwent an emergency coronary bypass surgery in our institution and who required postoperative extracorporeal membrane oxygenation support in December 2019 presented in August 2020 with a rapidly growing subxiphoidal, pulsating swelling. A computed tomography scan revealed a massive mediastinal pseudoaneurysm originating from an 8-mm Dacron graft that was sutured to the ascending aorta during the index surgery for arterial extracorporeal membrane oxygenation cannulation. Due to the location and extent of the pseudoaneurysm, an open surgical revision was deemed high risk.

View Article and Find Full Text PDF

 Although surgical closure of ventricular septal defect (VSD) is the gold standard treatment, patients are subjected to deterioration in the following decades. We will present here the first case in literature surviving 60 years after surgical VSD closure with a residual VSD and presenting again for surgery.  A 68-year-old male patient who underwent surgical closure of a perimembranous VSD in Berlin in 1959.

View Article and Find Full Text PDF

The objective of this study was to evaluate the use of the generation of 3D models and 3D prints of complex cases for physicians at the example of an intricate left ventricular outflow tract obstruction (LVOTO). LVOTO is a known complication of mitral valve surgery. A 38-year-old female patient with increasing dyspnoea after mitral valve replacement was referred to our centre.

View Article and Find Full Text PDF

Mitral valve regurgitation is one of the most common heart valve diseases and mitral valve repair is the favored therapy, in which a part of the mitral valve is resected. To improve preoperative planning of this challenging surgery, patient-specific mitral valve replicas have been developed on which the repair can be simulated. However, there is no possibility yet to transfer the planning from the replica to the surgery of the patient.

View Article and Find Full Text PDF
Article Synopsis
  • Three-dimensional echocardiographic (3DE) and cardiac computed tomographic (CCT) imaging are important tools in cardiology, but traditional 2D monitors limit their visualization capabilities.
  • This study aimed to explore the potential of virtual reality (VR) for creating true 3D models from 3DE and CCT data, assessing measurement accuracy and environmental usability.
  • Results showed that VR significantly reduced measurement variability (up to 40%), decreased the time required for measurements (up to 39%), and improved user confidence in diagnostic assessments compared to conventional software.
View Article and Find Full Text PDF

Thoracic endovascular aortic repair (TEVAR) for aortic pathologies requires sufficient landing zone of ideally more than 25 mm for safe anchoring of the stent-graft and prevention of endoleaks. In the aortic arch and at the thoracoabdominal transition, landing zone length is usually limited by the offspring of the major aortic side-branches. Exact deployment of the stent-graft to effectively use the whole length of the landing zone and to prevent occlusion of one of the side-branches is key to successful TEVAR.

View Article and Find Full Text PDF

We report on a case of a 57-year-old male patient, who underwent full root replacement in 2005 and now presented with high grade aortic insufficiency. On admission, the patient underwent a computed tomography scan which demonstrated interstitial infiltration in the left lung, highly suspicious for a COVID-19 infection that could not be confirmed by reverse transcription polymerase chain reaction (RT-PCR) testing. As there usually is a delay between infection and positive RT-PCR test results, the initial decision was to perform additional testing.

View Article and Find Full Text PDF

Objectives: Cell sources for cardiovascular tissue engineering (TE) are scant. However, the need for an ideal TE cardiovascular implant persists. We investigated the cardiotomy reservoir (CR) as a potential cell source that is more accessible and less ethically problematic.

View Article and Find Full Text PDF

 Obesity is a limiting factor for the use of bilateral internal mammary arteries (BIMAs). Therefore, we assessed the safety of their use in different degrees of obesity.  We studied two groups of patients with obesity using propensity matching.

View Article and Find Full Text PDF

Aims: While TAVI is the treatment of choice in patients with aortic stenosis considered inoperable or at high risk, interventional replacement of the mitral valve is still in the preclinical or early clinical phase. Our aim was to report on the first transcatheter double valve replacement into native valves from a transapical access.

