While measuring the relative gamma-to-electron conversion efficiencies of nanoparticles by incorporating them into plastic scintillator and comparing the number of counts in pulse height spectrum for gamma-rays from Am, WO and PbO nanocomposites offered lesser scintillation counts than their unloaded counterparts. As investigated, these nanoparticles absorb a major portion of outgoing electron energy such that exiting electrons turn incapable of scintillating the medium. This observation hints why only selected species of nanoparticles successfully enhance the gamma-counting efficiency of plastic scintillators.
View Article and Find Full Text PDFBiomonitoring wearable sensors based on two-dimensional nanomaterials have recently elicited keen research interest and potential for a new range of flexible nanoelectronic devices. Practical nanomaterial-based devices suited for real-world service, which exhibit first-rate performance while being an attractive accessory, are still distant. We report a multifunctional flexible wearable sensor fabricated using an ultrathin percolative layer of graphene nanosheets on laser-patterned gold circular interdigitated electrodes for monitoring vital human physiological parameters.
View Article and Find Full Text PDFFlexible strain sensors are emerging rapidly and overcoming the drawbacks of traditional strain sensors. However, many flexible sensors failed to balance the sensitivity, response time, and the desired sensing range. This work proposes a novel and cost-effective strain sensor which simultaneously achieved high sensitivity, fast response, and a good sensing range.
View Article and Find Full Text PDFThe discovery of stable two-dimensional (2D) materials has effectuated a rapid evolution of skin conformal sensors for health monitoring via epidermal electronics. Among the newly discovered 2D materials, MXene stands out as a solution-processable 2D material allowing easy fabrication of highly conductive thin films with the potential to realize flexible skin conformal sensors. Here, we present a successful demonstration of a TiC-MXene resistor as an extremely sensitive strain sensor in the form an ultrathin skin mountable temporary tattoo.
View Article and Find Full Text PDFIndian J Otolaryngol Head Neck Surg
November 2019
A new nasal sensor has been designed using Polyvinylidene fluoride (PVDF) film using its piezoelectric property to measure nasal patency. The aim of this study is to determine the intra- and intersession reliability of the new PVDF nasal sensor measurement of unilateral and combined nasal parameters in a group of healthy subjects. Two identical nasal sensors: for right nostril (RN) and left nostril (LN) were designed using piezoelectric natured PVDF films.
View Article and Find Full Text PDFWe report a novel strain sensor based on reduced graphene oxide (rGO) with palladium (Pd) nano-composite. The sensor was fabricated on the SS304 stainless-steel substrate using a screen-printing method. Graphene oxide was synthesized using a modified Hummer's method and reduced using a chemical route.
View Article and Find Full Text PDFThis paper presents development and performance assessment of an innovative and a highly potent graphene-electrolyte capacitive sensor (GECS) based on the supercapacitor model. Although graphene has been widely researched and adapted in supercapacitors as electrode material, this combination has not been applied in sensor technology. A low base capacitance, generally the impeding factor in capacitive sensors, is addressed by incorporating electric double layer capacitance in GECS, and a million-fold increase in base capacitance is achieved.
View Article and Find Full Text PDFIn patients with multiple myeloma and prostate cancer, extending the bisphosphonate dosing interval may help decrease medication-related morbidity without compromising therapeutic benefit.
View Article and Find Full Text PDFCommon carp (Cyprinus carpio) is a world-wide freshwater fish of eutrophic waters. C. carpio, have various reproductive traits, including early sexual maturity, that may make them excellent, large, realistic, aquaculture model species.
View Article and Find Full Text PDFCrash sensing and its assessment play a pivotal role in autonomous vehicles for preventing fatal casualties. Existing crash sensors are severely bottlenecked by sluggish response time, rigid mechanical components, and space constraints. Miniaturized sensors embedded with custom-tailored nanomaterials upholds potential to overcome these limitations.
View Article and Find Full Text PDFMicropump technology has evolved significantly in the last two decades and is finding a variety of applications ranging from μTAS (micro Total Analysis System) to drug delivery. However, the application area of the micropump is limited owing to: simple pumping mechanism, ease of handling, controlled (microliter to milliliter) delivery, continuous delivery, and accuracy in flow rate. Here, the author presents the design, development, characterization, and precision flow controlling of a DC-motor driven peristaltic pump for controlled drug delivery application.
View Article and Find Full Text PDFPeristaltic pumps were normally used to pump liquids in several chemical and biological applications. In the present study, a peristaltic pump was used to pressurize the chamber (positive as well negative pressures) using atmospheric air. In the present paper, we discuss the development and performance study of an automatic pressurization system to calibrate low range (millibar) pressure sensors.
