Publications by authors named "Raithel E"

Objectives: This study aimed to assess the diagnostic image quality and compare the knee cartilage segmentation results using a controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA)-accelerated 3D-dual echo steady-state (DESS) research package sequence in the knee.

Materials And Methods: A total of 64 subjects underwent both two- and fourfold CAIPIRINHA-accelerated 3D-DESS and DESS without parallel acceleration technique of the knee on a 3.0 T system.

View Article and Find Full Text PDF

Objective: To evaluate the repeatability of cartilage volume and thickness values at 1.5 T MRI using a fully automatic cartilage segmentation method and reproducibility of the method between 1.5 T and 3 T data.

View Article and Find Full Text PDF

Background: Detection of rotator cuff tears, a common cause of shoulder disability, can be time-consuming and subject to reader variability. Deep learning (DL) has the potential to increase radiologist accuracy and consistency.

Purpose: The aim of this study was to develop a prototype DL model for detection and classification of rotator cuff tears on shoulder magnetic resonance imaging into no tear, partial-thickness tear, or full-thickness tear.

View Article and Find Full Text PDF

Background: The differential effects of various exercises on knee joint injury have not been well documented. Improper physical training can cause irreversible damage to the knee joint. MRI is generally used to precisely analyze morphological and biochemical changes in the knee cartilage.

View Article and Find Full Text PDF

Background: The cartilage segmentation algorithms make it possible to accurately evaluate the morphology and degeneration of cartilage. There are some factors (location of cartilage subregions, hydrarthrosis and cartilage degeneration) that may influence the accuracy of segmentation. It is valuable to evaluate and compare the accuracy and clinical value of volume and mean T2* values generated directly from automatic knee cartilage segmentation with those from manually corrected results using prototype software.

View Article and Find Full Text PDF

Objective: Assessment of vessel walls is an integral part in diagnosis and disease monitoring of vascular diseases such as vasculitis. Vessel wall imaging (VWI), in particular of intracranial arteries, is the domain of Magnetic Resonance Imaging (MRI) - but still remains a challenge. The tortuous anatomy of intracranial arteries and the need for high resolution within clinically acceptable scan times require special technical conditions regarding the hardware and software environments.

View Article and Find Full Text PDF

Objectives: Vessel wall enhancement (VWE) may be commonly seen on MRI images of asymptomatic subjects. This study aimed to characterize the VWE of the proximal internal carotid (ICA) and vertebral arteries (VA) in a non-vasculitic elderly patient cohort.

Methods: Cranial MRI scans at 3 Tesla were performed in 43 patients (aged ≥ 50 years) with known malignancy for exclusion of cerebral metastases.

View Article and Find Full Text PDF

In patients with CSF rhinorrhea, accurate identification of the CSF leakage site is crucial for surgical planning. We describe the application of a novel gadolinium-enhanced high-resolution 3D compressed-sensing T1 SPACE technique for MR cisternography and compare findings with CT cisternography and intraoperative results. In our pilot experience with 7 patients, precise detection of CSF leaks was feasible using compressed-sensing T1 SPACE, which appeared to be superior to CT cisternography.

View Article and Find Full Text PDF

Purpose: To determine the reproducibility of the automatic cartilage segmentation method using a prototype KneeCaP software (version 1.3; Siemens Healthcare, Erlangen, Germany) and to compare the difference in cartilage volume (CV) between the normal knee joint and knee osteoarthritis (KOA) of different degrees by using the above software.

Materials And Methods: The study included 62 subjects with knee OA and 29 healthy control subjects.

View Article and Find Full Text PDF

Objective: The goal of this study was to assess the reproducibility of an automated knee cartilage segmentation of 21 cartilage regions with a model-based algorithm and to compare the results with manual segmentation.

Design: Thirteen patients with low-grade femoral cartilage defects were included in the study and were scanned twice on a 7-T magnetic resonance imaging (MRI) scanner 8 days apart. A 3-dimensional double-echo steady-state (3D-DESS) sequence was used to acquire MR images for automated cartilage segmentation, and T2-mapping was performed using a 3D triple-echo steady-state (3D-TESS) sequence.

