Publications by authors named "Rajeshri Pai"

The radiation protection programme is aimed at safe usage of radiation at workplace, ensuring minimum possible dose to radiation workers, patients and members of the public. Verification of the adequacy of protective measures in actual workplace is important, especially for diagnostic radiology facilities, as a substantial number of suspected overexposures are reported from these facilities. To address this issue, a study was conducted for mapping workplace radiation field at various locations in nine Diagnostic Radiology Facilities of two hospitals in India.

View Article and Find Full Text PDF

A Helical Tomotherapy (HT) Hi-Art II machine, Hi ART (TomoTherapy, Inc., Madison, WI, USA) was installed at our center in July 2007, and was the first machine in India. Image-guided HT is a new modality for delivering intensity modulated radiotherapy (IMRT).

View Article and Find Full Text PDF

Introduction: An ongoing institutional randomized clinical trial comparing three-dimensional conformal radiotherapy (3D CRT) and intensity-modulated radiotherapy (IMRT) provided us an opportunity to document and compare the time-manpower burden with these high-precision techniques in head and neck cancers.

Materials And Methods: A cohort of 20 consecutive patients in the ongoing trial was studied. The radiotherapy planning and delivery process was divided into well-defined steps and allocated human resource based on prevalent departmental practice.

View Article and Find Full Text PDF

Evaluation of dose distribution in a single plane (i.e., 2-dimensional [2D] planning) is simple and less resource-intensive than CT-based 3-dimensional radiotherapy (3DCRT) planning or intensity modulated radiotherapy (IMRT).

View Article and Find Full Text PDF

Rapid advancements in imaging technology have led to remarkable improvements in identification and localization of tumors, ushering the era of high-precision techniques in contemporary radiotherapy practice. However, uncertainties in patient set-up and organ motion during a course of fractionated radiotherapy can compromise precision of radiation therapy. Excellent accuracy has been achieved with invasive and non-invasive fixation systems for stereotactic radiotherapy.

View Article and Find Full Text PDF

Implementation of step-and-shoot intensity-modulated radiotherapy (IMRT) needs careful understanding of the accelerator start-up characteristic to ensure accurate and precise delivery of radiation dose to patient. The dosimetric characteristic of a Siemens Primus linear accelerator (LA) which delivers 6 and 18 MV x-rays at the dose rate of 300 and 500 monitor unit (MU) per minutes (min) respectively was studied under the condition of small MU ranging from 1 to 100. Dose monitor linearity was studied at different dose calibration parameter (D1_C0) by measuring ionization at 10 cm depth in a solid water phantom using a 0.

View Article and Find Full Text PDF