View Article and Find Full Text PDFMicroneedle technology is one of the attractive methods in transdermal drug delivery. However, the clinical applications of this method are limited owing to: complexity in the preparation of multiple coating solutions, drug leakage while inserting the microneedles into the skin and the outer walls of the solid microneedle can hold limited quantity of drug. Here, the authors present the fabrication of an array of rectangular cup shaped silicon microneedles, which provide for reduced drug leakage resulting in improvement of efficiency of drug delivery and possibility of introducing multiple drugs.
View Article and Find Full Text PDFObjective: The aim of this study is to validate the applicability of the PolyVinyliDene Fluoride (PVDF) nasal sensor to assess the nasal airflow, in healthy subjects and patients with nasal obstruction and to correlate the results with the score of Visual Analogue Scale (VAS).
Methods: PVDF nasal sensor and VAS measurements were carried out in 50 subjects (25-healthy subjects and 25 patients). The VAS score of nasal obstruction and peak-to-peak amplitude (Vp-p) of nasal cycle measured by PVDF nasal sensors were analyzed for right nostril (RN) and left nostril (LN) in both the groups.
We report on the systematic comparative study of highly c-axis oriented and crystalline piezoelectric ZnO thin films deposited on four different flexible substrates for vibration sensing application. The flexible substrates employed for present experimental study were namely a metal alloy (Phynox), metal (aluminum), polyimide (Kapton), and polyester (Mylar). ZnO thin films were deposited by an RF reactive magnetron sputtering technique.
View Article and Find Full Text PDFJ Nanosci Nanotechnol
July 2014
Self catalytic growth of Indium Oxide (In2O3) nanowires (NWs) have been grown by resistive thermal evaporation of Indium (In) in the presence of oxygen without use of any additional metal catalyst. Nanowires growth took place at low substrate temperature of 370-420 degrees C at an applied current of 180-200 A to the evaporation boat. Morphology, microstructures, and compositional studies of the grown nanowires were performed by employing field emission scanning electron microscopy (FESEM), X-Ray diffraction (XRD), transmission electron microscopy (TEM), energy dispersive X-ray spectroscopy (EDS) and X-ray photoelectron spectroscopy (XPS) respectively.
View Article and Find Full Text PDFBackground: Deviated nasal septum (DNS) is one of the major causes of nasal obstruction. Polyvinylidene fluoride (PVDF) nasal sensor is the new technique developed to assess the nasal obstruction caused by DNS. This study evaluates the PVDF nasal sensor measurements in comparison with PEAK nasal inspiratory flow (PNIF) measurements and visual analog scale (VAS) of nasal obstruction.
View Article and Find Full Text PDFAllergy Rhinol (Providence)
February 2014
Noninvasive objective evaluation of nasal airflow is one of the important clinical aspects. The developed polyvinylidene fluoride (PVDF) sensor enables measurement of airflow through each side of the nose using its piezoelectric property. This study was designed to evaluate the diagnostic capability of the PVDF sensor in assessing the deviated nasal septum (DNS).
View Article and Find Full Text PDFDesign and development of a piezoelectric polyvinylidene fluoride (PVDF) thin film based nasal sensor to monitor human respiration pattern (RP) from each nostril simultaneously is presented in this paper. Thin film based PVDF nasal sensor is designed in a cantilever beam configuration. Two cantilevers are mounted on a spectacle frame in such a way that the air flow from each nostril impinges on this sensor causing bending of the cantilever beams.
View Article and Find Full Text PDFOur study explored whether a simple, cost-effective intervention directed only at physicians could improve patient comprehension with informed consent process. In our medical university oncology clinic, we performed a baseline survey on 69 patients receiving new therapy, testing for comprehension of the important components of the informed consent process. We then instituted a three-part intervention, including (1) physician education, (2) an available toxicity list, and (3) a checklist to ensure physician compliance.
View Article and Find Full Text PDFScientificWorldJournal
September 2012
Kinetics of Ru (III) catalyzed oxidation of aliphatic ketones such as acetone, ethyl methyl ketone, diethyl ketone, iso-butylmethyl ketone by N-bromosuccinimide in the presence of Hg(II) acetate have been studied in aqueous acid medium. The order of [N-bromosuccinimide] was found to be zero both in catalyzed as well as uncatalyzed reactions. However, the order of [ketone] changed from unity to a fractional one in the presence of Ru (III).
View Article and Find Full Text PDFIndian J Physiol Pharmacol
December 1974