Publications by authors named "Ralf Josephs"

A reference material for virus-like particles traceable to the International System of Units (Système International d'Unités - the SI) is reported. The material addresses the need for developing reference standards to benchmark virus-like gene delivery systems and help harmonize measurement approaches for characterization and testing. The material is a major component of synthetic polypeptide virus-like particles produced by the state-of-the-art synthetic and analytical chemistry methods used to generate gene delivery systems.

View Article and Find Full Text PDF

Oxytocin (OXT) is an important peptide that is mainly used as a therapeutic drug to induce labor or strengthen uterine contractions, or to control bleeding after childbirth. OXT has also been reported as a biomarker linked to emotion, and as a potential biomarker for cancer diagnosis. The accurate purity characterization of OXT calibrators is critical for quality control of pharmaceuticals and the development of reference measurement systems for this analyte in laboratory medicine.

View Article and Find Full Text PDF

The contamination of food and feed by mycotoxins, Aflatoxin B (AfB) being one of the most prominent examples, is of imminent concern to many countries. Regulatory limits for mycotoxins have been implemented, and these need to be supported by a sound measurement infrastructure for mycotoxin analysis in order to enforce and verify products, protect populations, and avoid technical barriers to trade in food stuffs. A Capability Building and Knowledge Transfer program on Metrology for Safe Food and Feed in Developing Economies was started at the International Bureau of Weights and Measures to allow National Metrology Institutes or Designated Institutes to work together to strengthen their national mycotoxin metrology infrastructure.

View Article and Find Full Text PDF

Peptides are an increasingly important group of biomarkers and pharmaceuticals. The accurate purity characterization of peptide calibrators is critical for the development of reference measurement systems for laboratory medicine and quality control of pharmaceuticals. The peptides used for these purposes are increasingly produced through peptide synthesis.

View Article and Find Full Text PDF

Background: Assessment of endogenous insulin secretion by measuring C-peptide concentrations is widely accepted. Recent studies have shown that preservation of even small amounts of endogenous C-peptide production in patients with type 1 diabetes reduces risks for diabetic complications. Harmonization of C-peptide results will facilitate comparison of data from different research studies and later among clinical laboratory results at different sites using different assay methods.

View Article and Find Full Text PDF

In metrology institutes, the state-of-the-art for purity analysis of peptides/proteins mainly addresses short and unfolded peptides. Important developments are anticipated for the characterization of nonlinear peptides or proteins. Hepcidin 1-25 is an interesting model system because this small protein contains four disulfide bridges with a particular connectivity that is difficult to reproduce and could induce a bias in quantification.

View Article and Find Full Text PDF

A normal phase-liquid chromatography-hybrid tandem mass spectrometry (NP-LC-MS/MS) method utilizing atmospheric pressure photoionization (APPI) without dopant has been developed and implemented for the simultaneous determination of several estrogenic steroid hormones. The combination of both NP-LC and APPI-MS/MS tolerates the use of solvents that have the advantages of being self-doping for APPI and, at the same time, inhibit the in situ formation of estrogen dimers as frequently observed for conventional reversed phase (RP)-LC methods. The NP-LC-APPI-MS/MS method has been validated in-house, and its performance characteristics (linearity, repeatability, limits of detection, etc.

View Article and Find Full Text PDF

A mass balance method is described for determining the mass fraction of the main component of a high purity organic material. The resulting assigned value is established to be traceable to the SI and can be determined with a small associated measurement uncertainty. Pure organic materials with values and uncertainties determined in this way are necessary as primary calibrators of reference measurement systems in order to underpin the metrological traceability of routine measurement results.

View Article and Find Full Text PDF

A high performance liquid chromatography-hybrid tandem mass spectrometry (LC-MS(n)) method utilising electrospray ionisation has been developed and implemented for the simultaneous determination of several cardiac glycosides (CGs) as well as their corresponding aglycones formed by and extracted from herbaceous plants of the genus Digitalis. The method has been validated in-house and its performance characteristics (linearity, repeatability, limits of detection, etc.) were assessed for use in the quantification of CGs and their corresponding aglycones.