View Article and Find Full Text PDF

Background And Purpose: In vasculopathies of the central nervous system, reliable and timely diagnosis is important against the background of significant morbidity and sequelae in cases of incorrect diagnosis or delayed treatment. Magnetic resonance imaging (MRI) plays a major role in the detection and monitoring of intracranial and extracranial vascular pathologies of different etiologies, in particular for evaluation of the vessel wall in addition to luminal information, thus allowing differentiation between various vasculopathies. Compressed-sensing black-blood MRI combines high image quality with relatively short acquisition time and offers promising potential in the context of neurovascular vessel wall imaging in clinical routine.

View Article and Find Full Text PDF

Background: 3D non-contrast high-resolution black-blood cardiovascular magnetic resonance (CMR) (DANTE-SPACE) has been used for surveillance of abdominal aortic aneurysm (AAA) and validated against computed tomography (CT) angiography. However, it requires a long scan time of more than 7 min. We sought to develop an accelerated sequence applying compressed sensing (CS-DANTE-SPACE) and validate it in AAA patients undergoing surveillance.

View Article and Find Full Text PDF

Background: Changes in muscle fat composition as for example observed in sarcopenia, affect physical performance and muscular function, like strength and power.

Objectives: The purpose of this study was to compare 6-point Dixon magnetic resonance imaging and multi-echo magnetic resonance spectroscopy sequences to quantify muscle fat. Setting, participants and measurements: Two groups were recruited (G1: 23 healthy young men (28 ± 4 years), G2: 56 men with sarcopenia (80 ± 5 years)).

View Article and Find Full Text PDF

Background: Rapid volumetric imaging protocols could better utilize limited scanner resources.

Purpose: To develop and validate an optimized 6-minute high-resolution volumetric brain MRI examination using Wave-CAIPI encoding.

Study Type: Prospective.

View Article and Find Full Text PDF

Background: Changes in muscle fat composition as for example observed in sarcopenia or muscular dystrophy affect physical performance and muscular function, like strength and power. The purpose of the present study is to measure the repeatability of Dixon magnetic resonance imaging (MRI) for assessing muscle volume and fat in the thigh. Furthermore, repeatability of magnetic resonance spectroscopy (MRS) for assessing muscle fat is determined.

View Article and Find Full Text PDF

Background: Ten-minute MRI of the pediatric knee can add value through increased cost-effectiveness and decreased sedation needs but requires validation of its clinical efficacy.

Purpose: To determine the arthroscopy-based diagnostic accuracy and interreader reliability of 10-min 3D Controlled Aliasing In Parallel Imaging Results In Higher Acceleration (CAIPIRINHA) turbo spin echo (TSE) MRI with two isotropic pulse sequences for the diagnosis of internal derangement in children with painful knee conditions.

Study Type: Prospective.

View Article and Find Full Text PDF

Objectives: The aim of this study was to test the hypothesis that magnetic resonance imaging (MRI) of the knee with 10-minute 3-dimensional (3D) controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) sampling perfection with application optimized contrast using different flip angle evolutions (SPACE) turbo spin echo (TSE) protocols can replace 20-minute 2-dimensional (2D) TSE standard-of-reference protocols for the diagnosis of internal derangement.

Materials And Methods: After internal review board approval and prospective informed consent, 100 symptomatic subjects underwent MRI of the knee at 3 T and 50 symptomatic subjects at 1.5 T, consisting of 10-minute 3D CAIPIRINHA SPACE TSE and 20-minute standard-of-reference 2D TSE protocols.

View Article and Find Full Text PDF

Objectives: To test the hypothesis that MRI of the ankle with a 10-min 3D CAIPIRINHA SPACE TSE protocol is at least equivalent for the detection of painful conditions when compared to a 20-min 2D TSE standard of reference protocol.