Methods And Results: A 67-year-old, highly symptomatic female patient considered inoperable due to severe calcification of the mitral annulus and comorbidities was scheduled for transcatheter double valve replacement by the local Heart Team.

View Article and Find Full Text PDF

Background: The use of bilateral internal mammary arteries (BIMA) is limited worldwide, especially in patients with chronic obstructive pulmonary disease (COPD). Thus, we assessed the safety of the use of BIMA in COPD patients.

Methods: From cohorts of 8846 patients operated on at our center for primary isolated multi-vessel coronary bypass operations between 2002 and 2012, we studied two propensity-matched groups of patients with COPD who received either single internal mammary artery and saphenous vein grafts (SIMA group: 137 patients) or exclusively BIMA (BIMA group: 137 patients).

View Article and Find Full Text PDF

Objectives: End-stage renal disease patients on regular haemodialysis are at higher risk of calcification. Therefore, many surgeons have concerns regarding the implantation of bioprostheses in such patients. The haemodynamic advantages of stentless aortic bioprostheses support their use; however, these have not been studied yet in end-stage renal disease patients.

View Article and Find Full Text PDF

Background: In cardiac surgery profuse or persistent sternal bleeding after sternotomy is routinely controlled with bone wax. However, bone wax should be avoided, especially in high-risk patients for nonunion of the sternum and infections. Purpose of this study was to evaluate an alternative technique to control bleeding after medium sternotomy using a plant based absorbable polysaccharide hemostat.

View Article and Find Full Text PDF

Objectives: In individual cases, routine preoperative imaging might not be sufficient for optimal planning of cardiovascular procedures. Three-dimensional printing (3D), a widely used technique to build life-like replicas of anatomical structures that has proven value in different medical disciplines, might overcome these shortcomings. However, data on 3D printing in cardiovascular medicine are limited to single reports.

View Article and Find Full Text PDF

Atrioventricular (AV) disruption is a rare but fatal complication after prosthetic mitral valve replacement. Surgical management is controversial and ranges from epicardial tissue sealing to open repair using autologous or xenogenic patch techniques to autotransplantation of the heart. We report the successful repair of an AV disruption Type I using an extracorporeal life support (ECLS) system for effective ventricular unloading followed by epicardial patch closure.

View Article and Find Full Text PDF

Purpose: In this study, we show the use of three-dimensional printing models for preoperative planning of surgery for patients with complex aortic arch anomalies.

Description: A 70-year-old man with an extensively arteriosclerotic aneurysm reaching from the ascending aorta to the descending aorta was referred to our center for complete aortic arch replacement. We visualized and reconstructed computed tomography data of the patient and fabricated a flexible three-dimensional model of the aortic arch including the aneurysm.

View Article and Find Full Text PDF

Background: The management of type A intramural hematoma (IMH) is controversial. Although most Western countries still recommend immediate surgical repair, some centers in Asia have shown good results recently with medical treatment alone. Here, we present a case of type A IMH which was discovered during the operation to be a thrombosed type A dissection.

View Article and Find Full Text PDF

In this retrospective study, we investigated the impact of preconditioning of the right ventricle with the calcium sensitizer levosimendan immediately before left ventricular assist device (LVAD) implantation on outcome and survival. Nine consecutive LVAD patients (seven suffering from dilative cardiomyopathy and two from ischemic cardiomyopathy) with echocardiographic and invasive evidence of right heart insufficiency received levosimendan with 0.1 μg/kg body weight/min for 24 h before implantation of the assist device (seven HeartWare and two Jarvik 2000).

View Article and Find Full Text PDF

A 65-year-old male patient was considered inoperable by conventional means for a previous triple coronary artery bypass grafting with a patent in situ right internal mammary artery graft to the left anterior descending artery crossing the thorax at midline directly behind the sternum. Transcatheter aortic valve implantation failed due to loss of the prosthetic device in the left ventricular outflow tract. Mandatory conversion was accomplished by an inferior partial T-shape sternotomy and extracorporeal circulation draining from the right atrium and feeding into the right femoral artery.

View Article and Find Full Text PDF