View Article and Find Full Text PDF

This paper presents results from the European Commission-funded project Doncalibrant, the objective of which was to produce calibrators with certified mass fractions of the Fusarium toxins deoxynivalenol (DON), 3-acetyldeoxynivalenol (3-Ac-DON), 15-acetyldeoxynivalenol (15-Ac-DON), and nivalenol (NIV), in acetonitrile. The calibrators, available in ampoules, were sufficiently homogeneous, with between-bottle variations (s (bb)) of less than 2%. Long-term stability studies performed at four different temperatures between -18 and 40 degrees C revealed no significant negative trends (at a confidence level of 95%).

View Article and Find Full Text PDF

Thirteen European laboratories experienced in the analysis of mycotoxins participated in an intercomparison study within a European Commission-funded project. Goals of the study were to check the fitness for purpose of a small batch of gravimetrically prepared calibrants; to compare individually prepared calibrants with common calibrants; to check the feasibility of toxin mixtures as calibrant solutions; and to give recommendations on the production of future certified reference materials (CRMs) with regard to the nature of the calibrant and the means of certification. Each laboratory received ampules of each common calibrant containing single toxins [solution containing either deoxynivalenol (DON), 3-acetyl-DON (3-Ac-DON), nivalenol (NIV), or 15-acetyl-DON (15-Ac-DON)] and 3 ampules of toxin-mixture (solutions of DON + 3-Ac-DON + NIV in acetonitrile) of known concentrations (about 20 microg/mL).

View Article and Find Full Text PDF

The contamination of maize by fungi, especially by Fusarium species, is a worldwide problem. One of the most prevalent Fusarium mycotoxins frequently found on European maize is zearalenone (ZON), which has been implicated in a range of human and animal diseases. It shows remarkable estrogenic properties and can cause severe infertility problems in farm animals.

View Article and Find Full Text PDF

Several previous interlaboratory studies in the field of mycotoxin analysis have revealed considerable problems, apparent as high between-laboratory standard deviations, or rather non-comparable and non-traceable results. A major reason is lack of proper calibrants for external calibration. Public awareness of substances that mimic or interfere with the activity of natural hormones (endocrine disrupters) has led to increased interest in mycotoxins with estrogenic potential, e.

View Article and Find Full Text PDF

Analytical difficulty and the economic importance of controlling mycotoxin levels in food and feed led the Community Bureau of Reference (BCR) to prepare a series of certified reference materials (CRM) for various mycotoxins. Because of the wide acceptance of these CRM and the need to ensure the comparability and traceability of measurements in the future it is necessary to prepare and certify new batches of mycotoxin reference materials (RM). In the following text two different approaches for evaluation of the characterisation uncertainty of CRM will be compared using the certification of aflatoxin M(1) (AfM(1)) in milk powder as an example.

View Article and Find Full Text PDF

Commercially available solid zearalenone (ZON) to be used as a certified liquid calibrant (BCR-699) in a project funded by the European Commission within the Standard Measurement and Testing program was characterized and its purity determined. The degree of purity of the ZON was examined by UV spectrophotometer, liquid chromatography (LC) with diode array and fluorescence detection, 1H and 13C-NMR spectrometry, LC-mass spectrometry (LC/MS/MS), ion chromatography (IC), and differential scanning calorimetry (DSC). The diagrams obtained from DSC analysis and the UV spectrum showed no detectable impurities.

View Article and Find Full Text PDF

In the field of mycotoxin analysis, substantial problems shown by high between-laboratory standard deviations and noncomparable and nontraceable results have been caused by the lack of proper calibrants for external calibration. During a large-scale Standard Measurement and Testing project of the European Commission (EC) dealing with preparation and certification of reference materials for determination of the mycotoxin zearalenone (ZON) in maize, a ZON calibrant in acetonitrile was prepared and checked for purity, homogeneity, and stability. Before certification, on the basis of preparation, the calibrant was checked in a mini-interlaboratory study by UV spectrophotometric determination.

View Article and Find Full Text PDF