Methods: Following institutional review board approval and informed consent, 70 symptomatic subjects underwent 3T MRI of the ankle. Six axial, sagittal and coronal intermediate-weighted (IW) and fat-saturated T2-weighted (T2FS) 2D TSE (total acquisition time, 20 min), and two sagittal isotropic IW and T2FS 3D CAIPIRINHA TSE (10 min) pulse sequence prototypes were obtained.

View Article and Find Full Text PDF

Background And Purpose: High-resolution T2-weighted sequences are frequently used in magnetic resonance imaging (MRI) studies to assess the cerebellopontine angle and internal auditory canal (IAC) in sensorineural hearing loss patients but have low yield and lengthened examinations. Because image content in the Wavelet domain is sparse, compressed sensing (CS) that uses incoherent undersampling of k-space and iterative reconstruction can accelerate MRI acquisitions. We hypothesized that an accelerated CS T2 Sampling Perfection with Application optimized Contrasts using different flip angle Evolution (SPACE) sequence would produce acceptable diagnostic quality for IAC screening protocols.

View Article and Find Full Text PDF

The purpose of this study is to evaluate and compare 2-point (2pt), 3-point (3pt), and 6-point (6pt) Dixon magnetic resonance imaging (MRI) sequences with flexible echo times (TE) to measure proton density fat fraction (PDFF) within muscles. Two subject groups were recruited (G1: 23 young and healthy men, 31 ± 6 years; G2: 50 elderly men, sarcopenic, 77 ± 5 years). A 3-T MRI system was used to perform Dixon imaging on the left thigh.

View Article and Find Full Text PDF

Purpose: To prospectively evaluate a prototypical 3D turbo-spin-echo proton-density-weighted sequence with compressed sensing and free-stop scan mode for preventing motion artefacts (3D-PD-CS-SPACE free-stop) for knee imaging in a clinical setting.

Methods And Materials: 80 patients underwent 3T magnetic resonance imaging (MRI) of the knee with our 2D routine protocol and with 3D-PD-CS-SPACE free-stop. In case of a scan-stop caused by motion (images are calculated nevertheless) the sequence was repeated without free-stop mode.

View Article and Find Full Text PDF

Objectives: To assess high-bandwidth and compressed sensing-(CS)-SEMAC turbo spin echo (TSE) techniques for metal artifact reduction MRI of total ankle arthroplasty (TAA) implants.

Methods: Following institutional approval and consent, 40 subjects with TAA implants underwent 1.5-T MRI prospectively.

View Article and Find Full Text PDF

Objective: Develop and optimize an accelerated, high-resolution (0.5 mm isotropic) 3D black blood MRI technique to reduce scan time for whole-brain intracranial vessel wall imaging.

Materials And Methods: A 3D accelerated T-weighted fast-spin-echo prototype sequence using compressed sensing (CS-SPACE) was developed at 3T.

View Article and Find Full Text PDF

Objectives: The aims of this study were to prospectively evaluate image quality, duct visibility, and diagnostic performance in duct-related pathologies of compressed-sensing (CS) accelerated 3-dimensional (3D) magnetic resonance cholangiopancreatography (MRCP) prototype protocols and compare these with those of conventional 3D MRCP protocol in patients with suspected pancreatic diseases.

Material And Methods: The institutional review board approved this prospective study and all patients provided written informed consent. A total of 80 patients (47 men and 33 women; median age, 57 years; age range, 24-87 years) underwent 3D MRCP at 3.

View Article and Find Full Text PDF

Background: Interventional magnetic resonance imaging (MRI) at 3T benefits from higher spatial and temporal resolution, but artifacts of metallic instruments are often larger and may obscure target structures.

Purpose: To test that compressed sensing (CS) slice-encoding metal artifact correction (SEMAC) is feasible for 3T interventional MRI and affords more accurate instrument visualization than turbo spin echo (TSE) and gradient echo (GRE) techniques, and facilitates faster data acquisition than conventional SEMAC.

Study Type: Prospective.

View Article and Find Full Text PDF